Forced Draft (FD) Fan · designed and built in Chennai

Forced Draft (FD) Fan for Waste Incinerators

The FD fan on a waste incinerator is the combustion air fan. Depending on the incinerator type it supplies primary air under a grate or into a kiln or primary chamber, secondary air to the afterburning zone, or fluidising air to a sand bed. On most types it handles ambient air; on large grate plants it often draws air from the waste bunker to control odour.

Send your duty pointCall +91 91766 67102
Ambient, 25 to 45°CAir temperature at the fan
1.13 kg/m³Air density at 40°C
Backward curved for primary airBlade form

How waste incinerators work

Waste incinerators vary with the waste. Municipal solid waste burns on moving grates; hazardous solids, sludges and drums go to rotary kilns; biomedical and small institutional waste to controlled-air two-chamber units; sewage and ETP sludge to fluidised beds; and liquid or solvent wastes to liquid injection chambers. Almost all have a secondary combustion zone held at about 850 to 1,100°C with around two seconds residence time, followed by a waste heat boiler or a quench, then gas cleaning: dry or semi-dry lime and activated carbon injection with a bag filter, a wet scrubber, or both. The ID fan sits at the end of this train, and FD fans supply primary and secondary combustion air.

Where the FD fan sits

  1. Air intake
  2. FD fan
  3. Air preheater
  4. Primary air ducts
  5. Secondary air nozzles
  6. Combustion chambers

Primary air fans sit near the furnace and deliver air under the grate, into the kiln hood or into the primary chamber, through an air preheater on larger plants. A separate secondary air fan supplies nozzles in the afterburning zone at higher pressure for mixing. Fluidised bed units use a high-pressure fluidising air blower instead. Required pressure ranges from about 100 to 250 mmWC for grates and two-chamber units, to 1,500 mmWC or more for fluidised beds.

Air at the FD fan

Air temperature at the fanAmbient, 25 to 45°C
Air after the preheaterUp to 150 to 250°C on wet-waste grate plants, downstream of the fan
DustBunker dust, odour and moisture where air is drawn from the waste bunker
Pressure at the fan outlet100 to 250 mmWC for grates; 300 to 600 mmWC for secondary air; 1,500 mmWC or more for fluid beds
Load profileFollows waste feed and calorific value, which can change quickly
Density at the design temperatureAbout 1.13 kg/m³ at 40°C, 94% of standard air. Pressure developed and power drawn scale with density, so the fan is selected at this condition and the motor is checked at the coldest operating or start-up condition.

FD Fan selection for waste incinerators

Blade formBackward curved for primary air; high-pressure radial or backward curved for secondary and fluidising air
Material of constructionMild steel; coated or stainless steel where bunker air is humid and acidic
Drive and arrangementDirect coupled or direct mounted
Bearings and coolingStandard pedestal or motor bearings
Flow controlVariable speed drive on the combustion control loop with oxygen and temperature trim
Also specifiedInlet screen, airflow measurement and silencer

What this FD fan has to cope with

Changing calorific value

Waste calorific value can change from one charge to the next. If combustion air cannot follow, CO spikes and secondary chamber temperature falls below the regulatory minimum. Airflow measurement and a fast drive tied to oxygen and temperature control keep combustion within limits.

Corrosion from bunker air

Air drawn from the waste bunker is humid and contains organic acids and odour compounds. Coated or stainless steel construction and an inlet screen protect the fan where bunker extraction is used.

Secondary air mixing

Poor mixing in the afterburning zone leaves pockets of unburnt gas. The secondary air fan must deliver enough pressure for high nozzle velocity across the full turndown, which often means a separate high-pressure fan rather than a branch from the primary air fan.

Energy and control

Combustion air demand follows the waste feed and its calorific value. Variable speed drives on primary and secondary air fans, with oxygen trim, reduce fan power and also reduce flue gas volume, which in turn lowers ID fan power and reagent use in the gas cleaning train. On fluidised bed units the fluidising blower is the largest air-side load, and its efficiency at the normal operating point deserves attention.

ID fan and FD fan in waste incinerators

ID fanFD fan
PositionEnd of the gas cleaning train, before the stackAhead of the combustion chambers
What it handlesCleaned flue gas, dry or saturatedAmbient or bunker air
Temperature at the fan140 to 200°C dry, 60 to 80°C wetAmbient, 25 to 45°C
Main design concernCorrosion and high system resistanceFollowing changing waste calorific value
ControlFurnace pressureOxygen and chamber temperature

See also the Induced Draft (ID) Fan for waste incinerators.

Questions buyers ask

What is the difference between primary and secondary air on an incinerator?

Primary air is supplied to the burning waste, under the grate, into the kiln or into the primary chamber, often sub-stoichiometric. Secondary air is injected at high velocity into the afterburning zone to complete combustion of gases and meet CO and residence time requirements.

Does the FD fan on a waste incinerator handle hot gas?

No. It handles ambient air, or air drawn from the waste bunker on larger grate plants. Air preheating, where used for wet waste, happens downstream of the fan, so the fan is sized at ambient density and built in mild steel or coated steel.

Why do fluidised bed incinerators need a high-pressure FD fan?

The air must pass through the distributor and support the weight of the sand bed. This typically needs 1,500 mmWC or more at the fan, far more than a grate or two-chamber incinerator.

Information needed to quote an FD fan for waste incinerators

  1. Duty point. Combustion air quantity in m³/h or kg/h and the static pressure at the fan outlet, with the margins you want.
  2. Air condition. Site ambient temperature range and altitude, and whether the fan takes ambient air or air already heated.
  3. System. Boiler or furnace capacity and fuel, resistance of the air heater, windbox, grate or burner, and the existing fan curve or nameplate if this is a replacement.
  4. Mechanical. Drive arrangement, flow control (damper, inlet vanes or variable speed drive), noise limit, rotation and discharge orientation.
  5. Air split. Primary, secondary and any fluidising air flows and pressures.
  6. Air source. Whether air is drawn from the waste bunker or from outside.

Built and tested in Chennai

Adroit Fantech Engineers has designed and manufactured industrial fans at Ayanambakkam, Chennai since 2004. Each impeller, casing and shaft is built for the gas and temperature it will see, performance tested as per IS 4894 or BS 848 Part I, and balanced to grade G 6.3 or G 2.5 as per ISO 21940-11, with the records supplied with the fan. We also replace rotors and retrofit existing fans of any make.

FD Fan for related applications

Industries

Services on this fan

FD Fan for waste incinerators: send us your duty point

Flow, pressure, air temperature and the fuel are enough to start a selection.

Get a quote