Forced Draft (FD) Fan for API Process Residue Incinerators

The FD fan on an API process residue incinerator is the combustion air fan. It supplies air to the primary chamber or kiln, to liquid residue nozzles and to the secondary chamber. It handles ambient air, and its job is to keep oxygen in hand when tarry or solvent-rich residues release heat faster than expected.

Send your duty pointCall +91 91766 67102
Ambient, 25 to 45°CAir temperature at the fan
1.13 kg/m³Air density at 40°C
Backward curved or high-pressure radialBlade form

How API process residue incinerators work

API manufacturing leaves process residues that are neither clean solvents nor ordinary solid waste: distillation still bottoms, tarry residues, spent carbon and filter aids, salt cakes from neutralisation and off-specification intermediates. Captive incinerators at API sites burn these in a static hearth, a small rotary kiln or a combined chamber with liquid injection for pumpable residues, followed by a secondary chamber at 1,100°C or more. The residues often contain nitrogen, sulphur, chlorine, bromine and fluorine, and some carry spent catalyst metals. Gas is quenched, scrubbed in a venturi and packed alkali column, passed through a mist eliminator and drawn by the ID fan. Combustion air fans serve the primary and secondary chambers.

Where the FD fan sits

  1. Inlet filter
  2. FD fan
  3. Air header
  4. Primary chamber air
  5. Secondary chamber air
  6. Chambers

The fan sits beside the incinerator, feeding a header with branches to the primary chamber or kiln, the liquid residue burner and the secondary chamber. It works against burner and port resistance, typically 250 to 500 mmWC. On many pharma sites the incinerator is close to solvent storage, so the fan and motor are selected for the hazardous area classification and the intake is taken from a safe area.

Air at the FD fan

Air temperature at the fanAmbient, 25 to 45°C
Air at the chambersAmbient on most plants
DustClean air; filtered inlet on pharma sites
Pressure at the fan outletTypically 250 to 500 mmWC
Load profilePeaks after each batch charge of residue
Density at the design temperatureAbout 1.13 kg/m³ at 40°C, 94% of standard air. Pressure developed and power drawn scale with density, so the fan is selected at this condition and the motor is checked at the coldest operating or start-up condition.

FD Fan selection for API process residue incinerators

Blade formBackward curved or high-pressure radial
Material of constructionMild steel; coated against acid vapours in the site atmosphere
Drive and arrangementDirect mounted or direct coupled, flameproof motor where required
Bearings and coolingStandard pedestal or motor bearings
Flow controlVariable speed drive with branch dampers, trimmed on oxygen
Also specifiedAirflow measurement, air pressure interlock and inlet filter

What this FD fan has to cope with

Oxygen loss after charging

A charge of solvent-wet residue can release volatiles faster than the air supply can burn them. Combustion air must increase quickly, so a drive tied to oxygen measurement and margin on the fan are needed.

Secondary chamber cooling

Excess air after the volatiles have burnt off cools the secondary chamber below its required temperature and raises support fuel use. Separate branch control lets the operator reduce secondary chamber air independently of the primary chamber, holding temperature through the burnout phase.

Site atmosphere corrosion

Acid vapours from process vents and scrubbers on chemical sites corrode unprotected fans inside and out. A coated casing and impeller, and an intake located away from process vents, extend fan life.

Energy and control

The combustion air fan is small, but excess air from it raises support fuel use and the gas volume that the quench, scrubber and ID fan must handle. Oxygen trim and a variable speed drive keep excess air low between charges and raise it only when a fresh charge releases volatiles, which suits the batch feeding pattern of most API residue incinerators.

ID fan and FD fan in API process residue incinerators

ID fanFD fan
PositionAfter the alkali scrubberBeside the incinerator, feeding all chambers
What it handlesSaturated gas with HCl, HBr and HFAmbient combustion air
Temperature at the fan60 to 80°CAmbient, 25 to 45°C
Main design concernMixed halogen corrosionOxygen after batch charging
ControlChamber pressureOxygen and chamber temperature

See also the Induced Draft (ID) Fan for API process residue incinerators.

Questions buyers ask

What does the combustion air fan do on an API waste incinerator?

It supplies the air for burning residues in the primary chamber and for completing combustion in the secondary chamber, and air to any liquid residue burner. It handles ambient air.

Why does an API residue incinerator smoke after charging?

Volatile residues release gas faster than the air supply can burn it, so the chamber runs short of oxygen. More combustion air at the moment of charging, faster control on oxygen, or smaller and more frequent charges usually solve it.

Does the FD fan need a flameproof motor?

It depends on the area classification at the fan location. Pharma incinerators are often near solvent storage, so this needs to be checked against the site's hazardous area drawing.

Information needed to quote an FD fan for API process residue incinerators

  1. Duty point. Combustion air quantity in m³/h or kg/h and the static pressure at the fan outlet, with the margins you want.
  2. Air condition. Site ambient temperature range and altitude, and whether the fan takes ambient air or air already heated.
  3. System. Boiler or furnace capacity and fuel, resistance of the air heater, windbox, grate or burner, and the existing fan curve or nameplate if this is a replacement.
  4. Mechanical. Drive arrangement, flow control (damper, inlet vanes or variable speed drive), noise limit, rotation and discharge orientation.
  5. Air branches. Design air flows to primary chamber, residue burner and secondary chamber.
  6. Area classification. Hazardous area zone at the fan location, if any.

Built and tested in Chennai

Adroit Fantech Engineers has designed and manufactured industrial fans at Ayanambakkam, Chennai since 2004. Each impeller, casing and shaft is built for the gas and temperature it will see, performance tested as per IS 4894 or BS 848 Part I, and balanced to grade G 6.3 or G 2.5 as per ISO 21940-11, with the records supplied with the fan. We also replace rotors and retrofit existing fans of any make.

FD Fan for related applications

Industries

Services on this fan

FD Fan for API process residue incinerators: send us your duty point

Flow, pressure, air temperature and the fuel are enough to start a selection.