Forced Draft (FD) Fan for Poultry Waste Incinerators

The FD fan on a poultry waste incinerator is the combustion air blower. It supplies limited air to the primary chamber, where wet waste dries and gasifies, and excess air to the secondary chamber. It handles ambient air, and the key requirement is low air velocity in the primary chamber so that feathers and fine ash are not lifted.

Send your duty pointCall +91 91766 67102
Ambient, 25 to 45°CAir temperature at the fan
1.13 kg/m³Air density at 40°C
Backward curvedBlade form

How poultry waste incinerators work

Poultry waste incinerators handle farm mortalities, hatchery waste such as unhatched eggs, shells and dead chicks, and processing plant offal and feathers. Small farm units are batch-loaded two-chamber incinerators. Larger units at hatcheries and processing plants are often continuously fed by ram or screw into a primary chamber at about 800°C, with a secondary chamber at about 1,000°C. The waste is wet and fatty, and eggshell adds calcium carbonate, so the ash is lime-rich. Feathers and down are light and entrained easily. Gas leaves the secondary chamber, is cooled in a heat exchanger or by tempering air, passes a cyclone and sometimes a bag filter, and the ID fan delivers it to the stack. A combustion air blower supplies both chambers.

Where the FD fan sits

  1. Inlet screen
  2. FD fan
  3. Air header
  4. Primary chamber ports
  5. Secondary air nozzles
  6. Chambers

The blower sits beside the incinerator and feeds a header with branches to the primary and secondary chambers. Air to the primary chamber is spread across many low-velocity ports so that it does not lift the light waste, while secondary air enters through fewer higher-velocity nozzles for mixing. The blower works against typically 120 to 300 mmWC. Its inlet is screened and placed away from poultry houses and waste handling.

Air at the FD fan

Air temperature at the fanAmbient, 25 to 45°C
Air at the chambersAmbient; preheated in some heat recovery designs
DustFeathers, dust and odour in farm air; inlet screen needed
Pressure at the fan outletTypically 120 to 300 mmWC
Air splitPrimary chamber sub-stoichiometric; secondary chamber excess air
Density at the design temperatureAbout 1.13 kg/m³ at 40°C, 94% of standard air. Pressure developed and power drawn scale with density, so the fan is selected at this condition and the motor is checked at the coldest operating or start-up condition.

FD Fan selection for poultry waste incinerators

Blade formBackward curved, compact
Material of constructionMild steel, painted or galvanised for farm humidity and ammonia
Drive and arrangementDirect mounted on the motor shaft
Bearings and coolingMotor bearings
Flow controlBranch dampers and variable speed drive on chamber temperatures
Also specifiedInlet screen and air pressure switch interlock

What this FD fan has to cope with

Feather lift from high primary air

High air velocity in the primary chamber carries feathers and ash out before they burn. Spreading primary air over more ports and controlling it to the gasification need limit carry-over.

Ammonia and humidity corrosion

Farm air contains ammonia and moisture from the poultry houses, and both corrode unprotected steel inside and outside the fan. Galvanised or coated construction, and an air intake taken from a clean, dry area away from the houses and manure stores, extend fan life considerably.

Inlet blockage

Feathers, down and dust from waste handling collect on inlet screens and reduce airflow, which leads to incomplete combustion and smoke. A generous screen area, an intake located away from the feed hopper and a simple daily cleaning routine prevent this.

Energy and control

The combustion air blower is small, but the air split between the chambers has a direct effect on support fuel use and on how much ash and feather char reaches the ID fan. Keeping primary air low for gasification and controlling secondary air on oxygen avoids overcooling the chambers. A variable speed drive suits continuously fed units, where the feed rate follows the farm or plant waste through the day.

ID fan and FD fan in poultry waste incinerators

ID fanFD fan
PositionAfter heat exchanger and cycloneBeside the incinerator, feeding both chambers
What it handlesHot gas with feather char and lime-rich ashAmbient combustion air
Temperature at the fan200 to 260°C, up to 350°C upsetAmbient, 25 to 45°C
Main design concernDust and sticky depositsLow primary velocity to limit carry-over
ControlPrimary chamber pressureChamber temperatures and oxygen

See also the Induced Draft (ID) Fan for poultry waste incinerators.

Questions buyers ask

How is combustion air supplied in a poultry incinerator?

A blower supplies limited air to the primary chamber, where waste dries and gasifies, and excess air to the secondary chamber, where gases burn completely. Burners have their own integral blowers.

Why is low air velocity needed in the primary chamber?

Feathers and fine ash lift very easily. High air velocity carries them out of the primary chamber before they burn, which raises particulate emissions and adds to the deposits that build up on the cyclone and the ID fan.

What material is used for the combustion air blower on a poultry farm?

Galvanised or coated mild steel is common, because farm air contains ammonia and humidity that corrode bare steel. The blower handles ambient air only, so heat or acid resistance is not needed; the ID fan is where those matter.

Information needed to quote an FD fan for poultry waste incinerators

  1. Duty point. Combustion air quantity in m³/h or kg/h and the static pressure at the fan outlet, with the margins you want.
  2. Air condition. Site ambient temperature range and altitude, and whether the fan takes ambient air or air already heated.
  3. System. Boiler or furnace capacity and fuel, resistance of the air heater, windbox, grate or burner, and the existing fan curve or nameplate if this is a replacement.
  4. Mechanical. Drive arrangement, flow control (damper, inlet vanes or variable speed drive), noise limit, rotation and discharge orientation.
  5. Air ports. Primary and secondary air port layout and design flows.
  6. Site air. Location of the air intake relative to poultry houses and waste handling.

Built and tested in Chennai

Adroit Fantech Engineers has designed and manufactured industrial fans at Ayanambakkam, Chennai since 2004. Each impeller, casing and shaft is built for the gas and temperature it will see, performance tested as per IS 4894 or BS 848 Part I, and balanced to grade G 6.3 or G 2.5 as per ISO 21940-11, with the records supplied with the fan. We also replace rotors and retrofit existing fans of any make.

FD Fan for related applications

Industries

Services on this fan

FD Fan for poultry waste incinerators: send us your duty point

Flow, pressure, air temperature and the fuel are enough to start a selection.