13, Galaxy Road, Ponniamman Nagar, Ayanambakkam, Chennai 600 095 +91 91766 67102  |  +91 91766 67103  |  marketing@adroitfantech.com
Home › Applications › FD Fan › Pharmaceutical Solvent Incinerators

Forced Draft (FD) Fan · designed and built in Chennai

Forced Draft (FD) Fan for Pharmaceutical Solvent Incinerators

The FD fan on a pharmaceutical solvent incinerator is the combustion air fan for the solvent burner. It handles ambient air, and because high calorific solvents need a lot of air per kilogram, it must follow sudden changes in solvent flow and composition quickly to avoid smoke and CO.

Send your duty pointCall +91 91766 67102
Ambient, 25 to 45°CAir temperature at the fan
1.13 kg/m³Air density at 40°C
Backward curved for efficiency and a stable curveBlade form

How pharmaceutical solvent incinerators work

Pharmaceutical plants generate spent solvents that cannot be recovered economically: mixtures of methanol, toluene, acetone, IPA, ethyl acetate, DMF and chlorinated solvents such as dichloromethane. These have a high calorific value, often 5,000 to 8,000 kcal/kg, so a solvent incinerator usually burns them with little or no support fuel and recovers the heat in a waste heat boiler raising steam for the site. The chamber is held at 1,100°C or more with two seconds residence time where halogenated solvent exceeds about 1% chlorine. Gas leaves the boiler at about 220 to 280°C, is quenched to saturation and scrubbed with caustic, and the ID fan pulls it through to the stack. A combustion air fan feeds the solvent burner.

Where the FD fan sits

  1. Inlet filter
  2. FD fan
  3. Air preheater
  4. Burner windbox
  5. Solvent burner
  6. Combustion chamber

The fan sits near the burner and delivers ambient air to the windbox, through an air preheater on some plants. It works against the burner swirl register and windbox, typically 300 to 600 mmWC. Because the site handles flammable solvents, the fan location and motor rating are set by the hazardous area classification, and the inlet is taken from outside any classified zone where possible.

Air at the FD fan

Air temperature at the fanAmbient, 25 to 45°C
Air after the preheaterUp to 200 to 250°C where fitted, downstream of the fan
DustClean air; filtered inlet on pharma sites
Pressure at the fan outletTypically 300 to 600 mmWC
Hazardous areaFan and motor may sit in a classified zone near solvent storage
Density at the design temperatureAbout 1.13 kg/m³ at 40°C, 94% of standard air. Pressure developed and power drawn scale with density, so the fan is selected at this condition and the motor is checked at the coldest operating or start-up condition.

FD Fan selection for pharmaceutical solvent incinerators

Blade formBackward curved for efficiency and a stable curve
Material of constructionMild steel; non-sparking features where the area classification calls for them
Drive and arrangementDirect mounted or direct coupled, with a flameproof motor where required
Bearings and coolingStandard pedestal or motor bearings
Flow controlVariable speed drive on air-fuel ratio with oxygen trim
Also specifiedAirflow measurement, air pressure switch interlock, and inlet filter

What this FD fan has to cope with

Air shortage on high calorific solvent

A change from aqueous waste to a pure solvent can double the air demand in seconds. If the fan cannot respond, the chamber produces soot and CO. Measured airflow and a drive tuned to lead fuel on rising load prevent this.

Flame instability on mixed feeds

Solvent blends with water or halogens burn less easily. The fan must deliver steady pressure at low flow to keep the swirl stable when the burner turns down.

Ignition source near solvents

Fans close to solvent handling can be an ignition source. Fan and motor are selected for the area classification, and the air intake is taken from a safe location.

Energy and control

With a waste heat boiler, every percent of excess air carries heat to the stack and reduces steam output. A variable speed FD fan with oxygen trim holds excess air at the lowest stable level, saving fuel equivalent and fan power, and reducing gas volume through the boiler, scrubber and ID fan.

ID fan and FD fan in pharmaceutical solvent incinerators

ID fanFD fan
PositionAfter the caustic scrubberAt the burner windbox
What it handlesSaturated gas with HCl and chlorineAmbient combustion air
Temperature at the fan55 to 75°CAmbient, 25 to 45°C
Main design concernChlorine and chloride corrosionFast response to solvent changes
ControlChamber pressureAir-fuel ratio with oxygen trim

See also the Induced Draft (ID) Fan for pharmaceutical solvent incinerators.

Questions buyers ask

What size combustion air fan does a solvent incinerator need?

It depends on the maximum solvent firing rate and its stoichiometric air, plus excess air. Stoichiometric air ranges from roughly 5 Nm³ per kilogram for methanol to about 10 Nm³ for toluene, so the blend matters. We size the fan on the maximum firing case with margin for blend changes.

Does the FD fan need a flameproof motor?

It depends on the hazardous area classification of the fan location. Many pharma solvent incinerators sit near solvent tanks, and the motor and fan are selected to suit the zone.

Why does the incinerator smoke when the solvent changes?

Usually because combustion air does not follow the change in solvent heat input quickly enough, so the burner runs short of air for a few seconds. Airflow measurement, oxygen trim and a fast drive, with air leading fuel on rising load, solve most cases.

Information needed to quote an FD fan for pharmaceutical solvent incinerators

  1. Duty point. Combustion air quantity in m³/h or kg/h and the static pressure at the fan outlet, with the margins you want.
  2. Air condition. Site ambient temperature range and altitude, and whether the fan takes ambient air or air already heated.
  3. System. Boiler or furnace capacity and fuel, resistance of the air heater, windbox, grate or burner, and the existing fan curve or nameplate if this is a replacement.
  4. Mechanical. Drive arrangement, flow control (damper, inlet vanes or variable speed drive), noise limit, rotation and discharge orientation.
  5. Firing range. Minimum and maximum solvent firing rate and calorific value.
  6. Area classification. Hazardous area zone at the fan location, if any.

Built and tested in Chennai

Adroit Fantech Engineers has designed and manufactured industrial fans at Ayanambakkam, Chennai since 2004. Each impeller, casing and shaft is built for the gas and temperature it will see, performance tested as per IS 4894 or BS 848 Part I, and balanced to grade G 6.3 or G 2.5 as per ISO 21940-11, with the records supplied with the fan. We also replace rotors and retrofit existing fans of any make.

FD Fan for related applications

Industries

Services on this fan

FD Fan for pharmaceutical solvent incinerators: send us your duty point

Flow, pressure, air temperature and the fuel are enough to start a selection.

Get a quote