Forced Draft (FD) Fan for Sludge Fluidised Bed Incinerators

The FD fan on a sludge fluidised bed incinerator is the fluidising air blower. It pushes ambient air through the air preheater into the windbox and up through the distributor to fluidise the sand bed. It needs high pressure to support the bed, and that pressure decides its design.

Send your duty pointCall +91 91766 67102
Ambient, 25 to 45°CAir temperature at the fan
1.13 kg/m³Air density at 40°C
High-pressure backward curved or radialBlade form

How sludge fluidised bed incinerators work

Sewage sludge, ETP sludge and paper mill sludge are dewatered to about 20 to 35% dry solids and fed into a bubbling fluidised bed of hot sand at about 750 to 850°C, with the freeboard above at about 850 to 900°C. The water in the sludge evaporates almost at once, so the flue gas carries a very high water vapour content, often 30 to 45% by volume. All the ash leaves with the gas as fine particles, along with some bed sand. The gas passes a gas-to-air heat exchanger that preheats the fluidising air, often a waste heat boiler, then a bag filter or ESP, and usually a wet scrubber. The fluidising air blower is the FD fan, and the ID fan pulls the gas train.

Where the FD fan sits

  1. Inlet filter and silencer
  2. FD fan
  3. Air preheater
  4. Hot windbox
  5. Distributor nozzles
  6. Sand bed

The blower sits at ground level and delivers ambient air to the cold side of the gas-to-air heat exchanger, where it is preheated to typically 500 to 650°C, then into the windbox under the bed. It works against the preheater, distributor nozzles and the weight of the bed, typically 1,500 to 2,500 mmWC. Smaller units without preheaters use start-up burners in the windbox.

Air at the FD fan

Air temperature at the fanAmbient, 25 to 45°C
Air after the preheater500 to 650°C, downstream of the fan
DustClean air; filtered inlet to protect preheater and nozzles
Pressure at the fan outletTypically 1,500 to 2,500 mmWC
Minimum flowMust stay above minimum fluidising velocity at all loads
Density at the design temperatureAbout 1.13 kg/m³ at 40°C, 94% of standard air. Pressure developed and power drawn scale with density, so the fan is selected at this condition and the motor is checked at the coldest operating or start-up condition.

FD Fan selection for sludge fluidised bed incinerators

Blade formHigh-pressure backward curved or radial, single stage or multistage depending on pressure
Material of constructionMild steel; heavier casing for high pressure
Drive and arrangementDirect coupled, arrangement suited to a large motor
Bearings and coolingPedestal bearings; no cooling needed on ambient air
Flow controlVariable speed drive with a minimum flow limit for fluidisation
Also specifiedInlet filter and silencer, non-return damper, and airflow measurement

What this FD fan has to cope with

Loss of fluidisation

If air falls below minimum fluidising velocity, the bed slumps and hot spots form, leading to clinkering. The control system sets a floor on blower flow, and the blower is sized to keep fluidisation at minimum sludge feed.

Backflow of hot sand

When the blower stops, sand can fall back into the distributor nozzles and windbox. A non-return damper and nozzle design that resists backflow prevent this, and restarts follow a set sequence.

Noise

High-pressure blowers are noisy, particularly at the inlet, and sludge plants are often near residential areas or treatment plant staff. An inlet silencer, acoustic lagging on the casing and ducts, and an enclosure where needed bring noise within limits.

Energy and control

The fluidising blower works against high pressure all the time the bed is hot, so it is often the largest auxiliary motor. A variable speed drive holding flow just above the fluidisation minimum, and keeping bed depth at the design value rather than letting it build up with sand and ash, keep power down.

ID fan and FD fan in sludge fluidised bed incinerators

ID fanFD fan
PositionAfter the bag filter, often before the scrubberAhead of the air preheater and windbox
What it handlesHumid flue gas with fine ashAmbient fluidising air
Temperature at the fan160 to 200°CAmbient, 25 to 45°C
Main design concernLarge wet gas volume and dew pointHigh pressure for the bed
ControlFreeboard pressureFluidising flow with minimum limit

See also the Induced Draft (ID) Fan for sludge fluidised bed incinerators.

Questions buyers ask

What pressure does a fluidising air blower need for a sludge incinerator?

Typically 1,500 to 2,500 mmWC at the blower outlet, covering the air preheater, distributor nozzles and the weight of the sand bed. The exact value depends on bed depth and nozzle design.

Does the FD fan handle hot air in a sludge incinerator?

No. It handles ambient air and pushes it through the gas-to-air preheater, where it is heated to around 500 to 650°C before entering the windbox. The hot section starts after the blower, so it is sized at ambient density.

Can the fluidising blower use a VFD?

Yes, with a minimum flow limit in the control system to keep the bed fluidised. The drive lets the blower match the sludge feed rate and bed condition without throttling, which saves considerable power on this high-pressure duty.

Information needed to quote an FD fan for sludge fluidised bed incinerators

  1. Duty point. Combustion air quantity in m³/h or kg/h and the static pressure at the fan outlet, with the margins you want.
  2. Air condition. Site ambient temperature range and altitude, and whether the fan takes ambient air or air already heated.
  3. System. Boiler or furnace capacity and fuel, resistance of the air heater, windbox, grate or burner, and the existing fan curve or nameplate if this is a replacement.
  4. Mechanical. Drive arrangement, flow control (damper, inlet vanes or variable speed drive), noise limit, rotation and discharge orientation.
  5. Bed data. Bed area, depth, sand size and minimum fluidising velocity.
  6. Preheater. Air side pressure drop of the preheater at design flow.

Built and tested in Chennai

Adroit Fantech Engineers has designed and manufactured industrial fans at Ayanambakkam, Chennai since 2004. Each impeller, casing and shaft is built for the gas and temperature it will see, performance tested as per IS 4894 or BS 848 Part I, and balanced to grade G 6.3 or G 2.5 as per ISO 21940-11, with the records supplied with the fan. We also replace rotors and retrofit existing fans of any make.

FD Fan for related applications

Industries

Services on this fan

FD Fan for sludge fluidised bed incinerators: send us your duty point

Flow, pressure, air temperature and the fuel are enough to start a selection.