The FD fan on a plastic pyrolysis plant is the combustion air fan for the reactor heating furnace. It supplies ambient air to burners firing the non-condensable gas and pyrolysis oil. Its design is set by the need to burn a gas whose composition and flow change through each batch.

Send your duty pointCall +91 91766 67102
Ambient, 25 to 45°CAir temperature at the fan
1.13 kg/m³Air density at 40°C
Backward curved for efficiencyBlade form

How plastic pyrolysis plants work

Plastic pyrolysis plants heat shredded waste plastics, mainly polyethylene and polypropylene, in a closed reactor at about 400 to 500°C without air. The plastic cracks into vapours that are condensed to pyrolysis oil, a non-condensable gas, and a small residue of char. Batch plants use a rotating drum reactor; continuous plants use screw or kiln reactors. The reactor is heated externally by a furnace or jacket burning the non-condensable gas, pyrolysis oil, or wood and coal at start-up. The product vapours pass through condensers under slight positive pressure and do not go through a fan. The draft fans serve the heating furnace: a combustion air fan for its burners and an ID fan that draws the furnace flue gas from the reactor jacket to the stack.

Where the FD fan sits

  1. Inlet screen
  2. FD fan
  3. Air preheater
  4. Burner
  5. Heating furnace
  6. Reactor jacket

The fan sits beside the heating furnace and supplies ambient air to the burners, through an air preheater where fitted. It works against burner and duct resistance, typically 150 to 400 mmWC. On plants that use wood or coal at start-up, the fan also supplies air under a small grate. The pyrolysis vapour path has no fan, so this fan affects only the heating side.

Air at the FD fan

Air temperature at the fanAmbient, 25 to 45°C
Air after the preheater150 to 250°C where fitted, downstream of the fan
DustPlastic flakes and dust from feed handling; inlet screen needed
Pressure at the fan outletTypically 150 to 400 mmWC
Load profileChanges through the batch as gas production rises and falls
Density at the design temperatureAbout 1.13 kg/m³ at 40°C, 94% of standard air. Pressure developed and power drawn scale with density, so the fan is selected at this condition and the motor is checked at the coldest operating or start-up condition.

FD Fan selection for plastic pyrolysis plants

Blade formBackward curved for efficiency
Material of constructionMild steel throughout
Drive and arrangementDirect mounted on the motor shaft
Bearings and coolingMotor bearings
Flow controlVariable speed drive or damper, linked to burner firing and oxygen
Also specifiedInlet screen, air pressure interlock with burners

What this FD fan has to cope with

Changing gas composition

The non-condensable gas changes in flow and calorific value as the batch progresses. Fixed air settings produce smoke or excess air. Air control linked to burner firing or flue oxygen keeps combustion clean.

Plastic flakes at the inlet

Light flakes from shredding are drawn into the fan, block the inlet screen and build up on the impeller. Taking air away from the feed area keeps the fan clean.

Backfire risk

Burning a gas of variable composition needs a reliable air supply. A fan trip while gas is still flowing can lead to an unburnt gas build-up in the furnace, so air pressure interlocks close the gas supply at once, and the furnace is purged before relighting.

Energy and control

The combustion air fan is small, but good air control saves heating fuel, which on many plants is the process's own oil. Excess air carries heat out with the flue gas and increases the gas the ID fan must move. A variable speed drive with oxygen trim through the heat-up, reaction and cool-down stages of each batch cuts both fuel and fan power.

ID fan and FD fan in plastic pyrolysis plants

ID fanFD fan
PositionAfter heat recovery and cyclone, at the stackBeside the heating furnace
What it handlesHeating furnace flue gasAmbient combustion air
Temperature at the fan200 to 300°C, up to 450°C upsetAmbient, 25 to 45°C
Main design concernStable draft and sootAir for variable gas
ControlFurnace pressureBurner firing and oxygen

See also the Induced Draft (ID) Fan for plastic pyrolysis plants.

Questions buyers ask

Does the FD fan supply air to the pyrolysis reactor?

No. The reactor runs without air, because air would burn the plastic instead of cracking it. The FD fan supplies combustion air only to the burners in the heating furnace, which heat the reactor from outside.

What fuel do pyrolysis plant burners use?

Usually the non-condensable gas from the process, with pyrolysis oil, diesel, or wood and coal at start-up. The FD fan is sized for the highest air demand among these fuels.

Why does the heating furnace smoke at certain times in the batch?

Gas production and calorific value change through the batch, rising during the main reaction and falling towards the end. If combustion air does not follow these changes, smoke forms. Air control linked to flue oxygen solves most cases.

Information needed to quote an FD fan for plastic pyrolysis plants

  1. Duty point. Combustion air quantity in m³/h or kg/h and the static pressure at the fan outlet, with the margins you want.
  2. Air condition. Site ambient temperature range and altitude, and whether the fan takes ambient air or air already heated.
  3. System. Boiler or furnace capacity and fuel, resistance of the air heater, windbox, grate or burner, and the existing fan curve or nameplate if this is a replacement.
  4. Mechanical. Drive arrangement, flow control (damper, inlet vanes or variable speed drive), noise limit, rotation and discharge orientation.
  5. Burners. Number of burners and fuels, including start-up fuel.
  6. Gas production. Non-condensable gas flow range through the batch.

Built and tested in Chennai

Adroit Fantech Engineers has designed and manufactured industrial fans at Ayanambakkam, Chennai since 2004. Each impeller, casing and shaft is built for the gas and temperature it will see, performance tested as per IS 4894 or BS 848 Part I, and balanced to grade G 6.3 or G 2.5 as per ISO 21940-11, with the records supplied with the fan. We also replace rotors and retrofit existing fans of any make.

FD Fan for related applications

Industries

Services on this fan

FD Fan for plastic pyrolysis plants: send us your duty point

Flow, pressure, air temperature and the fuel are enough to start a selection.

Get a quote