The process
Submerged arc furnaces for ferro manganese, ferro chrome and ferro silicon produce a hot fume dense with very fine oxide dust. Semi-closed furnaces take it through a cooling system to a large bag filter, and the main ID fan on the clean side is a large volume, continuous duty. Waste heat boilers on the furnace off-gas add an ID fan of their own.
The gas
Ferro alloy furnace fume carries very fine silica and metallic dust at high temperature. Fine dust packs into blade roots, so the wheel is chosen to shed it and the fan is placed after the bag filter.
Selection for this process
| Type | Guillotine for isolation, multi louver or butterfly for control, diverter where the gas is switched between two paths |
| Material | Mild steel |
| Sealing | Seal air arrangement where tight shut-off is needed on hot or dusty gas |
Types, construction and performance of the dampers.
Industries
Fans in ferro alloy submerged arc furnaces
Dampers in other processes
Information needed to select or quote
- Gas volume and temperature. Actual flow at the inlet, normal and upset temperature, moisture.
- Dust or pollutant. Inlet loading, particle size distribution, whether it is abrasive, sticky, hygroscopic or combustible; for gases, the species and concentration.
- Required outlet. The emission limit or clean gas concentration the unit must meet.
- Site. Available space and height, material of construction preferences, and how the collected material is to be discharged.