13, Galaxy Road, Ponniamman Nagar, Ayanambakkam, Chennai 600 095 +91 91766 67102  |  +91 91766 67103  |  marketing@adroitfantech.com
Home › Applications › Combustion Air Blower › Ferro Alloy Submerged Arc Furnaces

Combustion Air Blower for Ferro Alloy Submerged Arc Furnaces

Feeds a burner with air at the pressure the burner register needs. In ferro alloy submerged arc furnaces the gas at the fan is submerged arc furnace fume, and that sets the blade form, the material and the drive.

The process

Submerged arc furnaces for ferro manganese, ferro chrome and ferro silicon produce a hot fume dense with very fine oxide dust. Semi-closed furnaces take it through a cooling system to a large bag filter, and the main ID fan on the clean side is a large volume, continuous duty. Waste heat boilers on the furnace off-gas add an ID fan of their own.

The gas at the fan

Ferro alloy furnace fume carries very fine silica and metallic dust at high temperature. Fine dust packs into blade roots, so the wheel is chosen to shed it and the fan is placed after the bag filter.

Selection for this duty

Blade formRadial tipped with wear liners, or straight radial where the dust is coarse
Material of constructionMild steel with replaceable wear liners on the blades and the scroll at the cut-off
Drive and bearingsDirect coupled, shaft cooling disc, bearings in a pedestal outside the gas stream, allowance for thermal growth
Also specifiedHard facing or liners on the blade pressure face
Density at the fanAt about 250°C the gas density is close to 0.67 kg/m³, 56% of standard air. Pressure developed and power drawn fall in the same ratio, so the selection is made at this density and the motor is checked at cold start.

Feeds a burner with air at the pressure the burner register needs. Sized for the burner turndown range, and often fitted with an inlet silencer. Client-stated blade types for the Combustion Air Blower in general: Backward curved and radial tipped.

Industries

Other fans in ferro alloy submerged arc furnaces

Combustion Air Blower in other processes

Information needed to select or quote

  1. Duty point. Volume flow and static pressure at the fan inlet, with the gas density and temperature or the conditions to derive it.
  2. Operating conditions. Site altitude, normal operating temperature and continuous or intermittent duty.
  3. Gas stream. Dust loading and particle size, corrosive species, moisture, upset temperature and any tendency of the material to deposit on the impeller.
  4. Mechanical. Rotation viewed from the drive end, discharge orientation and motor power.

Send us your duty point

Flow, pressure, gas condition and temperature are enough to start a selection.

Get a quote