Forced Draft (FD) Fan for Ceramic Tile Roller Kilns

The FD fan on a ceramic tile roller kiln is the combustion air fan for the burners above and below the rollers. On many modern kilns it takes hot air from the cooling section rather than ambient air. That choice decides its design: a cold-air fan is simple, a hot-air fan needs heat-resisting construction.

Send your duty pointCall +91 91766 67102
Ambient, 25 to 45°C, or 150 to 250°C with cooling section airAir temperature at the fan
1.13 kg/m³Air density at 40°C
Backward curved high-pressureBlade form

How ceramic tile roller kilns work

Floor, wall and vitrified tiles are fired in single-layer roller kilns 100 to 300 m long, with cycles of about 35 to 70 minutes and peak temperatures of 1,150 to 1,220°C. Tiles ride on ceramic rollers through preheating, firing, rapid cooling, slow cooling and final cooling sections. Burners above and below the roller plane fire natural gas, LPG or, in some clusters, producer gas from coal gasifiers. Flue gas moves back towards the entry and is drawn off by the fume exhaust fan, while cooling sections have their own fans. Hot air from the cooling zone is often used for the dryers, and on some kilns as preheated combustion air. Clays release fluorine and sulphur during firing.

Where the FD fan sits

  1. Cooling section hot air or inlet filter
  2. FD fan
  3. Combustion air header
  4. Burner valves
  5. Burners above and below rollers

The fan feeds headers on both sides of the kiln, supplying burners above and below the roller plane along the firing section. Where it takes air from the cooling section, the air enters at 150 to 250°C, saving fuel but increasing the volume and requiring a heat-resistant fan. The fan typically works against 300 to 600 mmWC, including the header, valves and burners.

Air at the FD fan

Air temperature at the fanAmbient, 25 to 45°C, or 150 to 250°C with cooling section air
DustClean ambient air; some fines in recovered cooling air
Pressure at the fan outletTypically 300 to 600 mmWC
Burner countOften over a hundred burners on a large kiln
Density at the design temperatureAbout 1.13 kg/m³ at 40°C, 94% of standard air. Pressure developed and power drawn scale with density, so the fan is selected at this condition and the motor is checked at the coldest operating or start-up condition.

FD Fan selection for ceramic tile roller kilns

Blade formBackward curved high-pressure, with a stable curve
Material of constructionMild steel for ambient air; heat-resisting steel for preheated air
Drive and arrangementDirect coupled
Bearings and coolingStandard bearings; cooling disc and heat shield for preheated air
Flow controlVariable speed drive on header pressure
Also specifiedInlet filter on ambient duty, standby fan on large kilns

What this FD fan has to cope with

Hot air volume and density

With combustion air taken from the cooling section at 200°C, the volume is about 50% more than at ambient, and the fan must be sized for it. A fan selected at ambient density falls short at full firing. The selection is made at the actual air temperature, with a check at cold start when the air is ambient.

Burner balance above and below the rollers

Burners above and below the rollers fire into different spaces, and uneven air supply leads to temperature differences that curl or warp tiles. Separate headers or zone valves for top and bottom burners, fed by a fan with pressure margin, keep each side under control.

Many burners on one fan

On a large kiln, over a hundred burners share one fan. Any instability in its pressure affects them all. A fan with a steadily rising curve, operating at a point well away from the peak, gives the burner controls a reliable supply to work with.

Energy and control

Fuel is by far the largest energy cost on a tile kiln, so the combustion air system is designed around fuel saving. Using hot air from the cooling section reduces fuel considerably, though it increases fan volume. A variable speed drive on header pressure saves fan power, and keeping excess air low at the burners saves fuel and reduces fume volume.

ID fan and FD fan in ceramic tile roller kilns

ID fanFD fan
PositionAt the kiln entry, after the preheating sectionBeside the firing section, feeding burner headers
What it handlesFumes with HF, SO₂ and sometimes tarAmbient or preheated air
Temperature at the fan180 to 250°CAmbient, or 150 to 250°C preheated
Main design concernPressure profile and acid corrosionBurner balance, hot air volume
ControlEntry section pressureHeader pressure

See also the Induced Draft (ID) Fan for ceramic tile roller kilns.

Questions buyers ask

What is the FD fan on a tile roller kiln?

It is the combustion air fan that supplies air to the burners above and below the rollers in the firing section. It can take ambient air or hot air from the cooling section. The cooling and fume exhaust fans are separate machines with their own duties.

Can a tile kiln combustion air fan use hot air from the cooling zone?

Yes, many kilns do this to save fuel. The fan must then be designed for air at 150 to 250°C, with heat-resisting materials, a cooling disc on the shaft and selection at the hot air density. The fan is also checked at ambient air for start-up conditions.

How many burners can one combustion air fan serve on a roller kiln?

One fan commonly serves all the burners on a kiln, often over a hundred. It is sized for the total air at full firing, with headers designed to give even pressure along the kiln. Large kilns sometimes split the burners between two fans for redundancy.

Information needed to quote an FD fan for ceramic tile roller kilns

  1. Duty point. Combustion air quantity in m³/h or kg/h and the static pressure at the fan outlet, with the margins you want.
  2. Air condition. Site ambient temperature range and altitude, and whether the fan takes ambient air or air already heated.
  3. System. Boiler or furnace capacity and fuel, resistance of the air heater, windbox, grate or burner, and the existing fan curve or nameplate if this is a replacement.
  4. Mechanical. Drive arrangement, flow control (damper, inlet vanes or variable speed drive), noise limit, rotation and discharge orientation.
  5. Air source. Whether combustion air is ambient or recovered from the cooling section, and its temperature.
  6. Burner layout. Number of burners above and below the rollers and the required air pressure.

Built and tested in Chennai

Adroit Fantech Engineers has designed and manufactured industrial fans at Ayanambakkam, Chennai since 2004. Each impeller, casing and shaft is built for the gas and temperature it will see, performance tested as per IS 4894 or BS 848 Part I, and balanced to grade G 6.3 or G 2.5 as per ISO 21940-11, with the records supplied with the fan. We also replace rotors and retrofit existing fans of any make.

FD Fan for related applications

Industries

Services on this fan

FD Fan for ceramic tile roller kilns: send us your duty point

Flow, pressure, air temperature and the fuel are enough to start a selection.

Get a quote