Forced Draft (FD) Fan · designed and built in Chennai

Forced Draft (FD) Fan for Refractory Brick Tunnel Kilns

The FD fan on a refractory brick tunnel kiln is the combustion air fan for the side-wall burners. It supplies ambient air at high pressure for burner jets that must reach into dense settings. Most of the combustion air is cooling air flowing forward through the ware, so the fan supplies only part of the total.

Send your duty pointCall +91 91766 67102
Ambient, 25 to 45°CAir temperature at the fan
1.13 kg/m³Air density at 40°C
Backward curved high-pressureBlade form

How refractory brick tunnel kilns work

Fireclay, high alumina, silica and basic bricks such as magnesia and magnesia-chrome are fired in long tunnel kilns at about 1,350 to 1,750°C, depending on the product, with cycles of two to five days. Cars carry dense, heavy settings, often several tonnes per car. Natural gas, furnace oil or producer gas burners fire from the side walls, and the cooling zone air flows forward through the ware as secondary combustion air. Flue gas leaves at the entry end through the preheating zone, carrying moisture and binder residues such as lignosulphonate, which releases SO₂, or tar and pitch from bonded basic bricks. The flue gas exhaust fan is the ID fan, and burner combustion air comes from a separate fan.

Where the FD fan sits

  1. Inlet filter
  2. FD fan
  3. Air header
  4. Burner valves
  5. Side-wall burners

The fan feeds a header along both sides of the firing zone, supplying burners through control valves. The cooling air blown in at the exit end flows forward through the ware, is preheated, and becomes secondary combustion air. The burner air from this fan provides flame momentum and mixing, which must penetrate the dense, tall settings. Fan pressure is typically 400 to 800 mmWC.

Air at the FD fan

Air temperature at the fanAmbient, 25 to 45°C
DustRefractory dust in the plant; filtered inlet needed
Pressure at the fan outletTypically 400 to 800 mmWC
Firing temperature1,350 to 1,750°C depending on product
Density at the design temperatureAbout 1.13 kg/m³ at 40°C, 94% of standard air. Pressure developed and power drawn scale with density, so the fan is selected at this condition and the motor is checked at the coldest operating or start-up condition.

FD Fan selection for refractory brick tunnel kilns

Blade formBackward curved high-pressure, with a stable curve
Material of constructionMild steel
Drive and arrangementDirect coupled
Bearings and coolingStandard pedestal bearings
Flow controlVariable speed drive on header pressure
Also specifiedInlet filter and silencer; standby fan with automatic changeover

What this FD fan has to cope with

Flame penetration into dense settings

Refractory settings are tall and dense, and the burner flame must reach into them to fire the inner bricks evenly. Low burner air pressure gives short, lazy flames and uneven firing. A fan with enough pressure for high-velocity burners, held steady by speed control, ensures good flame penetration.

Refractory dust at the inlet

Refractory plants are dusty from pressing, grinding and handling. Abrasive refractory dust drawn into the fan wears the impeller and bearings. A filtered inlet from a clean area protects the fan and keeps the burner air passages clear. Refractory grog is hard and wears the impeller quickly if it is drawn in.

Loss of combustion air

A fan trip stops firing in a kiln with days of production inside. Uneven cooling can crack bricks and damage the kiln. A standby fan with automatic changeover and a reliable power supply are standard practice, with the changeover tested during planned stops so that it can be trusted when a trip occurs.

Energy and control

Refractory kilns fire at very high temperatures and fuel is the dominant cost. A variable speed drive on header pressure saves fan power, but most savings come from good air-fuel ratio control and from using preheated cooling air as secondary air. Keeping burner air at the minimum needed for flame shape reduces cold air entering the firing zone.

ID fan and FD fan in refractory brick tunnel kilns

ID fanFD fan
PositionAt the kiln entry, after the preheating zoneBeside the firing zone, feeding the burner header
What it handlesFlue gas with SO₂ and tar fumesClean ambient air
Temperature at the fan200 to 300°CAmbient
Main design concernAcid and tar deposits, dense settingsFlame penetration into dense settings
ControlPreheating zone pressureHeader pressure

See also the Induced Draft (ID) Fan for refractory brick tunnel kilns.

Questions buyers ask

What is the FD fan on a refractory tunnel kiln?

It is the combustion air fan that supplies air to the burners along the firing zone. Most of the combustion air comes from the cooling zone, flowing forward through the ware, so the FD fan supplies burner primary air for flame shape and mixing. Separate fans handle cooling air and hot air recovery.

What pressure does a refractory kiln burner fan need?

Typically 400 to 800 mmWC, higher than for most ceramic kilns, because high-velocity burners must drive the flame into dense refractory settings. The duty is taken from the burner maker's data, with header and valve losses and margin for the full firing rate at the highest product temperature.

Should a refractory tunnel kiln have a standby combustion air fan?

Yes. A trip stops firing in a kiln holding days of production and can crack bricks and damage the kiln lining. A standby fan with automatic changeover protects both. The cost of a standby is small compared with a lost kiln load or a damaged lining, and a spare motor alone is not enough because changing it takes too long.

Information needed to quote an FD fan for refractory brick tunnel kilns

  1. Duty point. Combustion air quantity in m³/h or kg/h and the static pressure at the fan outlet, with the margins you want.
  2. Air condition. Site ambient temperature range and altitude, and whether the fan takes ambient air or air already heated.
  3. System. Boiler or furnace capacity and fuel, resistance of the air heater, windbox, grate or burner, and the existing fan curve or nameplate if this is a replacement.
  4. Mechanical. Drive arrangement, flow control (damper, inlet vanes or variable speed drive), noise limit, rotation and discharge orientation.
  5. Burners. Number and type of burners and the air pressure required at each.
  6. Products. Brick types fired and firing temperature.

Built and tested in Chennai

Adroit Fantech Engineers has designed and manufactured industrial fans at Ayanambakkam, Chennai since 2004. Each impeller, casing and shaft is built for the gas and temperature it will see, performance tested as per IS 4894 or BS 848 Part I, and balanced to grade G 6.3 or G 2.5 as per ISO 21940-11, with the records supplied with the fan. We also replace rotors and retrofit existing fans of any make.

FD Fan for related applications

Industries

Services on this fan

FD Fan for refractory brick tunnel kilns: send us your duty point

Flow, pressure, air temperature and the fuel are enough to start a selection.