Forced Draft (FD) Fan for Glass Melting Furnaces

The FD fan on a glass melting furnace is the combustion air fan. On regenerative furnaces it pushes ambient air through the reversing valve into the checkers; on recuperative furnaces it feeds the recuperator. Oxy-fuel furnaces have none. In every case the fan must keep running through reversals and supply cooling air if firing stops.

Send your duty pointCall +91 91766 67102
Ambient, 25 to 45°CAir temperature at the fan
1.13 kg/m³Air density at 40°C
Backward curvedBlade form

How glass melting furnaces work

Glass melting furnaces melt a batch of sand, soda ash, limestone, dolomite and cullet at about 1,450 to 1,600°C in a refractory tank. The main types differ in how they recover heat. Regenerative furnaces, end-port or cross-fired, alternate combustion air and waste gas through checker chambers every 20 to 30 minutes, preheating air to 1,100 to 1,300°C. Recuperative unit melters preheat air to 600 to 800°C in a metallic recuperator. Oxy-fuel furnaces burn with oxygen and need no air preheat. Electric melters and day tanks fill out the range. Fuel is natural gas, LPG, fuel oil or producer gas, often with electric boost. Waste gas leaves the heat recovery at 400 to 800°C and goes to the chimney, or through a waste heat boiler, dry sorbent injection and an ESP or bag filter before an ID fan.

Where the FD fan sits

  1. Inlet filter
  2. FD fan
  3. Reversing valve
  4. Regenerator or recuperator
  5. Ports and burners
  6. Melter

The fan stands near the regenerator or recuperator and blows ambient air into it through a reversing valve or a cold air main. Air pressure needs are modest because the regenerators are large: typically 150 to 400 mmWC at the fan. Recuperative furnaces need more because of the recuperator and burner. Furnaces also carry separate fans for electrode and throat cooling, dilution air and forehearths, which are not the FD fan.

Air at the FD fan

Air temperature at the fanAmbient, 25 to 45°C
Air after heat recovery1,100 to 1,300°C after regenerators; 600 to 800°C after a recuperator
DustBatch house dust around the furnace; filtered intake needed
Pressure at the fan outletTypically 150 to 400 mmWC
Duty patternContinuous for the whole campaign, with reversals every 20 to 30 minutes
Density at the design temperatureAbout 1.13 kg/m³ at 40°C, 94% of standard air. Pressure developed and power drawn scale with density, so the fan is selected at this condition and the motor is checked at the coldest operating or start-up condition.

FD Fan selection for glass melting furnaces

Blade formBackward curved, for efficiency on continuous duty
Material of constructionMild steel
Drive and arrangementDirect coupled, arrangement 4 or 8, with a full standby fan
Bearings and coolingStandard bearings with condition monitoring
Flow controlVariable speed drive on combustion air flow, ratioed to fuel
Also specifiedInlet filter, silencer, automatic standby changeover and emergency power

What this FD fan has to cope with

Reliability over a long campaign

The combustion air fan must run for years without a planned stop. A bearing failure that stops firing chills the glass and can crack the refractory. Two fans with automatic changeover, condition monitoring on both and a supply from an emergency generator are the normal arrangement, with the standby fan run regularly so that it is known to be ready.

Air flow during reversal

During reversal the air flow briefly stops or switches sides as the valve moves. A fan working against a closed valve can surge, and the pressure spike stresses ducts and expansion joints. A fan with a stable curve close to shut-off, a short slowdown of the drive during reversal, or a relief path keeps the fan steady while the valves move.

Batch dust in the intake

Fine batch dust from the batch house and doghouse blocks inlet filters and is carried into the regenerators, where it adds to the checker plugging that already limits furnace life. Taking air from a clean location, through a filter with a pressure gauge across it, protects both the fan and the checkers at little cost.

Energy and control

The combustion air fan runs every hour of a long campaign. Controlling it by speed rather than by a throttle saves steadily, especially when pull rate is reduced. More important for cost is accurate air-fuel ratio: excess air through regenerators wastes fuel and raises NOx, so the fan must deliver precise, measured flow.

ID fan and FD fan in glass melting furnaces

ID fanFD fan
PositionAfter the filter, before the chimneyBefore the regenerators or recuperator
What it handlesWaste gas with sulphate dust and acid gasesAmbient filtered air
Temperature at the fan180 to 400°CAmbient
Main design concernAcid dew point, deposits and reliabilityReliability and accurate air flow
ControlFurnace crown pressureAir flow ratioed to fuel

See also the Induced Draft (ID) Fan for glass melting furnaces.

Questions buyers ask

Does an oxy-fuel glass furnace need an FD fan?

No. An oxy-fuel furnace burns its fuel with oxygen supplied from a VPSA unit or liquid storage, so there is no combustion air fan. It still needs small fans for electrode and throat cooling, quench or dilution air and the forehearths, and an ID fan or ejector to remove the waste gas from the melter.

What pressure does a glass furnace combustion air fan need?

For a regenerative furnace, typically 150 to 400 mmWC, because the checker chambers are large with low velocity. Recuperative furnaces need more, to overcome the recuperator and burners. The figure is set from the regenerator or recuperator resistance at maximum pull and the burner requirement.

Why do glass furnaces have a standby combustion air fan?

The furnace runs for 10 years or more without stopping, and losing combustion air means losing firing. A second fan with automatic changeover lets one fan be serviced while the furnace keeps running, and protects the glass and refractory if the duty fan fails. Both fans are normally on the emergency power supply.

Information needed to quote an FD fan for glass melting furnaces

  1. Duty point. Combustion air quantity in m³/h or kg/h and the static pressure at the fan outlet, with the margins you want.
  2. Air condition. Site ambient temperature range and altitude, and whether the fan takes ambient air or air already heated.
  3. System. Boiler or furnace capacity and fuel, resistance of the air heater, windbox, grate or burner, and the existing fan curve or nameplate if this is a replacement.
  4. Mechanical. Drive arrangement, flow control (damper, inlet vanes or variable speed drive), noise limit, rotation and discharge orientation.
  5. Heat recovery type. Regenerative or recuperative, and air side pressure drop at maximum pull.
  6. Standby and power. Whether a standby fan and emergency power supply are required.

Built and tested in Chennai

Adroit Fantech Engineers has designed and manufactured industrial fans at Ayanambakkam, Chennai since 2004. Each impeller, casing and shaft is built for the gas and temperature it will see, performance tested as per IS 4894 or BS 848 Part I, and balanced to grade G 6.3 or G 2.5 as per ISO 21940-11, with the records supplied with the fan. We also replace rotors and retrofit existing fans of any make.

FD Fan for related applications

Industries

Services on this fan

FD Fan for glass melting furnaces: send us your duty point

Flow, pressure, air temperature and the fuel are enough to start a selection.

Get a quote