Forced Draft (FD) Fan · designed and built in Chennai

Forced Draft (FD) Fan for Clay Roofing Tile Kilns

The FD fan on a clay roofing tile kiln is the combustion air fan, supplying the side burners of a tunnel kiln or the burners of a roller kiln. Tiles stand in tall cassettes, so the burners rely on air momentum to drive heat into the middle of the setting, and the fan must deliver that momentum evenly to every burner position.

Send your duty pointCall +91 91766 67102
Ambient, 25 to 45°CAir temperature at the fan
1.13 kg/m³Air density at 40°C
Backward curvedBlade form

How clay roofing tile kilns work

Clay roofing tiles, from traditional Mangalore pattern tiles to modern interlocking and ridge tiles, are fired at about 950 to 1,100°C. Traditional plants use intermittent downdraught or updraught kilns fired with wood, coal or biomass, drawing on a chimney. Modern plants fire tiles standing in H-cassettes or on refractory setters in tunnel kilns, and fast roller kilns are used for some profiles. Fuel is natural gas, LPG, producer gas or fuel oil. Roofing tile clays often carry fluorine, sulphur and chlorine, released as HF, SO₂ and HCl in the preheat zone between about 500 and 900°C, so newer kilns pass the flue gas through a dry lime absorber. The ID fan draws gas out of the preheat end and through any absorber; the FD fan supplies combustion air.

Where the FD fan sits

  1. Inlet filter
  2. FD fan
  3. Air main
  4. Burner valves
  5. Side or roof burners
  6. Kiln

The fan sits beside the firing zone and feeds an air main serving burners along both side walls, or in the roof on some kilns. High velocity burners need about 300 to 500 mmWC at the burner, so the fan typically delivers 400 to 700 mmWC. On traditional downdraught kilns firing wood or coal there is usually no FD fan; air enters by natural draft through the fire boxes, and a small blower is added only where burners or underfiring are fitted.

Air at the FD fan

Air temperature at the fanAmbient, 25 to 45°C
DustClay and lime dust around tile plants; filtered intake needed
Pressure at the fan outletTypically 400 to 700 mmWC
TurndownModerate; push rate changes with product and demand
Recovered airSome kilns use warm cooling air at 100 to 200°C for combustion
Density at the design temperatureAbout 1.13 kg/m³ at 40°C, 94% of standard air. Pressure developed and power drawn scale with density, so the fan is selected at this condition and the motor is checked at the coldest operating or start-up condition.

FD Fan selection for clay roofing tile kilns

Blade formBackward curved, high pressure
Material of constructionMild steel; heat-resisting impeller for recovered warm air
Drive and arrangementDirect coupled, two-pole speed
Bearings and coolingStandard bearings
Flow controlVariable speed drive on air main pressure
Also specifiedInlet filter, silencer and low pressure interlock to the burner system

What this FD fan has to cope with

Uneven firing across cassettes

Tiles at the centre of a cassette stack fire cooler than those at the outside if the burner jets are weak. When the air main pressure is low, the outer tiles over-fire while inner ones stay porous. Selecting the fan for the burners' full rated pressure, with margin for the main, keeps jet momentum high.

Dusty intake air

Tile plants handle dry clay, glaze, engobe and limestone granules for the absorber, and the air around the kiln carries fine abrasive dust. Unfiltered, it wears burner nozzles and ratio valves and builds up on the fan impeller, upsetting balance. A filtered intake drawing from a clean area, with a pressure gauge across the filter, avoids both problems at low cost.

Burner air loss in power dips

A short dip in the supply slows the fan, and the burners lose air before the flame safeguard reacts, giving smoky, rich combustion and soot on the tiles. In rural tile clusters such dips are common. A variable speed drive with ride-through capability, correctly set low air pressure interlocks and a fan with some inertia handle this without nuisance trips.

Energy and control

The combustion air fan runs with the kiln around the clock. Using a variable speed drive on air main pressure instead of a throttled damper reduces power when the kiln push rate is lowered for slower-selling products. Keeping the air-fuel ratio correct at every burner, which depends on stable main pressure, has a larger effect on fuel cost than the fan's own power.

ID fan and FD fan in clay roofing tile kilns

ID fanFD fan
PositionKiln entrance, after any lime absorberBeside the firing zone, feeding the burners
What it handlesFlue gas with HF, SO₂ and moistureAmbient filtered air
Temperature at the fan150 to 250°CAmbient
Main design concernAcid corrosion and absorber resistanceEven burner jet momentum
ControlPreheat zone pressureAir main pressure

See also the Induced Draft (ID) Fan for clay roofing tile kilns.

Questions buyers ask

Does a tile kiln need a combustion air fan?

A modern gas or oil fired tunnel or roller kiln does: the FD fan supplies air to every burner. Traditional wood or coal fired downdraught kilns usually do not, as air enters naturally through the fire boxes. A blower is added there only if burners are installed.

What pressure does a roofing tile kiln burner fan need?

High velocity burners on tile kilns usually need around 300 to 500 mmWC at the burner. With the air main and valve losses, the fan delivers about 400 to 700 mmWC. The burner manufacturer's data at full firing sets the final figure, and a margin is kept for future burners.

Why are high velocity burners used on tile kilns?

Tiles stand close together in cassettes, and hot gas must be driven into the setting to fire the middle tiles evenly. High velocity burner jets stir the kiln atmosphere and drive heat through the cassettes. They depend on the combustion air fan to supply full pressure.

Information needed to quote an FD fan for clay roofing tile kilns

  1. Duty point. Combustion air quantity in m³/h or kg/h and the static pressure at the fan outlet, with the margins you want.
  2. Air condition. Site ambient temperature range and altitude, and whether the fan takes ambient air or air already heated.
  3. System. Boiler or furnace capacity and fuel, resistance of the air heater, windbox, grate or burner, and the existing fan curve or nameplate if this is a replacement.
  4. Mechanical. Drive arrangement, flow control (damper, inlet vanes or variable speed drive), noise limit, rotation and discharge orientation.
  5. Burner arrangement. Number, position and type of burners and their air pressure at full firing.
  6. Intake location. Where the fan will draw air from and the dust conditions there.

Built and tested in Chennai

Adroit Fantech Engineers has designed and manufactured industrial fans at Ayanambakkam, Chennai since 2004. Each impeller, casing and shaft is built for the gas and temperature it will see, performance tested as per IS 4894 or BS 848 Part I, and balanced to grade G 6.3 or G 2.5 as per ISO 21940-11, with the records supplied with the fan. We also replace rotors and retrofit existing fans of any make.

FD Fan for related applications

Industries

Services on this fan

FD Fan for clay roofing tile kilns: send us your duty point

Flow, pressure, air temperature and the fuel are enough to start a selection.

Get a quote