13, Galaxy Road, Ponniamman Nagar, Ayanambakkam, Chennai 600 095 +91 91766 67102  |  +91 91766 67103  |  marketing@adroitfantech.com
Home › Applications › FD Fan › Glass Annealing Lehrs

Forced Draft (FD) Fan · designed and built in Chennai

Forced Draft (FD) Fan for Glass Annealing Lehrs

On a glass annealing lehr the FD fan is the cooling air supply fan, together with the combustion air blower on gas-fired lehrs. It pushes ambient air into the controlled and final cooling zones at a rate that sets the cooling curve, so even, adjustable air delivery across the belt decides the design.

Send your duty pointCall +91 91766 67102
Ambient, 25 to 45°CAir temperature at the fan
1.13 kg/m³Air density at 40°C
Backward curvedBlade form

How glass annealing lehrs work

An annealing lehr is a long tunnel with a mesh belt or rollers that takes formed glass from the forming machine and removes its stresses by controlled cooling. Containers and tableware enter at about 500 to 600°C, are reheated or held just above the annealing point, around 540 to 560°C for soda-lime glass, then cooled slowly through the strain range and finally quickly with air. Heating is by gas burners, firing directly into the tunnel or into a muffle, or by electric elements. Inside, recirculation fans drive hot air across the ware in each zone. Ambient air is blown into the cooling zones, and an exhaust fan removes the hot air and combustion products through a stack. Hot end coating and pharmaceutical dealkalisation treatments add HCl or sulphur compounds to the lehr atmosphere.

Where the FD fan sits

  1. Inlet filter
  2. FD (cooling air) fan
  3. Supply ducts
  4. Zone dampers
  5. Cooling zone nozzles or plenums
  6. Lehr tunnel

The fan stands beside the lehr, usually near the cold end, and supplies ambient air through ducts and dampers to plenums or nozzles in the cooling zones. In indirect cooling zones the air passes through tubes or a muffle and does not touch the ware; in direct zones it is blown onto the ware. On gas-fired lehrs a small combustion air blower supplies the burners. Pressure is moderate, typically 100 to 300 mmWC.

Air at the FD fan

Air temperature at the fanAmbient, 25 to 45°C
DustCullet and batch dust in the forming area; filtered intake recommended
Pressure at the fan outletTypically 100 to 300 mmWC
Load patternContinuous, varying with job, ware weight and line speed
Density at the design temperatureAbout 1.13 kg/m³ at 40°C, 94% of standard air. Pressure developed and power drawn scale with density, so the fan is selected at this condition and the motor is checked at the coldest operating or start-up condition.

FD Fan selection for glass annealing lehrs

Blade formBackward curved, for even delivery at moderate pressure
Material of constructionMild steel
Drive and arrangementDirect coupled or belt driven
Bearings and coolingStandard bearings
Flow controlVariable speed drive on cooling zone temperature, with zone dampers
Also specifiedInlet filter and silencer

What this FD fan has to cope with

Wrong cooling rate

Cooling too fast through the strain range leaves stress in the ware; too slowly wastes lehr length and limits line speed. A fixed-speed fan with dampers cannot hold the curve as ware weight changes. Variable speed control on zone temperature lets the cooling rate follow each job.

Uneven air across the belt

If cooling air reaches one side of the belt more than the other, ware on that side cools faster and carries more stress. Balanced plenum design and a fan with stable pressure keep delivery even across the width, which matters most on wide lehrs carrying several rows of containers.

Dust blown onto ware

Unfiltered air drawn from the forming hall carries cullet fines, swabbing compound residues and oil mist. Blown directly onto hot containers or tableware in the direct cooling zones, it marks the surface and can leave scratches that weaken the ware. A filtered intake taken from a clean location, with a pressure gauge across the filter, prevents this at little cost.

Energy and control

Cooling air demand varies with ware weight and line speed. A variable speed cooling air fan delivers only what the cooling curve needs, rather than running at full speed and throttling. Less excess cooling air also means less heat drawn back towards the heating zones, which reduces burner or element load.

ID fan and FD fan in glass annealing lehrs

ID fanFD fan
PositionExhaust hoods on heating and cooling zonesCold end, supplying cooling zone plenums
What it handlesHot air with combustion products and treatment fumesAmbient filtered air
Temperature at the fan150 to 300°CAmbient
Main design concernBalanced extraction and acid fumesEven, adjustable cooling air
ControlLehr pressure balanceCooling zone temperature

See also the Induced Draft (ID) Fan for glass annealing lehrs.

Questions buyers ask

Does a glass lehr have an FD fan?

A lehr has cooling air fans that force ambient air into the cooling zones, and gas-fired lehrs also have a combustion air blower for the burners. Together these are the forced draft side of the lehr. The exhaust fan on the other side is the lehr's ID fan.

How is the cooling rate controlled in an annealing lehr?

The cooling rate is set by the temperature profile in each cooling zone, controlled by the volume of cooling air and by the zone dampers. A variable speed cooling air fan, controlled on zone temperature, lets the cooling curve follow changes in ware weight and line speed without manual damper changes.

Why does uneven cooling air cause breakage?

Uneven cooling leaves residual stress in the ware, higher on the side that cooled faster. Stressed containers break on filling lines, in pasteurisers or in transport, and stressed tableware fails in dishwashers. Even cooling air delivery across the belt width, from a stable fan and balanced plenums, keeps the stress uniform and low.

Information needed to quote an FD fan for glass annealing lehrs

  1. Duty point. Combustion air quantity in m³/h or kg/h and the static pressure at the fan outlet, with the margins you want.
  2. Air condition. Site ambient temperature range and altitude, and whether the fan takes ambient air or air already heated.
  3. System. Boiler or furnace capacity and fuel, resistance of the air heater, windbox, grate or burner, and the existing fan curve or nameplate if this is a replacement.
  4. Mechanical. Drive arrangement, flow control (damper, inlet vanes or variable speed drive), noise limit, rotation and discharge orientation.
  5. Cooling zones. Number of direct and indirect cooling zones and the air flow to each.
  6. Ware range. Range of ware weight and line speed the lehr must handle.

Built and tested in Chennai

Adroit Fantech Engineers has designed and manufactured industrial fans at Ayanambakkam, Chennai since 2004. Each impeller, casing and shaft is built for the gas and temperature it will see, performance tested as per IS 4894 or BS 848 Part I, and balanced to grade G 6.3 or G 2.5 as per ISO 21940-11, with the records supplied with the fan. We also replace rotors and retrofit existing fans of any make.

FD Fan for related applications

Industries

Services on this fan

FD Fan for glass annealing lehrs: send us your duty point

Flow, pressure, air temperature and the fuel are enough to start a selection.

Get a quote