13, Galaxy Road, Ponniamman Nagar, Ayanambakkam, Chennai 600 095 +91 91766 67102  |  +91 91766 67103  |  marketing@adroitfantech.com
Home › Applications › FD Fan › Expanded Clay Aggregate Kilns

Forced Draft (FD) Fan · designed and built in Chennai

Forced Draft (FD) Fan for Expanded Clay Aggregate Kilns

The FD fan on an expanded clay aggregate kiln is the burner combustion air fan, usually the primary air fan of the kiln burner, with a separate fan supplying cooling air to the product cooler. Both handle ambient air. The design point is a stable flame across a wide firing range, since the bloating window is narrow.

Send your duty pointCall +91 91766 67102
Ambient, 20 to 45°CAir temperature at the fan
1.13 kg/m³Air density at 40°C
Backward curved for burner air on clean intakeBlade form

How expanded clay aggregate kilns work

Expanded clay aggregate is made by forming a bloating clay into pellets, drying and preheating them, then firing them in a rotary kiln at about 1,100 to 1,200°C, where gas released inside the softening clay expands each pellet into a light, cellular granule. Many plants use two drums: a drying and preheating drum followed by a shorter expansion drum, with the burner at the discharge end firing gas, oil, coal or pet coke. The kiln gas travels counter to the material and leaves the feed end at about 250 to 450°C with clay dust. It is cooled by dilution air or water spray, cleaned in cyclones and a bag filter and drawn out by the ID fan. The hot product is cooled in a rotary, grate or fluid bed cooler whose air partly returns to the kiln as secondary air.

Where the FD fan sits

  1. Air intake
  2. FD (primary air) fan
  3. Burner
  4. Expansion drum
  5. Cooler air fan
  6. Product cooler
  7. Secondary air to kiln

The primary air fan feeds the burner at the discharge end of the expansion drum; it carries coal or pet coke where a solid fuel is fired. The cooler air fan pushes ambient air through the hot product in the cooler, and much of that heated air is drawn into the kiln hood by the ID fan as secondary combustion air. Neither fan sees kiln gas or dust under normal conditions.

Air at the FD fan

Air temperature at the fanAmbient, 20 to 45°C
Secondary airHeated by the product in the cooler to several hundred °C, downstream of the cooler fan
DustClean ambient air; the cooler fan intake is often near dusty product handling and needs a filter
PressureModerate for the cooler fan; higher for a burner primary air fan with swirl and axial air
Fuel conveyingWith pulverised coal or pet coke, the primary air also conveys the fuel
Density at the design temperatureAbout 1.13 kg/m³ at 40°C, 94% of standard air. Pressure developed and power drawn scale with density, so the fan is selected at this condition and the motor is checked at the coldest operating or start-up condition.

FD Fan selection for expanded clay aggregate kilns

Blade formBackward curved for burner air on clean intake; radial or paddle wheel where the fan also conveys fuel
Material of constructionMild steel
Drive and arrangementDirect driven, with a variable speed drive
Bearings and coolingStandard bearings; no cooling needed
Flow controlVariable speed drive linked to the burner firing rate
Also specifiedIntake filter and silencer, and flow measurement for air to fuel ratio

What this FD fan has to cope with

Flame shape and bloating

The bloating window is narrow, so a flame that lengthens or wanders changes the expansion. Burner primary air must be steady and measured, and the fan selected so its operating point stays stable at low firing rates.

Dusty intake air

Cooler and burner fans often sit beside screening and conveying of the product. Unfiltered intake air carries dust into the fan and burner. An intake filter and a fan placed away from product handling avoid it.

Cooler air balance

If the cooler fan supplies more air than the kiln can take as secondary air, the excess must be vented. The cooler fan duty is matched to the kiln draft so that hot air is not wasted.

Energy and control

The burner and cooler fans run with the kiln, at loads set by the firing rate. Variable speed control lets the air follow the fuel accurately, which keeps excess air low and fuel use down. Using as much cooler air as possible as hot secondary air recovers heat from the product and reduces the fuel the burner must fire.

ID fan and FD fan in expanded clay aggregate kilns

ID fanFD fan
PositionAfter the bag filter, before the stackAt the burner and product cooler
What it handlesKiln gas with clay dust and SO₂Ambient combustion and cooling air
Temperature at the fan170 to 230°CAmbient
Main design concernClay dust erosion and kiln draftStable flame and air to fuel ratio
ControlKiln hood draftBurner firing rate

See also the Induced Draft (ID) Fan for expanded clay aggregate kilns.

Questions buyers ask

Which fan is the FD fan on a LECA kiln?

Usually the burner primary or combustion air fan. A separate cooler air fan supplies air to cool the product, and that heated air returns to the kiln as secondary air, so both fans together form the forced draft side of the kiln.

Does the cooler air fan handle hot air?

No. It takes ambient air and blows it through the hot product; the air heats up downstream of the fan. Only a fan that recirculates or exhausts cooler air sees hot, dusty air.

Why must the combustion air be steady on an expanded clay kiln?

Clay bloats only within a narrow temperature range. Unsteady air changes the flame length and the temperature profile, which moves the expansion zone and gives pellets of the wrong density.

Information needed to quote an FD fan for expanded clay aggregate kilns

  1. Duty point. Combustion air quantity in m³/h or kg/h and the static pressure at the fan outlet, with the margins you want.
  2. Air condition. Site ambient temperature range and altitude, and whether the fan takes ambient air or air already heated.
  3. System. Boiler or furnace capacity and fuel, resistance of the air heater, windbox, grate or burner, and the existing fan curve or nameplate if this is a replacement.
  4. Mechanical. Drive arrangement, flow control (damper, inlet vanes or variable speed drive), noise limit, rotation and discharge orientation.
  5. Burner type. Burner make and type, fuel, and required primary air pressure and share of total air.
  6. Cooler. Cooler type, cooling air flow and the share returned to the kiln.

Built and tested in Chennai

Adroit Fantech Engineers has designed and manufactured industrial fans at Ayanambakkam, Chennai since 2004. Each impeller, casing and shaft is built for the gas and temperature it will see, performance tested as per IS 4894 or BS 848 Part I, and balanced to grade G 6.3 or G 2.5 as per ISO 21940-11, with the records supplied with the fan. We also replace rotors and retrofit existing fans of any make.

FD Fan for related applications

Industries

Services on this fan

FD Fan for expanded clay aggregate kilns: send us your duty point

Flow, pressure, air temperature and the fuel are enough to start a selection.