13, Galaxy Road, Ponniamman Nagar, Ayanambakkam, Chennai 600 095 +91 91766 67102  |  +91 91766 67103  |  marketing@adroitfantech.com
Home › Applications › FD Fan › Mineral Flash Calciners

Forced Draft (FD) Fan · designed and built in Chennai

Forced Draft (FD) Fan for Mineral Flash Calciners

The FD fan on a mineral flash calciner is the burner combustion air fan. Most of the combustion air is drawn through the product coolers by the ID fan, preheated by the hot mineral, so the FD fan supplies only the burner primary air. It is small, but it sets flame shape and stability.

Send your duty pointCall +91 91766 67102
Ambient, 25 to 45°CAir temperature at the fan
1.13 kg/m³Air density at 40°C
High-pressure backward curved or radialBlade form

How mineral flash calciners work

Flash or gas suspension calciners treat fine minerals in a hot gas stream for a few seconds instead of hours in a kiln. Kaolin is converted to metakaolin at about 700 to 850°C, alumina hydrate to alumina at 1,000 to 1,100°C, and gypsum to plaster at 150 to 180°C, while magnesite and phosphates have their own windows. Feed passes up through cyclone preheaters, enters the calciner vessel where a burner fires oil or gas, and is separated in a hot cyclone. Product then cools in cyclone coolers or a fluid bed, which preheat the combustion air. The whole system typically runs under suction from a single ID fan after the ESP or bag filter, with a smaller FD fan supplying burner air.

Where the FD fan sits

  1. Inlet filter
  2. FD fan
  3. Burner primary air line
  4. Calciner burner

The fan sits near the calciner burner and delivers ambient air to it as primary air. The main combustion air enters through the product cooling cyclones under the suction of the ID fan, picking up heat from the mineral before it reaches the calciner. Some designs also use a separate fan to fluidise a fluid bed cooler. The primary air fan works against the burner and its piping, often 300 to 700 mmWC.

Air at the FD fan

Air temperature at the fanAmbient, 25 to 45°C
DustMineral dust in the plant; a filtered inlet is essential
Pressure at the fan outletTypically 300 to 700 mmWC, set by the burner
Share of total airPrimary air is usually a small fraction of the total combustion air
Density at the design temperatureAbout 1.13 kg/m³ at 40°C, 94% of standard air. Pressure developed and power drawn scale with density, so the fan is selected at this condition and the motor is checked at the coldest operating or start-up condition.

FD Fan selection for mineral flash calciners

Blade formHigh-pressure backward curved or radial, to suit the burner
Material of constructionMild steel
Drive and arrangementDirect coupled
Bearings and coolingStandard pedestal bearings
Flow controlVariable speed drive or damper, linked to burner firing
Also specifiedInlet filter, silencer and low-pressure interlock

What this FD fan has to cope with

Flame instability

The burner relies on primary air for flame shape and mixing. If the primary air pressure fluctuates, the flame can become unstable or impinge on the calciner wall, causing localised overheating. A fan with a steep pressure curve and good control at the burner keeps the flame steady.

Balance between primary and cooler air

Too much primary air reduces the air drawn through the coolers, so the product leaves hotter and less heat is recovered. The primary air flow is kept to the minimum the burner needs, and its control is coordinated with the ID fan draft so the total air and the share drawn through the coolers both stay on target.

Mineral dust at the fan inlet

Calcining plants handle fine powder, and an unfiltered inlet draws it into the fan and the burner, wearing both. A filtered inlet from a clean area is part of a good specification and costs little. Fine powder that reaches the burner can also block small air passages and upset the flame.

Energy and control

The primary air fan is small compared with the ID fan, but excess primary air costs fuel because it is cold air that bypasses the cooler heat recovery. Keeping primary air at the burner maker's minimum and using a variable speed drive saves both fan power and fuel. Checking the primary air setting after any burner change is a simple, low-cost step.

ID fan and FD fan in mineral flash calciners

ID fanFD fan
PositionAfter the ESP or bag filterAt the calciner burner
What it handlesSystem gas with fine mineral dustClean ambient air
Temperature at the fan150 to 250°CAmbient
Main design concernSteady draft through many cyclone stagesFlame stability
ControlCalciner pressure or temperatureBurner firing rate

See also the Induced Draft (ID) Fan for mineral flash calciners.

Questions buyers ask

Does a flash calciner have an FD fan?

It usually has a burner primary air fan, which acts as the FD fan. Most of the combustion air is drawn through the product coolers by the ID fan, where it is preheated. Some designs also have a fluidising air fan for a fluid bed cooler.

Why is the primary air fan pressure so high on a calciner burner?

Burner primary air is used to shape the flame and mix fuel with the hot secondary air. High-momentum burners need pressures of 300 to 700 mmWC or more. The fan is selected on the burner design to keep the flame stable throughout the firing range.

How is combustion air controlled in a flash calciner?

The ID fan draft controls the main air flow through the coolers and calciner, and the burner primary air fan supplies a controlled, small amount of air to the burner. Oxygen at the calciner outlet is used to trim the overall air-fuel ratio. The two fans are tuned together.

Information needed to quote an FD fan for mineral flash calciners

  1. Duty point. Combustion air quantity in m³/h or kg/h and the static pressure at the fan outlet, with the margins you want.
  2. Air condition. Site ambient temperature range and altitude, and whether the fan takes ambient air or air already heated.
  3. System. Boiler or furnace capacity and fuel, resistance of the air heater, windbox, grate or burner, and the existing fan curve or nameplate if this is a replacement.
  4. Mechanical. Drive arrangement, flow control (damper, inlet vanes or variable speed drive), noise limit, rotation and discharge orientation.
  5. Burner. Burner type, firing capacity and primary air pressure required.
  6. Cooler air. Whether cooler air is drawn by the ID fan or blown by a separate fan.

Built and tested in Chennai

Adroit Fantech Engineers has designed and manufactured industrial fans at Ayanambakkam, Chennai since 2004. Each impeller, casing and shaft is built for the gas and temperature it will see, performance tested as per IS 4894 or BS 848 Part I, and balanced to grade G 6.3 or G 2.5 as per ISO 21940-11, with the records supplied with the fan. We also replace rotors and retrofit existing fans of any make.

FD Fan for related applications

Industries

Services on this fan

FD Fan for mineral flash calciners: send us your duty point

Flow, pressure, air temperature and the fuel are enough to start a selection.

Get a quote