13, Galaxy Road, Ponniamman Nagar, Ayanambakkam, Chennai 600 095 +91 91766 67102  |  +91 91766 67103  |  marketing@adroitfantech.com
Home › Applications › FD Fan › Quartz Roasting Furnaces

Forced Draft (FD) Fan · designed and built in Chennai

Forced Draft (FD) Fan for Quartz Roasting Furnaces

The FD fan on a quartz roasting furnace is the combustion air fan for the burners. It pushes ambient air through the recuperator, where it is preheated, to the burners. It handles cold, clean air, but must hold steady burner pressure while the recuperator resistance and the firing rate change.

Send your duty pointCall +91 91766 67102
Ambient, 25 to 45°CAir temperature at the fan
1.13 kg/m³Air density at 40°C
Backward curvedBlade form

How quartz roasting furnaces work

Quartz lumps for high-purity silica, glass batch, ceramics and ferro-silicon are roasted at about 800 to 1,000°C and often quenched in water, so that the sudden temperature change cracks the quartz along grain boundaries and impurities. This makes crushing easier and exposes iron and mica inclusions for later removal. Rotary kilns, vertical shaft furnaces and batch car-bottom furnaces are used, fired on oil, gas or producer gas. Flue gas leaves the furnace at 400 to 700°C, often passes a recuperator that preheats combustion air, and then a cyclone or bag filter before the ID fan. Where the quench tank sits close to the furnace discharge, steam can enter the flue system. The FD fan supplies burner air.

Where the FD fan sits

  1. Inlet filter
  2. FD fan
  3. Recuperator
  4. Hot air main
  5. Burners

The fan sits at ground level before the recuperator and delivers ambient air into it. After the recuperator, preheated air at 250 to 450°C goes to the burners through an insulated main with a control valve at each burner or zone. The fan works against the recuperator, the hot air main, the valves and the burners, typically 300 to 600 mmWC depending on burner type.

Air at the FD fan

Air temperature at the fanAmbient, 25 to 45°C
Air after the recuperator250 to 450°C, downstream of the fan
DustQuartz dust around the crushing and loading area
Pressure at the fan outletTypically 300 to 600 mmWC
Density at the design temperatureAbout 1.13 kg/m³ at 40°C, 94% of standard air. Pressure developed and power drawn scale with density, so the fan is selected at this condition and the motor is checked at the coldest operating or start-up condition.

FD Fan selection for quartz roasting furnaces

Blade formBackward curved, on clean air
Material of constructionMild steel
Drive and arrangementDirect coupled
Bearings and coolingStandard pedestal bearings
Flow controlVariable speed drive on air main pressure
Also specifiedInlet filter, recuperator protection with a cold air bleed, and low-pressure interlock for burner safety

What this FD fan has to cope with

Recuperator overheating at low air flow

The air passing through the recuperator cools its tubes. If combustion air falls too low on reduced firing, the tubes overheat. A minimum air flow, maintained by the fan and released through a hot air bleed if necessary, protects the recuperator. The fan selection includes this minimum flow at the lowest firing rate.

Hot air volume at the burners

Preheated air is much less dense, so the burner valves and the fan pressure must account for the larger volume and pressure loss at 300 to 450°C. A fan selected only for cold air will run short at full firing. The pressure loss is therefore calculated at the actual hot air temperature in each section of the main.

Quartz dust at the inlet

Crushing and screening areas produce sharp quartz dust. Drawn into the fan, it wears the impeller and bearings. A filtered inlet away from crushers is a simple cure, and the filter pressure drop, with an allowance for loading, is included in the fan duty so the burners do not run short as it fills.

Energy and control

Firing on a quartz furnace changes with batch stage or feed rate. A variable speed drive on air main pressure avoids the losses of a throttled fan. The larger saving is in fuel: a recuperator that preheats combustion air to 300°C or more reduces fuel use considerably, and keeping the fan supply matched to the fuel limits excess air.

ID fan and FD fan in quartz roasting furnaces

ID fanFD fan
PositionAfter the recuperator and dust collectorBefore the recuperator
What it handlesHot flue gas with quartz finesClean ambient air
Temperature at the fan200 to 300°C, up to 400°C upsetAmbient
Main design concernHot-gas rating and overheat protectionBurner pressure with preheated air
ControlFurnace pressureAir main pressure and firing rate

See also the Induced Draft (ID) Fan for quartz roasting furnaces.

Questions buyers ask

Does the combustion air fan on a quartz roasting furnace handle hot air?

No. It is placed before the recuperator and handles ambient air. The air is heated downstream in the recuperator, so the fan itself runs cool and is built in mild steel. The fan must, however, provide the pressure needed to push the hot, expanded air through the main and the burners.

What pressure does a quartz roasting furnace combustion air fan need?

Typically 300 to 600 mmWC, depending on burner type, the recuperator and the hot air main. High-velocity burners need the upper end. The fan is selected on the burner maker's data plus all losses at hot air conditions downstream of the recuperator, including the recuperator itself.

How do I protect the recuperator if the combustion air fan trips?

Burners trip on low air pressure, and a hot gas bypass around the recuperator or a dilution damper upstream of it opens to protect the tubes. Some plants also keep a standby fan or allow natural air flow through the recuperator. The aim is to avoid the tubes running hot with no air to cool them.

Information needed to quote an FD fan for quartz roasting furnaces

  1. Duty point. Combustion air quantity in m³/h or kg/h and the static pressure at the fan outlet, with the margins you want.
  2. Air condition. Site ambient temperature range and altitude, and whether the fan takes ambient air or air already heated.
  3. System. Boiler or furnace capacity and fuel, resistance of the air heater, windbox, grate or burner, and the existing fan curve or nameplate if this is a replacement.
  4. Mechanical. Drive arrangement, flow control (damper, inlet vanes or variable speed drive), noise limit, rotation and discharge orientation.
  5. Burners. Number, type and firing capacity of the burners and the air pressure required at each.
  6. Recuperator. Air side pressure drop and the preheated air temperature.

Built and tested in Chennai

Adroit Fantech Engineers has designed and manufactured industrial fans at Ayanambakkam, Chennai since 2004. Each impeller, casing and shaft is built for the gas and temperature it will see, performance tested as per IS 4894 or BS 848 Part I, and balanced to grade G 6.3 or G 2.5 as per ISO 21940-11, with the records supplied with the fan. We also replace rotors and retrofit existing fans of any make.

FD Fan for related applications

Industries

Services on this fan

FD Fan for quartz roasting furnaces: send us your duty point

Flow, pressure, air temperature and the fuel are enough to start a selection.