13, Galaxy Road, Ponniamman Nagar, Ayanambakkam, Chennai 600 095 +91 91766 67102  |  +91 91766 67103  |  marketing@adroitfantech.com
Home › Applications › FD Fan › Silica Sand Dryers

Forced Draft (FD) Fan · designed and built in Chennai

Forced Draft (FD) Fan for Silica Sand Dryers

The FD fan on a silica sand dryer is the burner combustion air fan on a rotary dryer, or the fluidising air fan on a fluid bed dryer. In the fluid bed case it is a high-pressure fan that pushes the heated air through the distributor plate and sand bed, and bed pressure drop decides its design.

Send your duty pointCall +91 91766 67102
Ambient, 25 to 45°CAir temperature at the fan
1.13 kg/m³Air density at 40°C
Backward curved for burner airBlade form

How silica sand dryers work

Washed silica sand for glass, foundry, resin coating and construction chemicals leaves the washing plant with about 4 to 8% moisture and must be dried to below 0.1 to 0.5%. Two dryer types are common. A rotary dryer receives hot gas from a burner or hot gas generator at 500 to 700°C. A fluid bed dryer blows heated air up through a perforated plate so the sand bed fluidises, usually followed by a fluid bed or rotary cooler. Sand is nearly pure quartz, the most abrasive mineral that ordinary dryers handle, and the fines are a respirable crystalline silica hazard. The exhaust passes a cyclone and bag filter to the ID fan. The FD fan supplies burner or fluidising air.

Where the FD fan sits

  1. Inlet filter
  2. FD fan
  3. Burner or air heater
  4. Plenum below the plate
  5. Fluidised sand bed

On a rotary dryer the FD fan supplies the burner and works against 150 to 300 mmWC. On a fluid bed dryer the fan takes ambient air, pushes it through a direct-fired combustion chamber or air heater into the plenum, then through the distributor plate and the bed. The plate and a bed of dense sand together need typically 500 to 900 mmWC, so the fluidising fan is a high-pressure machine. It is placed before the heater so that it handles cold air.

Air at the FD fan

Air temperature at the fanAmbient, 25 to 45°C
Air after the heater250 to 500°C entering the plenum, downstream of the fan
DustSand dust in the plant; a filtered inlet is essential
Pressure at the fan outlet150 to 300 mmWC for a burner; 500 to 900 mmWC for fluidising air
Density at the design temperatureAbout 1.13 kg/m³ at 40°C, 94% of standard air. Pressure developed and power drawn scale with density, so the fan is selected at this condition and the motor is checked at the coldest operating or start-up condition.

FD Fan selection for silica sand dryers

Blade formBackward curved for burner air; high-pressure backward curved or radial for fluidising air
Material of constructionMild steel
Drive and arrangementDirect coupled
Bearings and coolingStandard pedestal bearings
Flow controlVariable speed drive on air flow or bed pressure
Also specifiedInlet filter and silencer; non-return damper so hot sand cannot flow back on trip

What this FD fan has to cope with

Defluidisation at reduced flow

A fluid bed needs a minimum air velocity to stay fluidised. If the fan cannot hold flow as bed depth or plate resistance rises, parts of the bed slump, sand dries unevenly and lumps form. A fan with a steep pressure curve and flow measurement on the fan inlet holds the air rate against these changes.

Sand back-flow on fan trip

If the fluidising fan stops, sand can fall through the plate into the plenum and hot gas can flow back towards the fan. A non-return damper at the fan outlet and a plate designed to prevent sifting protect the fan and simplify restart. The restart sequence starts the fan before the burner, so the bed is fluidised before hot air reaches it.

Silica dust drawn into the inlet

Sand plants are dusty, and a fan inlet near conveyors draws fine silica into the impeller, which wears it and the bearing seals. A filtered inlet from a clean area protects the fan and also keeps the distributor plate holes from wearing open, which would otherwise upset the air distribution across the bed over time.

Energy and control

The fluidising air fan is often the largest motor on a fluid bed sand dryer because of its high pressure. Operating it at the minimum flow that keeps the bed well fluidised, rather than at a fixed high setting, saves energy. A variable speed drive with flow measurement does this reliably. On rotary dryers the burner fan is small and savings come from lower excess air.

ID fan and FD fan in silica sand dryers

ID fanFD fan
PositionAfter the cyclone and bag filterBefore the burner or air heater
What it handlesExhaust with crystalline silica finesClean ambient air
Temperature at the fan90 to 120°CAmbient
Main design concernQuartz erosion and leak-tightnessBed pressure on fluid bed dryers
ControlDrum or hood suctionFluidising air flow or burner rate

See also the Induced Draft (ID) Fan for silica sand dryers.

Questions buyers ask

What is the FD fan on a fluid bed sand dryer?

It is the fluidising air fan. It pushes ambient air through the burner or air heater, the distributor plate and the sand bed. Because the plate and bed together need a high pressure, it is usually a high-pressure fan, unlike the low-pressure combustion air fan on a rotary dryer.

How much pressure does a fluidising air fan need for silica sand?

Typically 500 to 900 mmWC, made up of the distributor plate, the sand bed, which is roughly its weight per unit area, the heater and the ducts. The exact figure depends on bed depth and plate design, so the fan is sized from the dryer data with margin for bed variation.

Does the fluidising fan handle hot air?

Usually not. It is placed before the burner or air heater so that it handles cold ambient air, which keeps it smaller and simpler. Fans that recirculate hot air, used on some designs to save fuel, are a separate duty and are specified at the higher temperature.

Information needed to quote an FD fan for silica sand dryers

  1. Duty point. Combustion air quantity in m³/h or kg/h and the static pressure at the fan outlet, with the margins you want.
  2. Air condition. Site ambient temperature range and altitude, and whether the fan takes ambient air or air already heated.
  3. System. Boiler or furnace capacity and fuel, resistance of the air heater, windbox, grate or burner, and the existing fan curve or nameplate if this is a replacement.
  4. Mechanical. Drive arrangement, flow control (damper, inlet vanes or variable speed drive), noise limit, rotation and discharge orientation.
  5. Dryer type. Rotary or fluid bed dryer, and for fluid beds the bed area, depth and plate pressure drop.
  6. Heating. Direct-fired burner or indirect air heater, and the air temperature required at the plenum.

Built and tested in Chennai

Adroit Fantech Engineers has designed and manufactured industrial fans at Ayanambakkam, Chennai since 2004. Each impeller, casing and shaft is built for the gas and temperature it will see, performance tested as per IS 4894 or BS 848 Part I, and balanced to grade G 6.3 or G 2.5 as per ISO 21940-11, with the records supplied with the fan. We also replace rotors and retrofit existing fans of any make.

FD Fan for related applications

Industries

Services on this fan

FD Fan for silica sand dryers: send us your duty point

Flow, pressure, air temperature and the fuel are enough to start a selection.