13, Galaxy Road, Ponniamman Nagar, Ayanambakkam, Chennai 600 095 +91 91766 67102  |  +91 91766 67103  |  marketing@adroitfantech.com
Home › Applications › FD Fan › E-waste Thermal Treatment Furnaces

Forced Draft (FD) Fan · designed and built in Chennai

Forced Draft (FD) Fan for E-waste Thermal Treatment Furnaces

The FD fan on an e-waste thermal treatment furnace is the combustion air fan. It supplies primary air to the kiln or pyrolysis chamber and combustion air to the afterburner burner and secondary air ports. It handles clean ambient air, but the afterburner's destruction of brominated organics depends on getting enough air at the right point.

Send your duty pointCall +91 91766 67102
Ambient, 25 to 45°CAir temperature at the fan
1.13 kg/m³Air density at 40°C
Backward curvedBlade form

How e-waste thermal treatment furnaces work

E-waste thermal treatment furnaces burn or pyrolyse shredded printed circuit boards, cables and electronic scrap to remove plastics and recover copper and precious metals. Feed is charged to a rotary kiln, a batch pyrolysis chamber or a small smelting furnace at 500 to 900°C. The plastics, mainly epoxy and ABS with brominated flame retardants, give off a gas rich in organics, HBr and HCl. A secondary combustion chamber at about 1,100°C destroys the organics, after which the gas must be cooled quickly, by quench or heat exchanger, to below about 200°C to limit dioxin and furan reformation. Dry lime and activated carbon injection with a bag filter, often followed by a wet scrubber, cleans the gas before the ID fan.

Where the FD fan sits

  1. Inlet filter
  2. FD fan
  3. Air header
  4. Kiln primary air
  5. Afterburner burner
  6. Secondary air ports

The fan sits near the kiln and feeds a header with branches to the kiln burner and primary air, the afterburner burner and the afterburner's secondary air nozzles. On pyrolysis units, primary air is restricted or zero and most of the air goes to the afterburner. Pressure needed is typically 200 to 400 mmWC for the burners and mixing nozzles.

Air at the FD fan

Air temperature at the fanAmbient, 25 to 45°C
DustClean, filtered air
Pressure at the fan outletTypically 200 to 400 mmWC
Air splitVaries between kiln and afterburner with the feed
Excess oxygenAfterburner usually held at several percent oxygen
Density at the design temperatureAbout 1.13 kg/m³ at 40°C, 94% of standard air. Pressure developed and power drawn scale with density, so the fan is selected at this condition and the motor is checked at the coldest operating or start-up condition.

FD Fan selection for e-waste thermal treatment furnaces

Blade formBackward curved, for steady pressure
Material of constructionMild steel, painted
Drive and arrangementDirect drive
Bearings and coolingStandard bearings
Flow controlVariable speed drive on header pressure, with branch control valves on oxygen and temperature
Also specifiedInlet filter and silencer, and air flow measurement on each branch

What this FD fan has to cope with

Incomplete destruction of brominated organics

If the afterburner is short of air during a plastic-rich batch, brominated organics and soot pass through unburnt into the quench and gas cleaning, raising dioxin risk and fouling the bag filter. The fan is sized for the peak organic load, with secondary air nozzles that give strong mixing at about 1,100°C, not merely for the average feed.

Over-airing the pyrolysis chamber

On pyrolysis designs, too much primary air turns pyrolysis into burning inside the chamber. The temperature rises, metals oxidise and are harder to recover, and the gas volume becomes hard to control. Branch valves and flow measurement hold primary air at the intended low level, while the bulk of the air goes to the afterburner.

Branch flow imbalance

Without flow measurement on each branch, operators open dampers by habit and the afterburner can end up with the wrong air while the kiln is over-aired. Flow measurement on each branch, and automatic control of afterburner air from the exit oxygen analyser, keep the split right as the feed composition changes from batch to batch.

Energy and control

The afterburner burns support fuel to stay hot, and every cubic metre of excess air must be heated to about 1,100°C. Speed control on the combustion air fan, with oxygen trim in the afterburner, keeps excess air down and saves support fuel, which is the main running cost of the thermal stage. Fan power is a small part of the total.

ID fan and FD fan in e-waste thermal treatment furnaces

ID fanFD fan
PositionAfter bag filter and scrubberAhead of kiln and afterburner
What it handlesCleaned gas with HBr and HCl tracesAmbient air
Temperature at the fan140 to 180°C dry, 55 to 75°C wetAmbient
Main design concernHalide corrosion and high system resistanceAfterburner air for organics destruction
ControlKiln pressureAfterburner oxygen and temperature

See also the Induced Draft (ID) Fan for e-waste thermal treatment furnaces.

Questions buyers ask

What does the combustion air fan do on an e-waste thermal treatment plant?

On an e-waste thermal treatment plant the combustion air fan supplies air to the kiln or pyrolysis chamber and to the afterburner, where organics released from burning circuit boards are destroyed. Correct air supply and mixing in the afterburner is essential to destroy brominated organics before the gas is quenched and cleaned.

Is pyrolysis of e-waste done without air?

Pyrolysis restricts or eliminates air in the primary chamber, so the plastics decompose into gas and char rather than burning, and the metals stay largely unoxidised. The pyrolysis gas is then burned in an afterburner with air from the combustion air fan, which therefore carries most of the air duty on such plants.

How much excess air does an e-waste afterburner need?

Afterburners are usually run with several percent oxygen in the exit gas, which means significant excess air over the theoretical requirement. The fan must supply this at peak organic load, when a plastic-rich batch releases volatiles quickly, and the control must trim it back during low load to avoid wasting support fuel.

Information needed to quote an FD fan for e-waste thermal treatment furnaces

  1. Duty point. Combustion air quantity in m³/h or kg/h and the static pressure at the fan outlet, with the margins you want.
  2. Air condition. Site ambient temperature range and altitude, and whether the fan takes ambient air or air already heated.
  3. System. Boiler or furnace capacity and fuel, resistance of the air heater, windbox, grate or burner, and the existing fan curve or nameplate if this is a replacement.
  4. Mechanical. Drive arrangement, flow control (damper, inlet vanes or variable speed drive), noise limit, rotation and discharge orientation.
  5. Process type. Kiln incineration or pyrolysis, and the air split between primary and afterburner.
  6. Burner data. Burner capacities and the air pressure needed at the burners and nozzles.

Built and tested in Chennai

Adroit Fantech Engineers has designed and manufactured industrial fans at Ayanambakkam, Chennai since 2004. Each impeller, casing and shaft is built for the gas and temperature it will see, performance tested as per IS 4894 or BS 848 Part I, and balanced to grade G 6.3 or G 2.5 as per ISO 21940-11, with the records supplied with the fan. We also replace rotors and retrofit existing fans of any make.

FD Fan for related applications

Industries

Services on this fan

FD Fan for e-waste thermal treatment furnaces: send us your duty point

Flow, pressure, air temperature and the fuel are enough to start a selection.