13, Galaxy Road, Ponniamman Nagar, Ayanambakkam, Chennai 600 095 +91 91766 67102  |  +91 91766 67103  |  marketing@adroitfantech.com
Home › Applications › FD Fan › Biomass Gasifier Close-Coupled Boilers

Forced Draft (FD) Fan · designed and built in Chennai

Forced Draft (FD) Fan for Biomass Gasifier Close-Coupled Boilers

The FD fan on a biomass gasifier fired boiler is the combustion air fan. It supplies secondary air to burn the producer gas in the combustion chamber, and on pressurised designs a separate blower supplies gasification air. Its job is accurate air at the burner, because producer gas is lean and burns cleanly only in a narrow air range.

Send your duty pointCall +91 91766 67102
Ambient, 25 to 45°CAir temperature at the fan
1.13 kg/m³Air density at 40°C
Backward curvedBlade form

How biomass gasifier close-Coupled boilers work

In a close-coupled gasifier boiler, biomass such as wood chips, briquettes or coconut shell is partly oxidised in an updraft or downdraft gasifier to make producer gas, which flows straight into a combustion chamber attached to the boiler and burns there with secondary air. Because the gas is burnt hot, the tar it carries is burnt too, and the ash stays mostly in the gasifier. The flue gas leaves the combustion chamber at 1,000 to 1,200°C, passes the boiler tubes and an economiser, and reaches a small cyclone or bag filter at 160 to 220°C. Gasification air is supplied by a small blower or drawn in by suction, combustion air by an FD fan, and an ID fan maintains suction through the whole train.

Where the FD fan sits

  1. Inlet screen
  2. FD (combustion air) fan
  3. Air preheater (if fitted)
  4. Air control damper
  5. Gas burner or nozzles
  6. Combustion chamber

The fan sits near the combustion chamber and delivers ambient air to the burner or air nozzles around the producer gas inlet, sometimes through a small air preheater in the flue. Its pressure is modest, typically 100 to 250 mmWC, covering the ducts, control damper and burner. On pressurised gasifiers, a separate gasification air blower feeds the gasifier grate at a controlled rate.

Air at the FD fan

Air temperature at the fanAmbient, 25 to 45°C
Air after the preheaterUp to 150 to 250°C where a preheater is fitted
Pressure at the fan outletTypically 100 to 250 mmWC
DustClean air; screened against biomass dust
TurndownGas flow follows steam demand; low flows must stay stable
Density at the design temperatureAbout 1.13 kg/m³ at 40°C, 94% of standard air. Pressure developed and power drawn scale with density, so the fan is selected at this condition and the motor is checked at the coldest operating or start-up condition.

FD Fan selection for biomass gasifier close-Coupled boilers

Blade formBackward curved, small direct-driven unit
Material of constructionMild steel throughout
Drive and arrangementDirect mounted on the motor shaft, arrangement 4
Bearings and coolingMotor bearings only; no cooling
Flow controlVariable speed drive ratio-linked to gas flow or oxygen
Also specifiedInlet screen and a non-return flap to stop hot gas back-flow

What this FD fan has to cope with

Air-gas ratio drift

Producer gas from wood is lean, typically around 1,000 to 1,300 kcal/Nm³, and its quality moves with fuel moisture and bed condition. Too little air leaves tar and CO in the flue gas, and too much cools the flame below the point where tar burns. Speed control linked to flue gas oxygen holds the ratio as gas quality changes.

Back-flow of hot gas

When the combustion air fan stops while the combustion chamber is hot, producer gas and hot flue gas can flow back into the air duct and reach the fan. This can scorch the duct lining and create a flammable pocket. A non-return damper at the fan outlet and an interlock that closes the gas line valve on fan failure protect the fan and the duct.

Oversized fans at low load

Many gasifier boilers are supplied with combustion air fans selected with generous margins, then throttled hard by a damper for most of their life. At the low flows these plants often run at, a heavily throttled fan gives poor resolution and unstable air. A correctly sized fan or a speed drive gives finer control and better burnout.

Energy and control

The combustion air fan is small, but its control decides fuel efficiency. A variable speed drive with oxygen trim reduces excess air, which cuts both the stack loss and the ID fan power. On plants with a combustion air preheater, the added pressure drop is small and the fuel saving outweighs the extra fan power several times over.

ID fan and FD fan in biomass gasifier close-Coupled boilers

ID fanFD fan
PositionAfter the economiser and cyclone, before the chimneyAt the combustion chamber, feeding the gas burner
What it handlesLow-dust flue gas with some sootClean ambient air
Temperature at the fan170 to 220°CAmbient
Main design concernSteady suction through the gasifier and boilerAccurate air-gas ratio
ControlCombustion chamber suctionGas flow and oxygen

See also the Induced Draft (ID) Fan for biomass gasifier close-Coupled boilers.

Questions buyers ask

What is the FD fan on a gasifier boiler for?

On a gasifier fired boiler the FD fan supplies the combustion air that burns the producer gas in the combustion chamber. It does not handle the gas itself. In a pressurised gasifier, a separate blower supplies the air used for gasification, while in a suction gasifier that air is drawn in by the ID fan through the fuel bed.

How much air does producer gas need to burn?

Roughly 1 to 1.3 Nm³ of air per Nm³ of wood producer gas, plus excess air of 10 to 30% to complete combustion of tar and soot. The exact figure depends on the gas composition, which varies with fuel moisture, so it is best set by oxygen measurement in the flue rather than a fixed ratio.

Can the combustion air fan and gasifier blower be combined?

In some small designs one fan feeds both the gasifier and the burner through separate dampers. Separate fans give independent control of gasification rate and combustion air, which improves gas quality, tar burnout and turndown. On anything above a small packaged unit, two fans are usually the better arrangement.

Information needed to quote an FD fan for biomass gasifier close-Coupled boilers

  1. Duty point. Combustion air quantity in m³/h or kg/h and the static pressure at the fan outlet, with the margins you want.
  2. Air condition. Site ambient temperature range and altitude, and whether the fan takes ambient air or air already heated.
  3. System. Boiler or furnace capacity and fuel, resistance of the air heater, windbox, grate or burner, and the existing fan curve or nameplate if this is a replacement.
  4. Mechanical. Drive arrangement, flow control (damper, inlet vanes or variable speed drive), noise limit, rotation and discharge orientation.
  5. Producer gas data. Gas flow, typical composition or calorific value, and burner type.
  6. Gasification air. Whether gasification air comes from this fan, a separate blower, or ID fan suction.

Built and tested in Chennai

Adroit Fantech Engineers has designed and manufactured industrial fans at Ayanambakkam, Chennai since 2004. Each impeller, casing and shaft is built for the gas and temperature it will see, performance tested as per IS 4894 or BS 848 Part I, and balanced to grade G 6.3 or G 2.5 as per ISO 21940-11, with the records supplied with the fan. We also replace rotors and retrofit existing fans of any make.

FD Fan for related applications

Industries

Services on this fan

FD Fan for biomass gasifier close-Coupled boilers: send us your duty point

Flow, pressure, air temperature and the fuel are enough to start a selection.

Get a quote