13, Galaxy Road, Ponniamman Nagar, Ayanambakkam, Chennai 600 095 +91 91766 67102  |  +91 91766 67103  |  marketing@adroitfantech.com
Home › Applications › FD Fan › Spent Coffee Grounds Fired Boilers

Forced Draft (FD) Fan · designed and built in Chennai

Forced Draft (FD) Fan for Spent Coffee Grounds Fired Boilers

The FD fan on a spent coffee grounds fired boiler supplies fluidising or undergrate air through the air heater. Wet grounds need hot air to dry and ignite, and a fluidised bed needs steady pressure. The fan handles clean ambient air; its design is about pressure for the bed and enough hot air for the moisture of the day.

Send your duty pointCall +91 91766 67102
Ambient, 20 to 40°CAir temperature at the fan
1.13 kg/m³Air density at 40°C
Backward curvedBlade form

How spent coffee grounds fired boilers work

Spent coffee grounds are the residue left after extraction in instant coffee plants, mainly in south India. They leave the extraction columns at 70 to 80% moisture and are pressed to 50 to 60% before firing. On a dry basis they carry 1 to 2% ash, 10 to 15% residual coffee oil and a high calorific value of about 5,000 to 5,500 kcal/kg, but as fired they give only about 1,800 to 2,500 kcal/kg. Grounds are often dried further with flue gas in a rotary or flash dryer, then fired in a fluidised bed or on a grate, sometimes blended with coffee husk or wood. The flue gas passes the boiler, economiser and air heater, sometimes the dryer, then a cyclone and bag filter before the ID fan.

Where the FD fan sits

  1. Inlet screen
  2. FD fan
  3. Air heater
  4. Air box and distributor
  5. Fluidised bed or grate

The FD fan sits near the air heater and pushes ambient air through it, heated to about 180 to 250°C, into the bed air box or grate plenum. On a bubbling bed the fan pressure is typically 700 to 1,000 mmWC; on a grate, 150 to 250 mmWC. Secondary air for the freeboard usually comes from a separate fan, since the oily grounds release volatiles quickly once dried.

Air at the FD fan

Air temperature at the fanAmbient, 20 to 40°C
Air after the air heater180 to 250°C, downstream of the fan
DustClean air; coffee dust near the grounds handling
Pressure at the fan outlet700 to 1,000 mmWC for a fluidised bed; 150 to 250 mmWC for a grate
Fuel moisture effectWetter grounds need more hot air for drying
Density at the design temperatureAbout 1.13 kg/m³ at 40°C, 94% of standard air. Pressure developed and power drawn scale with density, so the fan is selected at this condition and the motor is checked at the coldest operating or start-up condition.

FD Fan selection for spent coffee grounds fired boilers

Blade formBackward curved, with a stable rising curve for bed duty
Material of constructionMild steel
Drive and arrangementDirect coupled, arrangement 8
Bearings and coolingStandard bearings; no cooling needed
Flow controlVariable speed drive on air flow, with minimum fluidising interlock
Also specifiedInlet screen, inlet silencer for bed fans

What this FD fan has to cope with

Wet grounds slumping the bed

A surge of wet grounds cools the bed and can make it sticky. If fluidising air falls at the same time, the bed slumps. The fan must hold minimum fluidising flow at all times, with pressure margin for a heavier bed, and the feed controlled so wet fuel does not arrive faster than the bed can dry it.

Oily volatiles and secondary air

Coffee oil releases volatiles quickly once the grounds dry. Without enough freeboard air they burn late or leave as smoke. The FD fan primary air and the secondary air must be balanced so the bed temperature stays steady and volatiles burn above it. Too much primary air simply blows fines into the freeboard.

Air heater fouling

Oily fines in the flue gas can foul the gas side of the air heater, reducing hot air temperature and raising its resistance. The FD fan pressure includes the fouled air heater, and the hot air temperature is monitored to show when cleaning is due.

Energy and control

The FD fan on a fluidised bed is a high pressure fan running continuously. Holding bed height near design, using a variable speed drive instead of a damper, and drying the grounds further all reduce its power. Oxygen trim on secondary air reduces the wet gas volume at the ID fan.

ID fan and FD fan in spent coffee grounds fired boilers

ID fanFD fan
PositionAfter the bag filter, often after the grounds dryerBefore the air heater, feeding the bed
What it handlesCool, wet flue gas with oily finesAmbient air
Temperature at the fan90 to 120°C after a dryerAmbient, 20 to 40°C
Main design concernCondensation and sticky depositsFluidising pressure with wet fuel
ControlFurnace or dryer draftAir flow with minimum fluidising interlock

See also the Induced Draft (ID) Fan for spent coffee grounds fired boilers.

Questions buyers ask

Can spent coffee grounds be burnt in a fluidised bed boiler?

Yes, and it is a common choice, because the bed tolerates wet fuel. The forced draft fan supplies fluidising air at high pressure through the air heater, and must hold minimum fluidising flow even when wet grounds cool the bed. Blending with coffee husk or wood steadies the bed temperature.

What FD fan pressure is needed for a coffee grounds fluidised bed?

Typically 700 to 1,000 mmWC, covering the air heater, ducts, distributor and bed. A grate fired unit needs about 150 to 250 mmWC. We size the fan from the bed design and boiler data, with margin for a heavier bed when wet grounds arrive and for fouling of the air heater by oily fines.

Why does my coffee grounds boiler lose bed temperature?

Usually because the grounds arrive wetter than normal and cool the bed faster than it can recover. Steady fluidising air, hot air at design temperature and controlled feeding help. Better pressing or drying of the grounds is the lasting fix. Blending in coffee husk also helps.

Information needed to quote an FD fan for spent coffee grounds fired boilers

  1. Duty point. Combustion air quantity in m³/h or kg/h and the static pressure at the fan outlet, with the margins you want.
  2. Air condition. Site ambient temperature range and altitude, and whether the fan takes ambient air or air already heated.
  3. System. Boiler or furnace capacity and fuel, resistance of the air heater, windbox, grate or burner, and the existing fan curve or nameplate if this is a replacement.
  4. Mechanical. Drive arrangement, flow control (damper, inlet vanes or variable speed drive), noise limit, rotation and discharge orientation.
  5. Firing system. Fluidised bed or grate, with bed area and distributor pressure drop.
  6. Hot air. Required hot air temperature and the air heater air-side pressure drop.

Built and tested in Chennai

Adroit Fantech Engineers has designed and manufactured industrial fans at Ayanambakkam, Chennai since 2004. Each impeller, casing and shaft is built for the gas and temperature it will see, performance tested as per IS 4894 or BS 848 Part I, and balanced to grade G 6.3 or G 2.5 as per ISO 21940-11, with the records supplied with the fan. We also replace rotors and retrofit existing fans of any make.

FD Fan for related applications

Industries

Services on this fan

FD Fan for spent coffee grounds fired boilers: send us your duty point

Flow, pressure, air temperature and the fuel are enough to start a selection.

Get a quote