Forced Draft (FD) Fan for Poultry Litter Fired Boilers

The FD fan on a poultry litter fired boiler often draws its air from the fuel storage hall, so the hall stays under slight suction and its ammonia odour is burnt in the furnace. That means the fan handles air carrying ammonia, litter dust and moisture rather than clean ambient air, and its materials and inlet filtration follow from that.

Send your duty pointCall +91 91766 67102
Ambient to about 45°C, warmer when litter in the hall is compostingAir temperature at the fan
1.11 kg/m³Air density at 45°C
Backward curvedBlade form

How poultry litter fired boilers work

Poultry litter is the mix of droppings and bedding, usually rice husk, sawdust or wood shavings, removed from broiler sheds between flocks. It is fired in dedicated power and steam plants on a moving grate or a bubbling fluidised bed. As fired it carries 20 to 40% moisture, 10 to 25% ash and a calorific value of about 2,500 to 3,500 kcal/kg. It is far richer in nitrogen, chlorine, sulphur, phosphorus, potassium and calcium than wood or husk, and it smells of ammonia. The ash is a saleable fertiliser. The flue gas passes the superheater, economiser and air heater, then dry lime or sorbent injection and a bag filter to remove HCl, SO₂ and dust, before the ID fan.

Where the FD fan sits

  1. Fuel storage hall extract
  2. Inlet filter
  3. FD fan
  4. Air heater
  5. Undergrate plenum or air distributor
  6. Grate or fluidised bed

The FD fan takes air from ducts at the roof of the litter storage hall, through a coarse filter, and pushes it through the air heater to the grate or bed. Drawing the air from the hall keeps the building at negative pressure and burns the odour. On a grate the fan works against 150 to 250 mmWC; on a bubbling bed, 700 to 1,000 mmWC. A secondary air fan, often also drawing from the hall, feeds the overfire nozzles.

Air at the FD fan

Air temperature at the fanAmbient to about 45°C, warmer when litter in the hall is composting
Air after the air heater150 to 200°C, downstream of the fan
DustFine litter dust, feathers and bedding fragments
Humidity and gasesHumid air with ammonia from the stored litter
Pressure at the fan outlet150 to 250 mmWC for a grate; 700 to 1,000 mmWC for a fluidised bed
Density at the design temperatureAbout 1.11 kg/m³ at 45°C, 93% of standard air. Pressure developed and power drawn scale with density, so the fan is selected at this condition and the motor is checked at the coldest operating or start-up condition.

FD Fan selection for poultry litter fired boilers

Blade formBackward curved, with smooth blades that do not hold dust
Material of constructionMild steel with an epoxy or similar protective coating; no copper alloys in contact with the air
Drive and arrangementDirect coupled, arrangement 8
Bearings and coolingStandard bearings, sealed against dust
Flow controlVariable speed drive on air flow with oxygen trim
Also specifiedCoarse inlet filter with differential pressure alarm, access door and casing drain

What this FD fan has to cope with

Dust and feathers on the impeller

Air from the litter hall carries dust, feathers and bedding fragments that build up on the impeller and filter. Without a filter the wheel unbalances within weeks. A coarse filter sized for low velocity, with an alarm on its pressure drop, and an access door for cleaning the wheel keep the fan in balance.

Ammonia and humid air

Stored litter releases ammonia and moisture. Ammonia attacks copper and brass fittings, and humid air condenses in cold ducts. A coated steel fan without copper alloy parts, sealed bearings, and a drain at the low point of the casing handle the condition. Insulating the duct from the hall where it runs outdoors limits condensation in cooler months.

Hall suction and combustion demand

The fan must hold the hall at negative pressure and supply combustion air at the same time. When the boiler turns down, the hall extract falls too. A bypass or a separate hall extract fan to the furnace covers low load without upsetting the excess air.

Energy and control

Litter plants run steadily at base load, so the FD fan runs near one point. A variable speed drive with oxygen trim keeps excess air near design and avoids throttling losses. Because the fan also ventilates the fuel hall, minimum speed is set by the hall suction needed, and the selection must give good efficiency at that point as well as at full load.

ID fan and FD fan in poultry litter fired boilers

ID fanFD fan
PositionAfter the bag filterDrawing from the fuel hall, before the air heater
What it handlesFlue gas with HCl, SO₂ and hygroscopic ashHall air with ammonia and litter dust
Temperature at the fan150 to 180°CAmbient to about 45°C
Main design concernAcid corrosionDust build-up and ammonia
ControlFurnace draftAir flow, oxygen and hall suction

See also the Induced Draft (ID) Fan for poultry litter fired boilers.

Questions buyers ask

Why does a poultry litter boiler draw combustion air from the fuel store?

Stored litter releases ammonia and odour. Drawing the forced draft fan air from the storage hall keeps the building under suction so odour does not escape, and the ammonia is burnt in the furnace. It also removes dust that would otherwise settle in the hall.

What material is used for the FD fan on a litter fired boiler?

Coated mild steel is usual, with no copper or brass parts, since ammonia attacks copper alloys. The air drawn from the litter hall is humid and dusty, so the casing has a drain and an access door for cleaning, and the bearings are sealed against dust. Stainless steel is rarely needed.

Does the FD fan on a poultry litter boiler need a filter?

Yes. Air from the litter hall carries dust, feathers and bedding fragments. A coarse filter with a pressure drop alarm protects the impeller and the air heater from build-up. The filter's pressure drop at its dirty condition must be included in the FD fan pressure, or airflow falls as it loads.

Information needed to quote an FD fan for poultry litter fired boilers

  1. Duty point. Combustion air quantity in m³/h or kg/h and the static pressure at the fan outlet, with the margins you want.
  2. Air condition. Site ambient temperature range and altitude, and whether the fan takes ambient air or air already heated.
  3. System. Boiler or furnace capacity and fuel, resistance of the air heater, windbox, grate or burner, and the existing fan curve or nameplate if this is a replacement.
  4. Mechanical. Drive arrangement, flow control (damper, inlet vanes or variable speed drive), noise limit, rotation and discharge orientation.
  5. Air source. Whether combustion air is drawn from the fuel hall, and the hall volume and suction required.
  6. Firing system. Grate or fluidised bed, and the share of secondary air.

Built and tested in Chennai

Adroit Fantech Engineers has designed and manufactured industrial fans at Ayanambakkam, Chennai since 2004. Each impeller, casing and shaft is built for the gas and temperature it will see, performance tested as per IS 4894 or BS 848 Part I, and balanced to grade G 6.3 or G 2.5 as per ISO 21940-11, with the records supplied with the fan. We also replace rotors and retrofit existing fans of any make.

FD Fan for related applications

Industries

Services on this fan

FD Fan for poultry litter fired boilers: send us your duty point

Flow, pressure, air temperature and the fuel are enough to start a selection.

Get a quote