Induced Draft (ID) Fan for Biomass Gasifier Close-Coupled Boilers

The ID fan on a biomass gasifier fired boiler pulls gas from the combustion chamber through the boiler and economiser, and in many designs also draws the producer gas through the gasifier itself. Steady suction is essential, because it sets the gasification rate as well as the furnace draft.

Send your duty pointCall +91 91766 67102
170 to 220°C after the economiserGas temperature, normal
0.75 kg/m³Gas density at 200°C
Backward curvedBlade form

How biomass gasifier close-Coupled boilers work

In a close-coupled gasifier boiler, biomass such as wood chips, briquettes or coconut shell is partly oxidised in an updraft or downdraft gasifier to make producer gas, which flows straight into a combustion chamber attached to the boiler and burns there with secondary air. Because the gas is burnt hot, the tar it carries is burnt too, and the ash stays mostly in the gasifier. The flue gas leaves the combustion chamber at 1,000 to 1,200°C, passes the boiler tubes and an economiser, and reaches a small cyclone or bag filter at 160 to 220°C. Gasification air is supplied by a small blower or drawn in by suction, combustion air by an FD fan, and an ID fan maintains suction through the whole train.

Where the ID fan sits

  1. Gasifier
  2. Producer gas line
  3. Combustion chamber
  4. Boiler tubes
  5. Economiser
  6. Cyclone or bag filter
  7. ID fan
  8. Chimney

The fan sits at the end of the train after a small cyclone or bag filter. In suction-type systems it is the only fan pulling gas through the fuel bed of the gasifier, so its suction must cover the gasifier bed, the gas line, the burner, the boiler and the collector, often 150 to 250 mmWC. In pressurised designs, a gasification blower pushes air into the gasifier and the ID fan only handles the boiler side, at lower suction.

Gas at the ID fan

Gas temperature, normal170 to 220°C after the economiser
Maximum or upsetUp to 280°C if the economiser is bypassed or fouled with soot
Dust at the fanLow; fine char and soot, typically below 200 mg/Nm³ after a cyclone
Moisture and dew pointWater dew point 50 to 60°C with chipped wood
Corrosive speciesTar and soot if combustion is poor; low sulphur and chlorine with wood
Density at the design temperatureAbout 0.75 kg/m³ at 200°C, 63% of standard air. Pressure developed and power drawn scale with density, so the fan is selected at this condition and the motor is checked at the coldest operating or start-up condition.

ID Fan selection for biomass gasifier close-Coupled boilers

Blade formBackward curved, for efficiency on lightly loaded gas
Material of constructionMild steel casing and impeller; stainless shaft sleeve where tar is a concern
Drive and arrangementDirect coupled or belt driven on small units, arrangement 8 or 9
Bearings and coolingPedestal bearings with a cooling disc
Flow controlVariable speed drive on combustion chamber suction
Also specifiedAccess door for soot cleaning, casing drain, and a gas-tight shaft seal

What this ID fan has to cope with

Suction sets the gas rate

Where the ID fan pulls air through the gasifier, any change in fan speed changes the gasification rate and the producer gas quality as well as the furnace draft. A fan controlled only by a manually set damper makes the flame hunt as the fuel bed settles. A speed-controlled fan with a fast pressure loop on the combustion chamber gives steady gas production.

Tar and soot after poor combustion

If secondary air is short or the combustion chamber runs cold at low load, unburnt tar from the producer gas condenses as soot and sticky deposits in the economiser and on the fan blades. Smooth backward curved blades, an access door for cleaning, and correct combustion air control at low load keep deposits manageable and avoid unbalance.

Back-flow and gas safety

Producer gas is toxic and flammable. Loss of the ID fan while the gasifier is hot can push gas back through the feed and air inlets into the boiler house. Interlocks that stop the fuel feed and open a flare or vent on fan failure are part of the system design, and the fan motor is often given a dependable supply for this reason.

Energy and control

Gasifier boilers are usually small, 1 to 10 TPH, but the ID fan runs continuously, often against a damper set during commissioning. A variable speed drive on combustion chamber suction gives finer control of the gasification rate and saves power during low steam demand. Keeping the economiser clean holds the gas temperature, and therefore the gas volume at the fan, close to design.

ID fan and FD fan in biomass gasifier close-Coupled boilers

ID fanFD fan
PositionAfter the economiser and cyclone, before the chimneyAt the combustion chamber, feeding the gas burner
What it handlesLow-dust flue gas with some sootClean ambient air
Temperature at the fan170 to 220°CAmbient
Main design concernSteady suction through the gasifier and boilerAccurate air-gas ratio
ControlCombustion chamber suctionGas flow and oxygen

See also the Forced Draft (FD) Fan for biomass gasifier close-Coupled boilers.

Questions buyers ask

Does a biomass gasifier boiler need an ID fan?

Most do. In suction gasifiers the ID fan draws air through the fuel bed and moves the gas to the burner. In pressurised designs a blower feeds the gasifier and the ID fan handles the boiler side. Natural draft alone is rarely enough for the combined resistance of the gasifier bed, boiler, economiser and collector.

Why is there soot in my gasifier boiler ID fan?

Soot comes from producer gas tar that did not burn fully, usually because secondary air was short, the gas was too wet, or the combustion chamber ran cold at low load. Correcting air control, keeping the chamber refractory hot, and cleaning the economiser and fan at regular intervals prevent the build-up that leads to unbalance.

What happens if the ID fan trips on a gasifier boiler?

The gasifier keeps producing gas for some time after the fan stops, because the fuel bed is still hot. Without suction, producer gas can leak into the boiler house through feed doors and air inlets. Fuel feed must stop at once, and the gas should be vented or flared through a dedicated safety path controlled by interlocks.

Information needed to quote an ID fan for biomass gasifier close-Coupled boilers

  1. Duty point. Gas volume in m³/h or Am³/h at the fan inlet and the static pressure the fan must develop, with the margin you want on each.
  2. Gas condition. Normal and maximum gas temperature at the fan, dust loading after the collector, moisture and any acid gases such as SO₂ or HCl.
  3. System. Boiler or furnace capacity and fuel, collector type and its pressure drop, and the existing fan curve or nameplate if this is a replacement.
  4. Mechanical. Drive arrangement, flow control (damper, inlet vanes or variable speed drive), rotation and discharge orientation, and a layout drawing or site photograph.
  5. Gasifier type. Updraft or downdraft, suction or pressurised, and the gasifier bed pressure drop.
  6. Safety interlocks. How the plant handles a fan trip, and whether a flare or vent is fitted.

Built and tested in Chennai

Adroit Fantech Engineers has designed and manufactured industrial fans at Ayanambakkam, Chennai since 2004. Each impeller, casing and shaft is built for the gas and temperature it will see, performance tested as per IS 4894 or BS 848 Part I, and balanced to grade G 6.3 or G 2.5 as per ISO 21940-11, with the records supplied with the fan. We also replace rotors and retrofit existing fans of any make.

ID Fan for related applications

Industries

Services on this fan

ID Fan for biomass gasifier close-Coupled boilers: send us your duty point

Flow, pressure, gas temperature and the fuel are enough to start a selection.