The process
Zero liquid discharge distilleries concentrate spent wash and fire it with bagasse or coal as support fuel in a slop fired boiler. The ash is high in potash and sticky, the gas is corrosive, and the ID fan is built for deposit and attack that a plain bagasse boiler fan does not see.
The gas at the fan
Mixed biomass fuels give variable ash and moisture. The fan is sized for the worst fuel in the mix, with wear protection and deposit shedding as for bagasse.
Selection for this duty
| Construction | Absorptive annular design in mild steel; stainless steel where the gas is wet or corrosive |
| Density at the fan | At about 170°C the gas density is close to 0.80 kg/m³, 66% of standard air. Pressure developed and power drawn fall in the same ratio, so the selection is made at this density and the motor is checked at cold start. |
An absorptive silencer at the fan inlet, outlet or in the duct, cutting fan noise with minimum pressure loss. Client-stated blade types for the Fan Silencer in general: Silencer.
Industries
Other fans in distillery spent wash incineration boilers
Fan Silencer in other processes
Information needed to select or quote
- Gas volume and temperature. Actual flow at the inlet, normal and upset temperature, moisture.
- Dust or pollutant. Inlet loading, particle size distribution, whether it is abrasive, sticky, hygroscopic or combustible; for gases, the species and concentration.
- Required outlet. The emission limit or clean gas concentration the unit must meet.
- Site. Available space and height, material of construction preferences, and how the collected material is to be discharged.