Secondary Air Fan for Distillery Spent Wash Incineration Boilers

Supplies the secondary combustion air that completes burning above the grate or around the burner. In distillery spent wash incineration boilers the gas at the fan is biomass boiler flue gas, and that sets the blade form, the material and the drive.

The process

Zero liquid discharge distilleries concentrate spent wash and fire it with bagasse or coal as support fuel in a slop fired boiler. The ash is high in potash and sticky, the gas is corrosive, and the ID fan is built for deposit and attack that a plain bagasse boiler fan does not see.

The gas at the fan

Mixed biomass fuels give variable ash and moisture. The fan is sized for the worst fuel in the mix, with wear protection and deposit shedding as for bagasse.

Selection for this duty

Blade formRadial tipped with wear liners, or straight radial where the dust is coarse
Material of constructionMild steel with replaceable wear liners on the blades and the scroll at the cut-off, with a casing drain for the moisture
Drive and bearingsDirect coupled or belt driven with a shaft cooling disc and bearings outside the casing
Also specifiedHard facing or liners on the blade pressure face; casing drain at the lowest point
Density at the fanAt about 170°C the gas density is close to 0.80 kg/m³, 66% of standard air. Pressure developed and power drawn fall in the same ratio, so the selection is made at this density and the motor is checked at cold start.

Supplies the secondary combustion air that completes burning above the grate or around the burner. On bagasse and biomass boilers it also carries the over-fire air that controls the fuel bed. Client-stated blade types for the SA Fan in general: Backward curved and backward inclined.

Industries

Other fans in distillery spent wash incineration boilers

SA Fan in other processes

Information needed to select or quote

  1. Duty point. Volume flow and static pressure at the fan inlet, with the gas density and temperature or the conditions to derive it.
  2. Operating conditions. Site altitude, normal operating temperature and continuous or intermittent duty.
  3. Gas stream. Dust loading and particle size, corrosive species, moisture, upset temperature and any tendency of the material to deposit on the impeller.
  4. Mechanical. Rotation viewed from the drive end, discharge orientation and motor power.

Send us your duty point

Flow, pressure, gas condition and temperature are enough to start a selection.