Fans and Air Pollution Control for Waste Heat Recovery Boilers

A waste heat boiler sits on the exhaust of a kiln, furnace or engine and lowers the gas temperature before the dust collector and fan.

The process

A waste heat boiler sits on the exhaust of a kiln, furnace or engine and lowers the gas temperature before the dust collector and fan. The ID fan after the boiler handles the gas of the source process at reduced temperature, and dampers divert the gas around the boiler when it is out of service.

The gas

Exhaust from a kiln, furnace or engine after a waste heat boiler. Temperature and dust depend on the upstream process; the fan is selected at the hot condition with the dust load of the source.

Fans in this process

DutyWhat it does hereType usually selected
ID FanSits at the outlet of a boiler, kiln or furnace and draws the flue gas through the plant to the stack.Backward curved, backward inclined and radial tipped
Dust Collector FanThe fan behind a bag filter, cyclone or multiclone on a dust extraction system.Backward inclined and radial tipped
Bag Filter FanPulls the process gas through the filter bags and discharges the cleaned gas to the stack.Backward curved and radial tipped
Dilution Air BlowerInjects ambient air into a hot flue gas stream to bring it down to a temperature the downstream bag filter or fan can accept..Backward curved
Fan SilencerAn absorptive silencer at the fan inlet, outlet or in the duct, cutting fan noise with minimum pressure loss..Silencer

Air pollution control

Industries

Related processes

Send us your duty point

Flow, pressure, gas condition and temperature are enough to start a selection.