Induced Draft (ID) Fan for Rice Husk Dumping Grate Boilers

The ID fan on a rice husk dumping grate boiler must hold furnace draft through a cycle that a continuous grate does not have: ash builds up between dumps, then each dump releases a puff of ash and disturbs the furnace pressure. Fast, stable draft control through that cycle decides the fan and drive design.

Send your duty pointCall +91 91766 67102
160 to 190°C after the air heaterGas temperature, normal
0.79 kg/m³Gas density at 175°C
Backward curved with wear linersBlade form

How rice husk dumping grate boilers work

A dumping grate is a stationary grate whose sections are tilted at intervals, by hand lever or pneumatic cylinder, to drop accumulated ash into the hopper below. Rice husk dumping grate boilers are typically water tube or hybrid units of about 4 to 20 TPH. Husk is fed by pneumatic spreaders or chutes and burns partly on the grate, partly in suspension. Between dumps, every one to four hours depending on load, the ash layer grows and grate resistance rises. During a dump, air to that section is shut off and the furnace sees a brief surge of ash and a change in draft. The gas then passes the boiler bank, economiser, air heater and a multiclone with ESP or bag filter before the ID fan.

Where the ID fan sits

  1. Dumping grate furnace
  2. Boiler bank
  3. Economiser
  4. Air heater
  5. Multiclone
  6. ESP or bag filter
  7. ID fan
  8. Chimney

The fan follows the final collector and holds the furnace a few millimetres negative. Total suction at the fan inlet is typically 150 to 250 mmWC. When a grate section tilts, the ash bed breaks up and fine silica and char are lifted into the gas stream for a short time, and sometimes a flare of unburnt husk follows. The collectors take most of this surge, but the fan sees a brief rise in dust and temperature at every dump.

Gas at the ID fan

Gas temperature, normal160 to 190°C after the air heater
Maximum or upsetBrief rises of 20 to 40°C after each dump
Dust at the fanSilica ash, with short surges after dumps; 50 to 200 mg/Nm³ after a bag filter or ESP
Draft variationShort swings of several mmWC at each dump
Corrosive speciesLow; husk is low in sulphur
Density at the design temperatureAbout 0.79 kg/m³ at 175°C, 66% of standard air. Pressure developed and power drawn scale with density, so the fan is selected at this condition and the motor is checked at the coldest operating or start-up condition.

ID Fan selection for rice husk dumping grate boilers

Blade formBackward curved with wear liners, chosen for a stable pressure curve across the draft swings
Material of constructionMild steel casing; wear-resistant plate or lined impeller blades
Drive and arrangementDirect coupled, arrangement 8
Bearings and coolingPedestal bearings with cooling disc
Flow controlVariable speed drive on furnace draft, tuned for fast response, with damper for isolation
Also specifiedLiners at the scroll, access door, casing drain, temperature margin for post-dump peaks

What this ID fan has to cope with

Draft swings at each dump

With a slow damper control, the furnace goes positive for a few seconds at each dump and hot gas escapes at the doors. A variable speed drive with a correctly tuned draft loop, and a fan whose pressure curve is stable over the operating range, keeps the furnace negative.

Ash surge to the collector and fan

Dumping lifts fine ash and char that would otherwise stay on the grate, and a short flare can carry glowing particles forward. A bag filter with spark arrestors, or an ESP, takes most of it. Liners at the impeller leading edge and the scroll cut-off protect the fan from the share that passes during the surge.

Rising resistance between dumps

As ash builds on the grate between dumps, operators often raise air to keep the husk burning, so excess air and gas volume drift upward through the cycle. A fan sized on the average condition runs short of capacity just before each dump. We size it on the highest gas volume in the cycle, not the average.

Energy and control

Dumping grate husk boilers usually serve parboiling and rice mill loads that vary through the day. A variable speed drive on the ID fan saves energy at part load and does the extra job of holding draft through each dump. Dumping more often at high load keeps the grate resistance and excess air lower, which reduces gas volume and fan power together.

ID fan and FD fan in rice husk dumping grate boilers

ID fanFD fan
PositionAfter ESP or bag filterBefore the air heater and section dampers
What it handlesFlue gas with silica ash, surges at dumpsAmbient undergrate air
Temperature at the fan160 to 190°CAmbient, 25 to 45°C
Main design concernHolding draft through each dumpSteady pressure as sections close
ControlVFD on furnace draftVFD on plenum pressure

See also the Forced Draft (FD) Fan for rice husk dumping grate boilers.

Questions buyers ask

Why does furnace pressure go positive when we dump the grate?

Tilting a section disturbs the ash bed and changes the air flow through the grate, and unburnt husk can flare as it falls. If the ID fan control is slow, the furnace briefly loses draft. A variable speed drive with a fast, well-tuned draft loop, and a fan with a stable curve, keep the furnace negative through the dump.

What ID fan is used on a rice husk dumping grate boiler?

Typically a backward curved ID fan with wear liners placed after an ESP or bag filter, designed for about 160 to 190°C and short temperature peaks after each dump, with a variable speed drive on furnace draft. Where the boiler has only a multiclone, a radial tipped wheel with liners is the safer choice.

Does grate dumping increase ID fan wear?

Somewhat. Each dump lifts a short burst of silica ash and char into the gas stream. Most is caught by the collector, but over a year these bursts add measurably to erosion at the blade inlet edges and the scroll cut-off. Liners at those points and a check of blade thickness at each shutdown handle it.

Information needed to quote an ID fan for rice husk dumping grate boilers

  1. Duty point. Gas volume in m³/h or Am³/h at the fan inlet and the static pressure the fan must develop, with the margin you want on each.
  2. Gas condition. Normal and maximum gas temperature at the fan, dust loading after the collector, moisture and any acid gases such as SO₂ or HCl.
  3. System. Boiler or furnace capacity and fuel, collector type and its pressure drop, and the existing fan curve or nameplate if this is a replacement.
  4. Mechanical. Drive arrangement, flow control (damper, inlet vanes or variable speed drive), rotation and discharge orientation, and a layout drawing or site photograph.
  5. Dumping cycle. Dumping interval, method (manual or pneumatic) and number of grate sections.
  6. Draft behaviour. Furnace pressure trend through a dump, if recorded.

Built and tested in Chennai

Adroit Fantech Engineers has designed and manufactured industrial fans at Ayanambakkam, Chennai since 2004. Each impeller, casing and shaft is built for the gas and temperature it will see, performance tested as per IS 4894 or BS 848 Part I, and balanced to grade G 6.3 or G 2.5 as per ISO 21940-11, with the records supplied with the fan. We also replace rotors and retrofit existing fans of any make.