Induced Draft (ID) Fan for NPK Granulation Plant Dryers

An NPK granulation plant has several induced draft fans: the granulator scrubber fan, the dryer ID fan and the dedusting fan. The dryer ID fan is the largest. What decides its design is the plant's grade mix, because urea-based grades bring sticky, low-melting dust and ammonia-rich grades bring heavy scrubber loads.

Send your duty pointCall +91 91766 67102
80 to 100°C after the dryer cyclonesGas temperature, normal
0.96 kg/m³Gas density at 95°C
Radial tipped or open backward curved for the dryer and dedusting fansBlade form

How NPK granulation plant dryers work

In an NPK granulation plant, phosphoric acid, ammonia and sulphuric acid react in a pipe reactor or pre-neutraliser, and the slurry is sprayed with solid potash, urea and recycle onto a rolling bed in the ammoniator-granulator. The granules then pass a rotary dryer, screens, crushers and a cooler, with recycle ratios typically 3 to 6 times the product rate. The granulator off-gas carries free ammonia and steam and is scrubbed with phosphoric acid; the dryer exhaust carries dust, ammonia and fluorides and goes through cyclones to its own scrubber; a third dedusting system serves screens and elevators. Each system has its own exhaust fan. Dryer inlet gas is typically 250 to 400°C, reduced on urea-based grades.

Where the ID fan sits

  1. Pipe reactor and granulator
  2. Rotary dryer
  3. Dryer cyclones
  4. Dryer ID fan
  5. Venturi and tail gas scrubbers
  6. Common stack

The dryer ID fan usually sits between the cyclones and the venturi scrubber, in a dry but dusty duty. The granulator fan sits after the granulator scrubber, handling saturated gas with ammonia and acid mist, and is rubber-lined or FRP. The dedusting fan follows a cyclone or bag filter on the screen and crusher hoods. On many plants all three discharge into a tail gas scrubber and a common stack, so each fan's pressure includes its share of that final scrubber.

Gas at the ID fan

Gas temperature, normal80 to 100°C after the dryer cyclones
Maximum or upsetUp to 140°C when the dryer loses feed during a granulation upset
Dust at the fanNPK fines, several g/Nm³ after cyclones; sticky and low-melting on urea-based grades
Moisture and dew pointModerate on the dryer fan; saturated at about 60 to 75°C on the granulator scrubber fan
Corrosive speciesAmmonia, fluorides from phosphoric acid, chlorides from potash
Density at the design temperatureAbout 0.96 kg/m³ at 95°C, 80% of standard air. Pressure developed and power drawn scale with density, so the fan is selected at this condition and the motor is checked at the coldest operating or start-up condition.

ID Fan selection for NPK granulation plant dryers

Blade formRadial tipped or open backward curved for the dryer and dedusting fans; backward curved for the clean, wet granulator scrubber fan
Material of constructionSS 316 or lined mild steel for the dryer fan; rubber-lined mild steel or FRP for the granulator scrubber fan
Drive and arrangementBelt driven or direct coupled, arrangement 9 or 8
Bearings and coolingBearings outside the gas stream; shaft seal against ammonia and dust
Flow controlVariable speed drive on dryer suction; damper on the smaller fans
Also specifiedWash nozzles, casing drain and inspection doors on every fan

What this ID fan has to cope with

Sticky dust on urea-based grades

Grades containing urea form low-melting eutectics with ammonium salts and produce dust that smears onto hot blades. Lower drum inlet temperatures, efficient cyclones and a fan with wash nozzles keep the build-up under control. Grades with high urea content may need more frequent washing. The fan casing door is sized for manual cleaning.

Chloride and fluoride corrosion

Potash adds chlorides and phosphoric acid adds fluorides, and both concentrate in deposits on the fan. Chlorides pit SS 304, so SS 316 or a lined construction is the safer choice where deposits stay damp. The casing drain must also stay open, because a pool of chloride-rich condensate at the bottom of the scroll is where corrosion usually starts.

Granulator scrubber fan in wet gas

The granulator fan sees saturated gas with acid mist and occasional slurry carry-over. A mist eliminator before the fan, a lined or FRP casing and a drain at the lowest point protect it. Rubber-lined fans are kept below the lining's temperature limit, so a high gas temperature trip from the granulator protects the lining during upsets.

Fan balance across the system

When the three fans share a tail gas scrubber, a change in one alters the others. Each fan is selected on its own branch losses plus the shared scrubber at full plant load. Dampers in each branch let the operator rebalance when one section is offline, and the fan curves are checked for stable operation in that state too.

Energy and control

NPK plants change grades often, and the recycle ratio and evaporation load change with them. A variable speed drive on the dryer ID fan follows these swings more efficiently than a damper. Lowering the recycle ratio through better granulation control reduces the dryer gas volume and the power of every fan in the loop.

ID fan and FD fan in NPK granulation plant dryers

ID fanFD fan
PositionAfter the dryer cyclones, before the scrubbersAt the dryer furnace burner
What it handlesDryer exhaust with NPK fines, NH₃, chlorides and fluoridesClean ambient air
Temperature at the fan80 to 100°CAmbient
Main design concernSticky dust and corrosionBurner turndown across grades
ControlDryer suctionBurner firing rate

See also the Forced Draft (FD) Fan for NPK granulation plant dryers.

Questions buyers ask

How many fans does an NPK granulation plant need?

Typically at least three exhaust fans: one for the granulator scrubber, one for the dryer, and one for dedusting screens, crushers and elevators. The cooler has its own air system, and the dryer furnace has a combustion air fan. Some plants combine dryer and cooler gases into one fan. Each fan duty is set by its own collector, scrubber and branch losses.

What material is used for the NPK dryer exhaust fan?

SS 316 or lined mild steel, because the dust carries chlorides and fluorides and absorbs moisture. The granulator scrubber fan, which handles saturated gas, is usually rubber-lined or FRP. Mild steel is only suitable where the fan stays well above dew point at all times. Inspection of the casing bottom at each shutdown shows whether the chosen material is coping with the plant's grades.

Why does the NPK dryer fan build up more on some grades?

Urea-containing grades form low-melting compounds that become sticky at dryer temperatures. The dust then smears onto the blades. Grade-specific drum temperatures and casing wash nozzles help control this. Plants making high-urea grades often schedule a fan wash at each grade change. A record of vibration against grade helps identify the worst grades.

Information needed to quote an ID fan for NPK granulation plant dryers

  1. Duty point. Gas volume in m³/h or Am³/h at the fan inlet and the static pressure the fan must develop, with the margin you want on each.
  2. Gas condition. Normal and maximum gas temperature at the fan, dust loading after the collector, moisture and any acid gases such as SO₂ or HCl.
  3. System. Boiler or furnace capacity and fuel, collector type and its pressure drop, and the existing fan curve or nameplate if this is a replacement.
  4. Mechanical. Drive arrangement, flow control (damper, inlet vanes or variable speed drive), rotation and discharge orientation, and a layout drawing or site photograph.
  5. Grade list. All grades produced, including urea-based grades, with dryer inlet and outlet temperatures.
  6. Scrubbing system. Scrubber layout for granulator, dryer and dedusting gases and whether they share a tail gas scrubber.

Built and tested in Chennai

Adroit Fantech Engineers has designed and manufactured industrial fans at Ayanambakkam, Chennai since 2004. Each impeller, casing and shaft is built for the gas and temperature it will see, performance tested as per IS 4894 or BS 848 Part I, and balanced to grade G 6.3 or G 2.5 as per ISO 21940-11, with the records supplied with the fan. We also replace rotors and retrofit existing fans of any make.

ID Fan for related applications

Industries

Services on this fan

ID Fan for NPK granulation plant dryers: send us your duty point

Flow, pressure, gas temperature and the fuel are enough to start a selection.