Induced Draft (ID) Fan · designed and built in Chennai

Induced Draft (ID) Fan for Gas Fired Crematoria

The ID fan on a gas fired crematorium draws gas from the afterburner through dilution and the scrubber or filter. Gas firing is clean, so dust is low, but the gas volume swings sharply between preheat, the main burn and calcination, and fast draft control decides how well the fan does its job.

Send your duty pointCall +91 91766 67102
50 to 75°C wet; 150 to 200°C with dilution and bag filterGas temperature, normal
1.03 kg/m³Gas density at 70°C
Backward curvedBlade form

How gas fired crematoria work

A gas fired crematorium uses LPG, natural gas or piped gas burners in both the primary and secondary chambers. The primary burner preheats the hearth to about 650°C and starts the cremation; once the body is burning, its own fat and tissue release heat and the burner turns down. The secondary burner holds the afterburner at about 850 to 1,000°C. A cycle takes about 60 to 90 minutes, and two or three cremations can be done back to back without cooling the chamber. Flue gas leaving the afterburner is cooled with dilution air or a water quench, passed through a scrubber or bag filter, and sent to a chimney by an ID fan. Burner blowers and a separate air fan supply combustion and secondary air.

Where the ID fan sits

  1. Primary chamber
  2. Afterburner
  3. Dilution air or quench
  4. Wet scrubber or bag filter
  5. ID fan
  6. Chimney

The fan is after the gas cleaning. If the plant uses dilution air to cool the gas to 150 to 200°C ahead of a bag filter, the fan is a dry, warm duty and the dilution air increases its volume two to three times. If it uses a water quench and scrubber, the fan sees saturated gas at 50 to 75°C. Suction is typically 120 to 250 mmWC, covering the chambers, quench and scrubber.

Gas at the ID fan

Gas temperature, normal50 to 75°C wet; 150 to 200°C with dilution and bag filter
Maximum or upset300 to 400°C if dilution or quench fails
Dust at the fanVery low; fine ash and calcium phosphate particles
Moisture and dew pointGas firing and the body give 15 to 20% water vapour before any quench
Corrosive speciesHCl from coffin furnishings and plastics; mercury vapour
Density at the design temperatureAbout 1.03 kg/m³ at 70°C, 86% of standard air. Pressure developed and power drawn scale with density, so the fan is selected at this condition and the motor is checked at the coldest operating or start-up condition.

ID Fan selection for gas fired crematoria

Blade formBackward curved, on low dust gas
Material of constructionSS 316 for wet duty; mild steel for dry gas kept above dew point
Drive and arrangementDirect drive, arrangement 4 or 8
Bearings and coolingStandard bearings; cooling disc for the dry duty
Flow controlVariable speed drive on primary chamber pressure
Also specifiedCasing drain, high-temperature trip and a door switch signal to the drive

What this ID fan has to cope with

Dilution air doubles the fan

Cooling with ambient air is simple but adds two or three times the flue gas volume, so the fan and bag filter become much larger. Comparing a quench or a heat exchanger against dilution at the design stage often gives a smaller fan with lower power.

Rapid volume swing in the main burn

Shortly after charging, the body releases volatiles quickly and the gas volume and temperature jump within a minute or two. If draft is held by a slow damper, the primary chamber goes positive and smoke leaks from the door seals. A variable speed drive responding to chamber pressure within a few seconds holds suction through the peak.

Mercury and acid in wet duty

Mercury from dental amalgam and HCl from coffin linings end up in the scrubber liquor and in the droplets that are carried to the fan. Stainless steel, usually SS 316, resists the acid, a mist eliminator keeps liquor off the impeller, and a casing drain stops liquid pooling at the scroll bottom between cremations.

Energy and control

Gas fired crematoria burn fuel mainly to heat air, so every cubic metre of excess air drawn through costs gas. Draft control on a variable speed drive, holding a small fixed suction rather than a large one, reduces air ingress at doors and peepholes. Between cremations the fan can run at minimum speed, which keeps the chamber warm and cuts both fuel and power.

ID fan and FD fan in gas fired crematoria

ID fanFD fan
PositionAfter quench or dilution and gas cleaningBeside the cremator
What it handlesCooled flue gas, wet or dryAmbient air
Temperature at the fan50 to 75°C wet, 150 to 200°C dryAmbient
Main design concernVolume swing and door-open draftAir split through the cycle
ControlChamber pressureChamber oxygen or temperature

See also the Forced Draft (FD) Fan for gas fired crematoria.

Questions buyers ask

What size ID fan does a gas fired crematorium need?

It depends on the gas flow from the chambers and on the cooling method. With dilution air the flow at the fan is two to three times the flue gas from the chambers; with a quench or heat exchanger it is much smaller. Draft at the chamber and the gas cleaning resistance set the pressure.

Should the ID fan on an LPG crematorium be stainless steel?

If a wet scrubber is used, yes, because the gas leaving it is saturated and acidic, and an LPG crematorium often stands idle overnight with the casing cold. If the gas is cooled with dilution air and kept dry through a bag filter, mild steel is usually adequate, provided the fan is purged warm before shutdown.

Why does smoke come out when the crematorium door opens?

The ID fan cannot add suction fast enough when cold air rushes in through the open door, so the chamber briefly goes positive. A variable speed drive that receives a door-open signal and ramps up immediately, together with correct fan sizing for the door-open flow, keeps the chamber negative and the hall free of smoke.

Information needed to quote an ID fan for gas fired crematoria

  1. Duty point. Gas volume in m³/h or Am³/h at the fan inlet and the static pressure the fan must develop, with the margin you want on each.
  2. Gas condition. Normal and maximum gas temperature at the fan, dust loading after the collector, moisture and any acid gases such as SO₂ or HCl.
  3. System. Boiler or furnace capacity and fuel, collector type and its pressure drop, and the existing fan curve or nameplate if this is a replacement.
  4. Mechanical. Drive arrangement, flow control (damper, inlet vanes or variable speed drive), rotation and discharge orientation, and a layout drawing or site photograph.
  5. Cooling method. Dilution air, water quench or heat exchanger, and the gas temperature after it.
  6. Burner ratings. Primary and secondary burner capacity and the fuel.

Built and tested in Chennai

Adroit Fantech Engineers has designed and manufactured industrial fans at Ayanambakkam, Chennai since 2004. Each impeller, casing and shaft is built for the gas and temperature it will see, performance tested as per IS 4894 or BS 848 Part I, and balanced to grade G 6.3 or G 2.5 as per ISO 21940-11, with the records supplied with the fan. We also replace rotors and retrofit existing fans of any make.

ID Fan for related applications

Industries

Services on this fan

ID Fan for gas fired crematoria: send us your duty point

Flow, pressure, gas temperature and the fuel are enough to start a selection.

Get a quote