13, Galaxy Road, Ponniamman Nagar, Ayanambakkam, Chennai 600 095 +91 91766 67102  |  +91 91766 67103  |  marketing@adroitfantech.com
Home › Applications › ID Fan › Catalytic Oxidisers

Induced Draft (ID) Fan · designed and built in Chennai

Induced Draft (ID) Fan for Catalytic Oxidisers

The ID fan on a catalytic oxidiser pulls the treated gas from the catalyst bed through the heat exchanger cold side and sends it to the stack, keeping the whole unit and the collection hoods under suction. The gas is hot, clean air with traces of combustion products, so the design turns on thermal growth and catalyst-dust fines, not erosion.

Send your duty pointCall +91 91766 67102
150 to 250°C after the heat exchangerGas temperature, normal
0.75 kg/m³Gas density at 200°C
Backward curvedBlade form

How catalytic oxidisers work

A catalytic oxidiser destroys solvent vapours in process exhaust from coating lines, printing presses, pharma reactors and dryers. The solvent-laden air, usually below 25% of the lower explosive limit, is collected by a process fan and passed through a plate or shell-and-tube heat exchanger, where it is preheated by the treated gas. A small gas or electric preheater lifts it to the catalyst light-off temperature, typically 250 to 350°C, and the VOCs oxidise on a precious metal or metal oxide catalyst, raising the gas by 20 to 30°C for every gram per cubic metre of solvent. The hot, clean gas returns through the exchanger and leaves at 150 to 250°C. Units use either a forced draft process fan ahead of the exchanger, an induced draft fan after it, or both on larger systems.

Where the ID fan sits

  1. VOC capture hoods
  2. Heat exchanger, cold side
  3. Preheater
  4. Catalyst bed
  5. Heat exchanger, hot side
  6. ID fan
  7. Stack

In the induced draft arrangement the fan is the last item before the stack. Upstream it has the capture ductwork, both passes of the heat exchanger, the preheater and the catalyst bed, whose resistance rises as the catalyst ages or blinds with particulate. Total suction is usually 250 to 450 mmWC. Placing the fan here keeps leaks inward, so solvent-laden air cannot escape into the plant, and keeps the fan away from flammable vapour, which by this point has been destroyed.

Gas at the ID fan

Gas temperature, normal150 to 250°C after the heat exchanger
Maximum or upset350 to 450°C if a solvent slug overheats the bed or the exchanger is bypassed
Dust at the fanVery low; fine catalyst attrition dust and ceramic fibre from insulation
Moisture and dew pointA few percent water vapour from combustion of the solvent; well above dew point
Corrosive speciesHCl or HBr if chlorinated or brominated solvents reach the unit; acid condensation at shutdown
Density at the design temperatureAbout 0.75 kg/m³ at 200°C, 63% of standard air. Pressure developed and power drawn scale with density, so the fan is selected at this condition and the motor is checked at the coldest operating or start-up condition.

ID Fan selection for catalytic oxidisers

Blade formBackward curved, for efficiency on clean, warm gas
Material of constructionMild steel for normal duty; SS 304 or SS 316 where halogenated solvents produce acid gas
Drive and arrangementBelt or direct drive, arrangement 9 or 8, casing insulated and free to expand
Bearings and coolingShaft cooling disc and heat slinger; plain rolling bearings below about 250°C
Flow controlVariable speed drive holding suction at the capture hoods or a set point upstream of the exchanger
Also specifiedRated for the upset temperature; inspection door and casing drain for acid condensate

What this ID fan has to cope with

Rising pressure drop as the catalyst blinds

Silicones, phosphorus and fine particulate coat the catalyst and the exchanger plates, and the bed resistance climbs over months. A fan selected at clean-bed resistance runs out of pressure and capture at the hoods falls off. Selecting with a margin for the fouled bed, and running on speed control, lets the fan hold capture through the cleaning interval.

Temperature excursion on a solvent spike

A sudden rise in solvent concentration can push the bed outlet well above design and, with the exchanger bypass open, send hotter gas to the fan. The impeller stress and the bearing cooling are checked at the bypass temperature, and the fan is interlocked with the high-temperature dilution damper.

Acid condensate from halogenated solvents

Where dichloromethane or other chlorinated solvents reach the oxidiser, the exhaust carries HCl. On shutdown the casing cools below the dew point and pitting starts at the bottom of the scroll. Stainless construction, a casing drain and a post-purge with warm air reduce the attack.

Energy and control

Process exhaust volume often follows the production line, with coaters, presses or dryers coming on and off. A variable speed drive that holds hood suction lets the fan follow the real exhaust, and lower flow raises the residence time and reduces preheater fuel. When solvent load is high the oxidiser can be self-sustaining, and every unnecessary cubic metre of air pulled through it costs heat and fan power.

ID fan and FD fan in catalytic oxidisers

ID fanFD fan
PositionAfter the heat exchanger, before the stackBefore the heat exchanger and catalyst
What it handlesTreated, clean gasSolvent-laden process air
Temperature at the fan150 to 250°C, higher on bypassAmbient to about 60°C
Main design concernUpset temperature and fouled-bed resistanceSpark resistance and vapour tightness
ControlHood suctionHood suction and LEL dilution

See also the Forced Draft (FD) Fan for catalytic oxidisers.

Questions buyers ask

Does a catalytic oxidiser need an ID fan or an FD fan?

Either can work. An induced draft fan after the heat exchanger keeps the unit and the ducts under suction and handles destroyed, clean gas. A forced draft fan ahead of the unit handles cold, solvent-laden air and puts the oxidiser under pressure. Larger catalytic oxidisers often use both, with the ID fan controlling hood suction.

What temperature does the exhaust fan on a catalytic oxidiser see?

After a recuperative heat exchanger the treated gas from a catalytic oxidiser is usually 150 to 250°C at the fan. The fan must also be checked at the bypass condition, where hot gas from the catalyst bed goes straight to the stack, which can reach 350 to 450°C for short periods during a solvent spike.

Why does catalytic oxidiser fan pressure rise over time?

Catalyst poisons such as silicones and phosphorus, and fine particulate that passes the inlet filter, gradually coat the catalyst bed and the exchanger surfaces. The system resistance rises until the catalyst is washed, regenerated or replaced. The fan pressure should include a fouled-bed allowance so that capture at the hoods holds through the cleaning interval.

Information needed to quote an ID fan for catalytic oxidisers

  1. Duty point. Gas volume in m³/h or Am³/h at the fan inlet and the static pressure the fan must develop, with the margin you want on each.
  2. Gas condition. Normal and maximum gas temperature at the fan, dust loading after the collector, moisture and any acid gases such as SO₂ or HCl.
  3. System. Boiler or furnace capacity and fuel, collector type and its pressure drop, and the existing fan curve or nameplate if this is a replacement.
  4. Mechanical. Drive arrangement, flow control (damper, inlet vanes or variable speed drive), rotation and discharge orientation, and a layout drawing or site photograph.
  5. Solvent and capture data. Solvent types, typical and peak concentration as % LEL, and any halogenated or silicone-bearing compounds.
  6. Heat exchanger and bypass. Exchanger pressure drop clean and fouled, and the gas temperature with the hot-side bypass fully open.

Built and tested in Chennai

Adroit Fantech Engineers has designed and manufactured industrial fans at Ayanambakkam, Chennai since 2004. Each impeller, casing and shaft is built for the gas and temperature it will see, performance tested as per IS 4894 or BS 848 Part I, and balanced to grade G 6.3 or G 2.5 as per ISO 21940-11, with the records supplied with the fan. We also replace rotors and retrofit existing fans of any make.

ID Fan for related applications

Industries

Services on this fan

ID Fan for catalytic oxidisers: send us your duty point

Flow, pressure, gas temperature and the fuel are enough to start a selection.

Get a quote