Induced Draft (ID) Fan for Coconut Shell Fired Thermic Fluid Heaters

The ID fan on a coconut shell fired thermic fluid heater handles little ash, but that ash is a fine, potassium-rich fume that sticks and corrodes. Hot, fast-burning shell also gives sharp swings in gas volume, so deposits and responsive draft control decide its design.

Send your duty pointCall +91 91766 67102
200 to 230°C after the air preheaterGas temperature, normal
0.73 kg/m³Gas density at 215°C
Backward curved with smooth bladesBlade form

How coconut shell fired thermic fluid heaters work

Coconut shell fired thermic fluid heaters are used in desiccated coconut, coconut oil, coir and food processing plants and in textile units near coconut-growing areas. Shell is a dense, hard fuel with low moisture, typically 8 to 15%, a calorific value of about 4,000 to 4,500 kcal/kg and only 1 to 3% ash, but that ash is rich in potassium and chlorides. It burns hot and fast on a fixed or reciprocating grate, with high flame temperatures close to the coil. Flue gas leaves the coil at 330 to 380°C, passes an air preheater and cyclone, and reaches the ID fan and chimney. The FD fan supplies undergrate air; overfire air comes from a secondary fan or natural draft ports.

Where the ID fan sits

  1. Shell grate
  2. Radiant and convective coils
  3. Air preheater
  4. Cyclone
  5. ID fan
  6. Chimney

The fan sits after the cyclone at the chimney base, handling gas at about 200 to 230°C after the air preheater. The cyclone catches coarse ash and char, but the potassium and chloride fume is too fine for it and passes to the fan. Suction is typically 80 to 160 mmWC on heaters of 1 to 4 million kcal/h. Shell burns quickly, so heat release and gas volume rise sharply after each charge, and the fan must follow without letting the furnace go positive.

Gas at the ID fan

Gas temperature, normal200 to 230°C after the air preheater
Maximum or upsetUp to 350°C on hard firing or with fouled coils
Dust at the fanLow quantity; fine potassium and chloride fume with some char
Moisture and dew pointLow fuel moisture; water dew point well below fan temperature
Corrosive speciesChlorides in the fume; corrosive when deposits absorb moisture at shutdown
Density at the design temperatureAbout 0.73 kg/m³ at 215°C, 61% of standard air. Pressure developed and power drawn scale with density, so the fan is selected at this condition and the motor is checked at the coldest operating or start-up condition.

ID Fan selection for coconut shell fired thermic fluid heaters

Blade formBackward curved with smooth blades, or radial tipped where deposits are heavy
Material of constructionMild steel casing; corrosion-resistant steel impeller where chloride deposits stay wet between runs
Drive and arrangementDirect coupled or belt driven
Bearings and coolingPedestal bearings with cooling disc
Flow controlVariable speed drive on furnace draft with fast response
Also specifiedInspection door, casing drain, and backup power with the oil pump

What this ID fan has to cope with

Sticky alkali deposits

Potassium and chloride fume from shell ash is fine enough to pass the cyclone and condenses as a sticky layer on blades and the inlet cone. Build-up is uneven and causes vibration. Smooth blades, an inspection door and regular cleaning keep it under control.

Corrosion during idle periods

Many coconut processors run one or two shifts, and the heater stands idle overnight. When it stops, chloride deposits on the fan absorb moisture from the air and pit the steel within weeks. Cleaning before long stops, casing insulation and a corrosion-resistant impeller reduce the damage.

Fast firing and draft swings

Dry shell flares up quickly after each charge, and the gas volume rises sharply within a minute. If the fan cannot follow, the furnace goes positive and the oil overheats. A fan with reserve pressure and a fast-acting variable speed drive keep the furnace under suction through each charge.

Energy and control

Shell heaters often run in one or two shifts and at varying load. A variable speed drive on furnace draft saves power and handles the fast swings of shell combustion better than a damper. Even, frequent charging of smaller quantities of shell smooths combustion, improves heater efficiency and lowers fan power at the same time.

ID fan and FD fan in coconut shell fired thermic fluid heaters

ID fanFD fan
PositionAfter the cyclone, before the chimneyBefore the air preheater, under the grate
What it handlesFlue gas with fine potassium and chloride fumeAmbient air
Temperature at the fan200 to 230°CAmbient
Main design concernSticky deposits and corrosionClinker and oil overheating
ControlFurnace draftOil outlet temperature

See also the Forced Draft (FD) Fan for coconut shell fired thermic fluid heaters.

Questions buyers ask

Why do deposits form on the ID fan of a coconut shell heater?

Coconut shell ash is rich in potassium and chlorides, which form a very fine fume in the hot furnace. It passes the cyclone and sticks to the blades and inlet cone as the gas cools. Regular cleaning, smooth blades and an inspection door control the build-up and the vibration it causes.

Does coconut shell cause corrosion in the ID fan?

It can. Chloride deposits absorb moisture when the heater is idle overnight or over weekends and pit the steel. Cleaning the fan before long stops, insulating the casing, and using a corrosion-resistant impeller on plants with long idle periods all help.

How hot is the gas at the ID fan of a coconut shell fired thermic fluid heater?

Typically 200 to 230°C with the air preheater working, and up to about 350°C on hard firing or with fouled coils. The fan is sized on the measured gas temperature and volume, with shaft cooling and bearings selected for the hot case.

Information needed to quote an ID fan for coconut shell fired thermic fluid heaters

  1. Duty point. Gas volume in m³/h or Am³/h at the fan inlet and the static pressure the fan must develop, with the margin you want on each.
  2. Gas condition. Normal and maximum gas temperature at the fan, dust loading after the collector, moisture and any acid gases such as SO₂ or HCl.
  3. System. Boiler or furnace capacity and fuel, collector type and its pressure drop, and the existing fan curve or nameplate if this is a replacement.
  4. Mechanical. Drive arrangement, flow control (damper, inlet vanes or variable speed drive), rotation and discharge orientation, and a layout drawing or site photograph.
  5. Firing pattern. Manual or automatic feeding, shell firing rate, and shifts per day.
  6. Deposit history. How often the present fan is cleaned and photographs of the deposits.

Built and tested in Chennai

Adroit Fantech Engineers has designed and manufactured industrial fans at Ayanambakkam, Chennai since 2004. Each impeller, casing and shaft is built for the gas and temperature it will see, performance tested as per IS 4894 or BS 848 Part I, and balanced to grade G 6.3 or G 2.5 as per ISO 21940-11, with the records supplied with the fan. We also replace rotors and retrofit existing fans of any make.

ID Fan for related applications

Industries

Services on this fan

ID Fan for coconut shell fired thermic fluid heaters: send us your duty point

Flow, pressure, gas temperature and the fuel are enough to start a selection.

Get a quote