Induced Draft (ID) Fan for Rice Husk Fired Thermic Fluid Heaters

The ID fan on a rice husk fired thermic fluid heater faces silica ash erosion at a higher gas temperature than a husk boiler, because the oil leaves the coil hot. That combination, abrasive ash at 200 to 250°C or more, decides which wear materials will actually last.

Send your duty pointCall +91 91766 67102
200 to 240°C after the air preheaterGas temperature, normal
0.72 kg/m³Gas density at 220°C
Radial tipped with replaceable liners after a multicycloneBlade form

How rice husk fired thermic fluid heaters work

Rice husk fired thermic fluid heaters are common in rice mills, parboiling plants, solvent extraction units and food processors close to husk supply. Husk is fed by screw or pneumatically onto an inclined step grate, a reciprocating grate or into a small fluidised bed, and much of it burns in suspension. It has a calorific value of about 3,000 to 3,400 kcal/kg and 18 to 22% ash that is almost pure silica. The flue gas leaves the coil at 330 to 380°C, passes an air preheater, and goes through a cyclone or multicyclone, with a bag filter on newer units, to the ID fan and chimney. The FD fan supplies grate or bed air and a separate blower often handles pneumatic husk feeding.

Where the ID fan sits

  1. Husk feeder and grate
  2. Radiant and convective coils
  3. Air preheater
  4. Multicyclone
  5. Bag filter where fitted
  6. ID fan
  7. Chimney

On most heaters the fan follows a multicyclone, and many small units have no bag filter, so the fan handles hundreds of mg/Nm³ to a few g/Nm³ of fine silica. Gas reaches it at about 200 to 240°C with the air preheater working, and well above 300°C when the preheater is bypassed or fouled. Suction is typically 100 to 180 mmWC on heaters of 1 to 6 million kcal/h, made up of furnace draft, the coils, the air preheater and the multicyclone.

Gas at the ID fan

Gas temperature, normal200 to 240°C after the air preheater
Maximum or upset300 to 360°C with preheater bypass or fouled coil
Dust at the fanFine, angular silica ash and some char; several hundred mg/Nm³ to a few g/Nm³ after a multicyclone
Moisture and dew pointHusk moisture of 8 to 12%; water dew point well below fan temperature
Corrosive speciesLow sulphur; minor chlorides from some husk
Density at the design temperatureAbout 0.72 kg/m³ at 220°C, 60% of standard air. Pressure developed and power drawn scale with density, so the fan is selected at this condition and the motor is checked at the coldest operating or start-up condition.

ID Fan selection for rice husk fired thermic fluid heaters

Blade formRadial tipped with replaceable liners after a multicyclone; backward curved with liners after a bag filter
Material of constructionMild steel casing with scroll liners; impeller in wear-resistant plate suited to the operating temperature, or hard-faced mild steel
Drive and arrangementDirect coupled or belt driven, at moderate speed to limit tip speed
Bearings and coolingPedestal bearings with cooling disc
Flow controlVariable speed drive on furnace draft
Also specifiedBolted wear liners, inspection door, and backup power for the fan and oil pump

What this ID fan has to cope with

Wear plate softening at heater temperatures

Quenched wear-resistant plates lose hardness if they run for long periods above about 250°C, and husk thermic fluid heaters can reach that when the air preheater is bypassed. Using a wear grade rated for the temperature, or hard-facing on a heat-tolerant base plate, keeps the liner working in the hot case.

Silica erosion after a multicyclone

A multicyclone removes coarse ash but passes much of the fine silica, which wears the blade leading edges and the scroll near the cut-off. Lower tip speed, radial tipped blades with replaceable liners, and a scheduled liner change keep the fan running through the season.

Glowing char and air preheater fires

Unburnt husk char can carry over glowing and lodge in the air preheater or fan. Deposits that smoulder can damage the casing and bag filter. Good overfire air, a spark arrestor and a cleanout door on the fan reduce the risk.

Power failure with hot oil

If power fails, the oil circulation pump stops while the furnace and refractory are still hot, and oil in the coil can overheat and crack. Husk heaters with a fluidised bed hold even more stored heat. The ID fan and pump on backup power let the furnace be cooled while the oil keeps moving.

Energy and control

Husk heaters in rice mills run with the milling season and follow parboiling or drying demand, often at part load. A variable speed drive on draft saves power and, by lowering speed, also reduces erosion. Keeping the air preheater clean holds the fan gas temperature down, cuts the gas volume and protects the wear materials.

ID fan and FD fan in rice husk fired thermic fluid heaters

ID fanFD fan
PositionAfter the multicyclone or bag filter, before the chimneyBefore the air preheater, under the grate or bed
What it handlesFlue gas with abrasive silica ashAmbient air
Temperature at the fan200 to 240°C, above 300°C upsetAmbient
Main design concernErosion at elevated temperatureAir split on a light husk bed
ControlFurnace draftOil outlet temperature

See also the Forced Draft (FD) Fan for rice husk fired thermic fluid heaters.

Questions buyers ask

Why does the ID fan wear out so fast on a rice husk thermic fluid heater?

Husk ash is almost pure silica and is very abrasive. Most heaters use a multicyclone, which lets fine silica reach the fan, and the gas is hotter than on a husk boiler. Wear plate, liners, lower tip speed and a bag filter all extend fan life.

What temperature does a husk fired thermic fluid heater ID fan see?

About 200 to 240°C with the air preheater working, and above 300°C when the preheater is bypassed, fouled or leaking. That is noticeably hotter than on a husk fired steam boiler of similar size. Wear materials, shaft cooling and bearings are selected for the hotter case, not only the normal one.

Is a radial or backward curved ID fan better for a husk thermic fluid heater?

After a multicyclone, radial tipped blades with replaceable liners last longer and tolerate wear without large loss of performance. After a bag filter, a lined backward curved fan is more efficient. The choice follows the dust collector and the measured dust at the fan inlet.

Information needed to quote an ID fan for rice husk fired thermic fluid heaters

  1. Duty point. Gas volume in m³/h or Am³/h at the fan inlet and the static pressure the fan must develop, with the margin you want on each.
  2. Gas condition. Normal and maximum gas temperature at the fan, dust loading after the collector, moisture and any acid gases such as SO₂ or HCl.
  3. System. Boiler or furnace capacity and fuel, collector type and its pressure drop, and the existing fan curve or nameplate if this is a replacement.
  4. Mechanical. Drive arrangement, flow control (damper, inlet vanes or variable speed drive), rotation and discharge orientation, and a layout drawing or site photograph.
  5. Dust collector. Multicyclone, bag filter or both, and the dust measured at the fan inlet.
  6. Wear history. Life of the present impeller and liners and photographs of worn parts.

Built and tested in Chennai

Adroit Fantech Engineers has designed and manufactured industrial fans at Ayanambakkam, Chennai since 2004. Each impeller, casing and shaft is built for the gas and temperature it will see, performance tested as per IS 4894 or BS 848 Part I, and balanced to grade G 6.3 or G 2.5 as per ISO 21940-11, with the records supplied with the fan. We also replace rotors and retrofit existing fans of any make.

ID Fan for related applications

Industries

Services on this fan

ID Fan for rice husk fired thermic fluid heaters: send us your duty point

Flow, pressure, gas temperature and the fuel are enough to start a selection.

Get a quote