13, Galaxy Road, Ponniamman Nagar, Ayanambakkam, Chennai 600 095 +91 91766 67102  |  +91 91766 67103  |  marketing@adroitfantech.com
Home › Applications › FD Fan › Coconut Shell Fired Thermic Fluid Heaters

Forced Draft (FD) Fan · designed and built in Chennai

Forced Draft (FD) Fan for Coconut Shell Fired Thermic Fluid Heaters

The FD fan on a coconut shell fired thermic fluid heater supplies undergrate air through the air preheater. Shell burns hot on a dense bed, so the FD fan must give enough air through the bed without driving the grate temperature high enough to fuse the potassium-rich ash into clinker.

Send your duty pointCall +91 91766 67102
Ambient, 25 to 45°CAir temperature at the fan
1.13 kg/m³Air density at 40°C
Backward curvedBlade form

How coconut shell fired thermic fluid heaters work

Coconut shell fired thermic fluid heaters are used in desiccated coconut, coconut oil, coir and food processing plants and in textile units near coconut-growing areas. Shell is a dense, hard fuel with low moisture, typically 8 to 15%, a calorific value of about 4,000 to 4,500 kcal/kg and only 1 to 3% ash, but that ash is rich in potassium and chlorides. It burns hot and fast on a fixed or reciprocating grate, with high flame temperatures close to the coil. Flue gas leaves the coil at 330 to 380°C, passes an air preheater and cyclone, and reaches the ID fan and chimney. The FD fan supplies undergrate air; overfire air comes from a secondary fan or natural draft ports.

Where the FD fan sits

  1. Inlet screen
  2. FD fan
  3. Air preheater
  4. Undergrate plenum
  5. Shell grate
  6. Furnace

The fan pushes ambient air through the air preheater, which heats it to 150 to 200°C, and into the plenum under the grate. Shell forms a denser, deeper bed than husk or wood chips, so the grate resistance is higher, and the fan works at about 80 to 150 mmWC. Overfire air enters through ports above the grate from a secondary fan or by natural draft, and the FD fan is interlocked with the firing door on manually fed heaters.

Air at the FD fan

Air temperature at the fanAmbient, 25 to 45°C
Air after the preheater150 to 200°C, downstream of the fan
DustShell dust and fibre near the fuel store
Pressure at the fan outlet80 to 150 mmWC
Grate conditionsDense, hot bed; ash fuses at low temperature
Density at the design temperatureAbout 1.13 kg/m³ at 40°C, 94% of standard air. Pressure developed and power drawn scale with density, so the fan is selected at this condition and the motor is checked at the coldest operating or start-up condition.

FD Fan selection for coconut shell fired thermic fluid heaters

Blade formBackward curved
Material of constructionMild steel
Drive and arrangementDirect coupled
Bearings and coolingStandard bearings
Flow controlVariable speed drive on oil outlet temperature
Also specifiedInlet screen and firing door interlock

What this FD fan has to cope with

Clinker on the grate

Potassium-rich shell ash melts at relatively low temperature. Too much hot undergrate air drives the bed temperature up and forms clinker that blocks the grate openings and starves parts of the bed. Controlling the air flow to the burning rate, and not over-preheating the air, keep the bed below its clinkering temperature.

Oil overheating

Dry shell burns fast after each charge and can overheat the oil film on the coil. FD fan control linked to oil outlet temperature cuts the undergrate air quickly to slow the fire, and an oil flow interlock stops the fan if circulation is lost.

Dense bed resistance

A deep bed of dense shell adds resistance, and it changes as the bed burns down between charges. The FD fan needs enough pressure to push air through the bed evenly at its deepest, and a steep fan curve keeps the flow steadier as the bed resistance falls.

Energy and control

A variable speed drive on the FD fan, controlled from oil outlet temperature, saves power and gives smoother control of a fast-burning fuel than on-off firing. The correct split between undergrate and overfire air improves burnout of the shell volatiles, keeps excess air low and reduces the fume reaching the ID fan.

ID fan and FD fan in coconut shell fired thermic fluid heaters

ID fanFD fan
PositionAfter the cyclone, before the chimneyBefore the air preheater, under the grate
What it handlesFlue gas with fine potassium and chloride fumeAmbient air
Temperature at the fan200 to 230°CAmbient
Main design concernSticky deposits and corrosionClinker and oil overheating
ControlFurnace draftOil outlet temperature

See also the Induced Draft (ID) Fan for coconut shell fired thermic fluid heaters.

Questions buyers ask

Why does clinker form on a coconut shell heater grate?

Shell ash is rich in potassium, which lowers its melting point. Too much air under the grate, or air preheated too far, drives the bed hot enough to fuse the ash into clinker. Controlled undergrate air and a properly sized air preheater prevent this.

Does the FD fan on a coconut shell heater handle hot air?

No. It pushes ambient air into the air preheater, which heats it downstream on its way to the grate. The fan is a cold-air machine selected at ambient density in mild steel, with an inlet screen against shell dust.

What pressure does the FD fan need on a coconut shell fired thermic fluid heater?

Typically 80 to 150 mmWC, covering the air preheater, ducts, plenum and the dense shell bed. Deeper beds and grates with small air holes need the higher end. Send the grate data and we will calculate the duty for the coconut shell fired thermic fluid heater.

Information needed to quote an FD fan for coconut shell fired thermic fluid heaters

  1. Duty point. Combustion air quantity in m³/h or kg/h and the static pressure at the fan outlet, with the margins you want.
  2. Air condition. Site ambient temperature range and altitude, and whether the fan takes ambient air or air already heated.
  3. System. Boiler or furnace capacity and fuel, resistance of the air heater, windbox, grate or burner, and the existing fan curve or nameplate if this is a replacement.
  4. Mechanical. Drive arrangement, flow control (damper, inlet vanes or variable speed drive), noise limit, rotation and discharge orientation.
  5. Grate. Grate type and area, and the depth of the shell bed.
  6. Air preheater. Air side resistance and hot air temperature.

Built and tested in Chennai

Adroit Fantech Engineers has designed and manufactured industrial fans at Ayanambakkam, Chennai since 2004. Each impeller, casing and shaft is built for the gas and temperature it will see, performance tested as per IS 4894 or BS 848 Part I, and balanced to grade G 6.3 or G 2.5 as per ISO 21940-11, with the records supplied with the fan. We also replace rotors and retrofit existing fans of any make.

FD Fan for related applications

Industries

Services on this fan

FD Fan for coconut shell fired thermic fluid heaters: send us your duty point

Flow, pressure, air temperature and the fuel are enough to start a selection.

Get a quote