Forced Draft (FD) Fan · designed and built in Chennai

Forced Draft (FD) Fan for Tyre Curing Press Boilers

The FD fan on a tyre curing boiler supplies combustion air to the bed, grate or burner, through the air heater where one is fitted. It handles ambient air, and its job is to change airflow quickly and accurately as press demand moves the firing rate up and down.

Send your duty pointCall +91 91766 67102
Ambient, 25 to 45°CAir temperature at the fan
1.13 kg/m³Air density at 40°C
Backward curved for efficiencyBlade form

How tyre curing press boilers work

Tyre plants use steam at typically 14 to 20 bar to heat the curing presses, both through the platens or moulds and, on many presses, inside the bladder. Each press takes a large draw of steam at the start of its cure and much less afterwards, so a curing shop with dozens of presses produces a steam demand that swings sharply through the day. Larger tyre plants generally use coal or biomass fired AFBC or travelling grate boilers; smaller tyre, tube and retread plants use oil or gas fired packaged boilers. In either case the flue gas passes the boiler, economiser and air heater where fitted, then a dust collector on solid fuels, before the ID fan and chimney. The FD fan supplies combustion air to the grate, bed or burner.

Where the FD fan sits

  1. Inlet screen
  2. FD fan
  3. Air heater
  4. Air ducts
  5. Windbox or burner
  6. Furnace

The fan sits at ground level and pushes ambient air through the air heater, where fitted, into the windbox under an AFBC bed or grate, or into the burner on oil and gas boilers. On fluidised bed boilers it works against the distributor plate and bed, typically 700 to 1,100 mmWC. On packaged boilers the burner fan is often integral to the burner and handles 100 to 300 mmWC.

Air at the FD fan

Air temperature at the fanAmbient, 25 to 45°C
Air after the air heater120 to 180°C, downstream of the fan
DustClean air; carbon black and rubber dust in tyre plant air can enter an unscreened inlet
Pressure at the fan outlet100 to 300 mmWC on packaged boilers; 700 to 1,100 mmWC on AFBC
Load profileFollows the frequent press-driven swings in firing rate
Density at the design temperatureAbout 1.13 kg/m³ at 40°C, 94% of standard air. Pressure developed and power drawn scale with density, so the fan is selected at this condition and the motor is checked at the coldest operating or start-up condition.

FD Fan selection for tyre curing press boilers

Blade formBackward curved for efficiency; high-pressure radial or backward curved for AFBC beds
Material of constructionMild steel throughout
Drive and arrangementDirect coupled or direct mounted on the motor shaft
Bearings and coolingStandard pedestal or motor bearings; no cooling needed
Flow controlVariable speed drive on the combustion control loop with oxygen trim
Also specifiedInlet screen and silencer; airflow measurement in the duct for accurate ratio control

What this FD fan has to cope with

Air-fuel ratio drift through load swings

If the FD fan responds slower than the fuel feed, the boiler runs short of air at each press start and produces smoke and CO. An airflow measurement and a drive tuned to lead fuel on rising load keep the ratio correct.

Bed slumping at low load on AFBC

When press demand falls, reducing air too far can drop below minimum fluidising velocity. The FD control needs a floor on airflow, and bed compartments are taken out of service rather than starving the whole bed.

Carbon black and rubber dust

Tyre plant air carries fine carbon black and rubber particles that can coat the impeller and choke inlet screens. Taking air from a clean location and cleaning the screen on a schedule prevents unbalance and loss of flow.

Energy and control

The FD fan follows the same rapid load pattern as the ID fan. A variable speed drive with oxygen trim keeps excess air low through the swings, which saves both fan power and fuel. On AFBC boilers the high bed pressure makes the FD fan one of the largest auxiliary loads, so its efficiency at the typical part-load point matters more than at the rated point.

ID fan and FD fan in tyre curing press boilers

ID fanFD fan
PositionAfter the dust collector or economiser, before the chimneyAhead of the air heater, feeding bed, grate or burner
What it handlesFlue gas, with fly ash on solid fuelsClean ambient air
Temperature at the fan150 to 190°C, up to 240°C upsetAmbient, 25 to 45°C
Main design concernDraft through rapid load swingsAir-fuel ratio through rapid load swings
ControlFurnace draft, following the FD fanSteam header pressure with oxygen trim

See also the Induced Draft (ID) Fan for tyre curing press boilers.

Questions buyers ask

How fast should the FD fan respond on a tyre curing boiler?

Fast enough to keep the air-fuel ratio within limits as firing rises at press start. In practice this means drive ramp times of a few seconds, airflow measurement and a control strategy where air leads fuel on rising load and lags it on falling load.

Does the FD fan on an AFBC tyre plant boiler need high pressure?

Yes. The fluidised bed and distributor plate need typically 700 to 1,100 mmWC at the fan outlet, far more than a grate or burner. This needs a high-pressure impeller and a robust motor.

Can the existing FD fan be retrofitted with a VFD?

Usually yes, if the motor is suitable for variable speed duty. We check the fan curve against the actual operating range and confirm that the impeller is not close to a resonance in the new speed range.

Information needed to quote an FD fan for tyre curing press boilers

  1. Duty point. Combustion air quantity in m³/h or kg/h and the static pressure at the fan outlet, with the margins you want.
  2. Air condition. Site ambient temperature range and altitude, and whether the fan takes ambient air or air already heated.
  3. System. Boiler or furnace capacity and fuel, resistance of the air heater, windbox, grate or burner, and the existing fan curve or nameplate if this is a replacement.
  4. Mechanical. Drive arrangement, flow control (damper, inlet vanes or variable speed drive), noise limit, rotation and discharge orientation.
  5. Firing system. AFBC, grate or oil and gas burner, with windbox or burner pressure.
  6. Air measurement. Whether the duct has an airflow measurement and oxygen trim.

Built and tested in Chennai

Adroit Fantech Engineers has designed and manufactured industrial fans at Ayanambakkam, Chennai since 2004. Each impeller, casing and shaft is built for the gas and temperature it will see, performance tested as per IS 4894 or BS 848 Part I, and balanced to grade G 6.3 or G 2.5 as per ISO 21940-11, with the records supplied with the fan. We also replace rotors and retrofit existing fans of any make.