Forced Draft (FD) Fan · designed and built in Chennai

Forced Draft (FD) Fan for Carbon Fibre Oxidation Ovens

The FD fan on a carbon fibre oxidation oven is the fresh air supply fan. It brings in filtered ambient air, usually through a heat exchanger that recovers heat from the oxidiser exhaust, to replace the air bled from each zone. Clean, filtered air and a stable flow balance with the exhaust decide its design.

Send your duty pointCall +91 91766 67102
Ambient, 25 to 45°C, filteredAir temperature at the fan
1.13 kg/m³Air density at 40°C
Backward curved for efficiency on cleanBlade form

How carbon fibre oxidation ovens work

Carbon fibre is made by first stabilising PAN precursor tow in air at about 200 to 300°C, in a series of oxidation ovens where the tow passes back and forth many times on rollers. The reaction is exothermic and releases hydrogen cyanide, ammonia, carbon monoxide, water vapour and tarry oligomers. Large recirculation fans drive hot air across the tow at controlled velocity, and the ovens are heated by gas burners or electric heaters, often indirectly. To keep toxic and flammable species far below safe limits, a bleed of oven air is continuously exhausted and replaced with fresh air. The exhaust (ID) fan takes this bleed to a thermal oxidiser, and a fresh air supply fan, which serves as the FD fan, replaces it.

Where the FD fan sits

  1. Inlet filter
  2. FD fan
  3. Heat recovery exchanger
  4. Supply air duct
  5. Zone make-up dampers
  6. Oven zones

The supply fan sits outside the oven enclosure, takes ambient air through a filter and pushes it through the heat recovery exchanger, where the air is preheated, then into the make-up ports of each zone. The oven's own recirculation fans then move the air across the tow. The supply fan works against the filter, exchanger and duct, typically 100 to 250 mmWC. Supply and exhaust are balanced so the oven stays slightly negative.

Air at the FD fan

Air temperature at the fanAmbient, 25 to 45°C, filtered
Air after heat recovery100 to 200°C, downstream of the fan
DustFiltered air; fibre fly from the line and outdoor dust must not reach the tow
Pressure at the fan outletTypically 100 to 250 mmWC
Balance requirementSupply set slightly below exhaust so the oven stays negative
Density at the design temperatureAbout 1.13 kg/m³ at 40°C, 94% of standard air. Pressure developed and power drawn scale with density, so the fan is selected at this condition and the motor is checked at the coldest operating or start-up condition.

FD Fan selection for carbon fibre oxidation ovens

Blade formBackward curved for efficiency on clean, filtered air
Material of constructionMild steel, painted, or galvanised; stainless steel where the duct is shared with exhaust heat recovery
Drive and arrangementDirect mounted or direct coupled
Bearings and coolingStandard motor or pedestal bearings; no cooling needed
Flow controlVariable speed drive tracking the exhaust flow to hold oven pressure
Also specifiedInlet filter with pressure drop monitoring, airflow measurement and a non-return damper

What this FD fan has to cope with

Dust and fibre in the supply air

Particles in the make-up air land on the tow and become defects in the fibre. Fine filtration on the inlet and a fan that does not shed paint or rust into the air protect product quality.

Imbalance between supply and exhaust

If the supply fan delivers more than the exhaust removes, the oven goes positive and HCN escapes at the tow slots. Flow measurement on both fans and a control that tracks exhaust flow keep the oven negative.

Exchanger leakage

A leak in the heat recovery exchanger can pass oxidiser exhaust into the supply air. Pressure on the supply side is kept above the exhaust side so any leak goes outwards, and the exchanger is inspected at each shutdown.

Energy and control

The supply fan runs for the whole campaign at a flow set by the exhaust bleed. Its power is modest; the larger saving is in the heat needed to bring fresh air to oven temperature. Recovering heat from the oxidiser exhaust into the supply air, and keeping the bleed at the minimum the safety limits allow, reduce gas or electric consumption more than any change at the fan itself.

ID fan and FD fan in carbon fibre oxidation ovens

ID fanFD fan
PositionOn the exhaust bleed, ahead of the thermal oxidiserOn the fresh air supply, ahead of heat recovery
What it handlesHot air with HCN, ammonia and tarsFiltered ambient air
Temperature at the fan230 to 300°CAmbient, 25 to 45°C
Main design concernGas tightness and tar foulingClean air and supply-exhaust balance
ControlOven pressureTracks exhaust flow

See also the Induced Draft (ID) Fan for carbon fibre oxidation ovens.

Questions buyers ask

Is there a forced draft fan on a carbon fibre oxidation oven?

Not in the boiler sense. The equivalent is the fresh air supply fan that replaces the exhaust bleed. Where the ovens are gas-fired, small combustion air fans feed the burners as well. The large fans inside the oven are recirculation fans, which are a separate duty.

Does the supply air need to be preheated?

It is usually preheated by recovering heat from the oxidiser or oven exhaust. The fan stays on the cold side, ahead of the exchanger, so it handles ambient air and the heat duty falls on the exchanger.

Why must the oven stay at negative pressure?

The process releases hydrogen cyanide and other toxic gases. Negative pressure makes air leak inwards at the tow slots and doors rather than letting oven gas leak into the workplace.

Information needed to quote an FD fan for carbon fibre oxidation ovens

  1. Duty point. Combustion air quantity in m³/h or kg/h and the static pressure at the fan outlet, with the margins you want.
  2. Air condition. Site ambient temperature range and altitude, and whether the fan takes ambient air or air already heated.
  3. System. Boiler or furnace capacity and fuel, resistance of the air heater, windbox, grate or burner, and the existing fan curve or nameplate if this is a replacement.
  4. Mechanical. Drive arrangement, flow control (damper, inlet vanes or variable speed drive), noise limit, rotation and discharge orientation.
  5. Make-up rate. Fresh air flow per zone and the total exhaust bleed it must balance.
  6. Filtration. Required filter grade on the supply air.

Built and tested in Chennai

Adroit Fantech Engineers has designed and manufactured industrial fans at Ayanambakkam, Chennai since 2004. Each impeller, casing and shaft is built for the gas and temperature it will see, performance tested as per IS 4894 or BS 848 Part I, and balanced to grade G 6.3 or G 2.5 as per ISO 21940-11, with the records supplied with the fan. We also replace rotors and retrofit existing fans of any make.

FD Fan for related applications

Industries

Services on this fan

FD Fan for carbon fibre oxidation ovens: send us your duty point

Flow, pressure, air temperature and the fuel are enough to start a selection.

Get a quote