13, Galaxy Road, Ponniamman Nagar, Ayanambakkam, Chennai 600 095 +91 91766 67102  |  +91 91766 67103  |  marketing@adroitfantech.com
Home › Applications › ID Fan › Carbon Fibre Oxidation Ovens

Induced Draft (ID) Fan · designed and built in Chennai

Induced Draft (ID) Fan for Carbon Fibre Oxidation Ovens

The ID fan on a carbon fibre oxidation oven is the oven exhaust fan. It removes a controlled bleed of hot process air containing hydrogen cyanide, ammonia and tars, and holds the oven at a slight negative pressure so that no toxic gas escapes at the tow slots. Gas tightness and resistance to tar fouling decide its design.

Send your duty pointCall +91 91766 67102
230 to 300°C oven exhaust airGas temperature, normal
0.66 kg/m³Gas density at 260°C
Backward curved or radial bladedBlade form

How carbon fibre oxidation ovens work

Carbon fibre is made by first stabilising PAN precursor tow in air at about 200 to 300°C, in a series of oxidation ovens where the tow passes back and forth many times on rollers. The reaction is exothermic and releases hydrogen cyanide, ammonia, carbon monoxide, water vapour and tarry oligomers. Large recirculation fans drive hot air across the tow at controlled velocity, and the ovens are heated by gas burners or electric heaters, often indirectly. To keep toxic and flammable species far below safe limits, a bleed of oven air is continuously exhausted and replaced with fresh air. The exhaust (ID) fan takes this bleed to a thermal oxidiser, and a fresh air supply fan, which serves as the FD fan, replaces it.

Where the ID fan sits

  1. Oven zones
  2. Exhaust collection duct
  3. Tar knockout or filter
  4. Exhaust (ID) fan
  5. Thermal oxidiser
  6. Stack

The fan sits on the exhaust duct that collects bleed air from each oven zone, upstream of the thermal oxidiser in most layouts, so it pushes the exhaust into the oxidiser. It works against the zone balancing dampers, the duct and any tar knockout or filter, typically 100 to 250 mmWC. On some lines an ID fan after the oxidiser pulls the whole system instead, which keeps the oxidiser under suction but puts the fan in hot, clean gas.

Gas at the ID fan

Gas temperature, normal230 to 300°C oven exhaust air
Maximum or upsetUp to 350°C during a runaway exotherm or fibre fire in a zone
Dust at the fanLittle dust; fibre fragments and condensed tarry oligomers
Toxic and flammable speciesHCN, ammonia and CO, kept well below lower explosive limits by the bleed rate
CondensationTars condense on surfaces below about 200°C, so cold spots in the duct and fan foul quickly
Density at the design temperatureAbout 0.66 kg/m³ at 260°C, 55% of standard air. Pressure developed and power drawn scale with density, so the fan is selected at this condition and the motor is checked at the coldest operating or start-up condition.

ID Fan selection for carbon fibre oxidation ovens

Blade formBackward curved or radial bladed, with open blade passages that tolerate some tar build-up
Material of constructionStainless steel impeller and casing, commonly SS 304 or SS 316, with welded gas-tight casing joints
Drive and arrangementDirect coupled with the motor outside the gas stream; arrangement with a heat-isolated bearing pedestal
Bearings and coolingPedestal bearings with cooling disc; shaft seal of the purged or multi-ring type to stop leakage
Flow controlVariable speed drive on oven pressure, with zone dampers for balance
Also specifiedInsulated and trace-heated casing to avoid tar condensation, cleaning doors, and spark-resistant construction where required by the hazard study

What this ID fan has to cope with

Tar build-up on the impeller

Oligomers and tars condense on any surface below their dew point and bake into a hard layer. On the impeller this causes unbalance and loss of flow. Insulating the casing, keeping the gas hot through the fan and providing access for scheduled cleaning keep the fan in service.

Toxic gas leakage at the shaft

HCN at the shaft seal or casing joints is a direct hazard to operators. Welded casing seams, gasketed access doors and a purged or multi-lip shaft seal make the casing gas-tight; gas detection near the fan is normal practice.

Exotherm or fibre fire

A stopped line or broken tow can lead to a runaway reaction in a zone, raising exhaust temperature sharply. The fan and its bearings must survive the upset, and the exhaust control should hold suction rather than shut off and let toxic gas into the building.

Energy and control

Oxidation ovens run continuously for long campaigns, and the exhaust rate is set by safety limits on HCN and the need to remove reaction heat. Holding oven pressure with a variable speed drive avoids throttling losses, and keeping the bleed at the minimum safe rate reduces the fresh air that has to be heated and the gas that the thermal oxidiser must burn, which is usually the larger energy cost.

ID fan and FD fan in carbon fibre oxidation ovens

ID fanFD fan
PositionOn the exhaust bleed, ahead of the thermal oxidiserOn the fresh air supply, ahead of heat recovery
What it handlesHot air with HCN, ammonia and tarsFiltered ambient air
Temperature at the fan230 to 300°CAmbient, 25 to 45°C
Main design concernGas tightness and tar foulingClean air and supply-exhaust balance
ControlOven pressureTracks exhaust flow

See also the Forced Draft (FD) Fan for carbon fibre oxidation ovens.

Questions buyers ask

What does the exhaust fan on a carbon fibre oxidation oven handle?

Hot process air at about 230 to 300°C carrying hydrogen cyanide, ammonia, CO, water vapour and tarry oligomers from the stabilisation of PAN fibre. It is mostly air, not combustion gas, but it is toxic and fouling, so the fan must be gas-tight and kept hot.

Why is a stainless steel fan used on oxidation oven exhaust?

Condensate from the exhaust contains ammonia, cyanide compounds and organic acids that attack mild steel, and stainless surfaces are easier to clean of tar. Stainless steel also keeps its strength at exhaust temperatures and during exotherm upsets.

How do you stop tar fouling in a carbon fibre oven exhaust fan?

Keep the gas above the tar dew point all the way to the oxidiser by insulating and, where needed, trace heating the duct and fan casing. Provide cleaning doors and plan regular cleaning, because some deposition is unavoidable over a long campaign.

Information needed to quote an ID fan for carbon fibre oxidation ovens

  1. Duty point. Gas volume in m³/h or Am³/h at the fan inlet and the static pressure the fan must develop, with the margin you want on each.
  2. Gas condition. Normal and maximum gas temperature at the fan, dust loading after the collector, moisture and any acid gases such as SO₂ or HCl.
  3. System. Boiler or furnace capacity and fuel, collector type and its pressure drop, and the existing fan curve or nameplate if this is a replacement.
  4. Mechanical. Drive arrangement, flow control (damper, inlet vanes or variable speed drive), rotation and discharge orientation, and a layout drawing or site photograph.
  5. Exhaust composition. Expected HCN, ammonia and CO concentrations and the design bleed rate per zone.
  6. Oxidiser arrangement. Whether the fan pushes into the thermal oxidiser or pulls after it.

Built and tested in Chennai

Adroit Fantech Engineers has designed and manufactured industrial fans at Ayanambakkam, Chennai since 2004. Each impeller, casing and shaft is built for the gas and temperature it will see, performance tested as per IS 4894 or BS 848 Part I, and balanced to grade G 6.3 or G 2.5 as per ISO 21940-11, with the records supplied with the fan. We also replace rotors and retrofit existing fans of any make.

ID Fan for related applications

Industries

Services on this fan

ID Fan for carbon fibre oxidation ovens: send us your duty point

Flow, pressure, gas temperature and the fuel are enough to start a selection.

Get a quote