Forced Draft (FD) Fan · designed and built in Chennai

Forced Draft (FD) Fan for Tube and Pipe Annealing Furnaces

The FD fan on a tube annealing furnace is the combustion air fan feeding the radiant tube or open burners. On a radiant tube furnace it supplies many small burners from one main, often in pulse firing mode. The design point is not just the full load duty but steady pressure while dozens of burners switch on and off.

Send your duty pointCall +91 91766 67102
Ambient, 25 to 45°CAir temperature at the fan
1.13 kg/m³Air density at 40°C
Backward curvedBlade form

How tube and pipe annealing furnaces work

Tube and pipe annealing furnaces are long roller hearth, walking beam or car bottom furnaces that take tubes up to 12 m or more. Carbon steel tubes are normalised or stress relieved at about 600 to 950°C; stainless tubes are solution annealed at 1,050 to 1,100°C and quenched. Where the tubes must stay bright or lightly oxidised, the furnace is heated by gas-fired radiant tubes and filled with a protective atmosphere; where scale is acceptable, open-fired burners are used. Radiant tube burners, often with their own recuperators, discharge into an exhaust manifold along the furnace, and an exhaust (ID) fan pulls the products of combustion from all the tubes to the stack, usually with dilution air to bring the temperature down.

Where the FD fan sits

  1. Inlet filter and silencer
  2. FD fan
  3. Combustion air main
  4. Zone air valves
  5. Radiant tube burners

The fan usually stands at floor level beside the furnace and feeds an air main running its full length, with branches to each zone and each burner. Where the radiant tubes have their own recuperators, the fan delivers cold air and each burner heats its own air; with a central recuperator the fan pushes air through it first. Typical fan pressures are 300 to 700 mmWC.

Air at the FD fan

Air temperature at the fanAmbient, 25 to 45°C
Air after the recuperators350 to 550°C at the burner, downstream of the fan
DustClean filtered air
Pressure at the fan outletTypically 300 to 700 mmWC
Load patternPulse firing switches burners every few seconds; average load follows the mill schedule
Density at the design temperatureAbout 1.13 kg/m³ at 40°C, 94% of standard air. Pressure developed and power drawn scale with density, so the fan is selected at this condition and the motor is checked at the coldest operating or start-up condition.

FD Fan selection for tube and pipe annealing furnaces

Blade formBackward curved, with a steep pressure curve near the duty point
Material of constructionMild steel
Drive and arrangementDirect coupled at two-pole speed on high pressure duties
Bearings and coolingStandard bearings, no cooling
Flow controlVariable speed drive on air main pressure
Also specifiedInlet silencer, acoustic lagging, and a standby fan for continuous lines

What this FD fan has to cope with

Main pressure ripple

When many burners open together in pulse firing, main pressure dips and the last burner on the main can fail to light. A fan with a steep curve, a generously sized main and a drive that holds pressure without hunting solve this.

Noise in the finishing bay

High pressure combustion air fans running at two-pole speed are loud at the inlet, with a strong blade-pass tone. Tube finishing, ultrasonic testing and inspection bays are often next to the furnace, so an inlet silencer, casing lagging and a flexible connection to the air main are part of the duty, not extras.

Air main condensation

Where the plant uses a central recuperator, the long hot air main cools during holiday shutdowns, and moist air trapped in it can condense and collect at low points with scale from the duct. Drains at low points, and a purge with the fan running before relighting, keep water and debris away from the burners.

Energy and control

With burners cycling, the average air demand on a radiant tube furnace is often far below the fan rating. A drive holding constant main pressure follows that average and saves power during holding periods. Keeping air ratio correct at each burner matters more than fan power: excess air through a radiant tube cools it and cuts heat transfer to the tubes.

ID fan and FD fan in tube and pipe annealing furnaces

ID fanFD fan
PositionEnd of the radiant tube exhaust manifoldFeeding the combustion air main
What it handlesRadiant tube exhaust with dilution airAmbient filtered air
Temperature at the fan250 to 400°CAmbient
Main design concernEven suction at every tubeSteady pressure during pulse firing
ControlManifold suctionAir main pressure

See also the Induced Draft (ID) Fan for tube and pipe annealing furnaces.

Questions buyers ask

How much pressure does a radiant tube burner need?

It depends on the burner design. Typical recuperative radiant tube burners need about 200 to 500 mmWC of air at the burner. The combustion air fan adds the losses of the main and valves, so fans of 300 to 700 mmWC are common.

Is the FD fan on an annealing furnace the same as the combustion blower?

Yes. On tube annealing furnaces the forced draft fan is the combustion air blower. It supplies air to the burners and nothing else; the protective atmosphere comes from its own generator or gas supply, and the cooling sections and roller hearth fans are separate units with their own duty.

Should the combustion air fan have a standby?

On a continuous tube annealing line, losing combustion air stops production, leaves tubes part-annealed inside the furnace and can overheat recuperators. A standby fan with automatic changeover is common. On batch or car bottom furnaces a single fan is usually accepted, with a spare impeller or motor in stores.

Information needed to quote an FD fan for tube and pipe annealing furnaces

  1. Duty point. Combustion air quantity in m³/h or kg/h and the static pressure at the fan outlet, with the margins you want.
  2. Air condition. Site ambient temperature range and altitude, and whether the fan takes ambient air or air already heated.
  3. System. Boiler or furnace capacity and fuel, resistance of the air heater, windbox, grate or burner, and the existing fan curve or nameplate if this is a replacement.
  4. Mechanical. Drive arrangement, flow control (damper, inlet vanes or variable speed drive), noise limit, rotation and discharge orientation.
  5. Burner list. Number of burners per zone, burner type and air pressure required at the burner.
  6. Firing mode. Whether burners are modulated or pulse fired, and the switching frequency.

Built and tested in Chennai

Adroit Fantech Engineers has designed and manufactured industrial fans at Ayanambakkam, Chennai since 2004. Each impeller, casing and shaft is built for the gas and temperature it will see, performance tested as per IS 4894 or BS 848 Part I, and balanced to grade G 6.3 or G 2.5 as per ISO 21940-11, with the records supplied with the fan. We also replace rotors and retrofit existing fans of any make.

FD Fan for related applications

Industries

Services on this fan

FD Fan for tube and pipe annealing furnaces: send us your duty point

Flow, pressure, air temperature and the fuel are enough to start a selection.