Forced Draft (FD) Fan for Bell Annealing Furnaces

The FD fan on a gas-fired bell annealing furnace is the combustion air fan mounted on the heating bell. It blows ambient air through the bell recuperator to the burners. Like the exhaust fan, it travels with the bell, so compact, robust construction and reliable reconnection matter as much as the air duty.

Send your duty pointCall +91 91766 67102
Ambient, often warm near the bells, 35 to 50°CAir temperature at the fan
1.09 kg/m³Air density at 50°C
Backward curvedBlade form

How bell annealing furnaces work

Bell annealing furnaces anneal stacks of cold rolled steel coils under a protective atmosphere, usually hydrogen or a hydrogen-nitrogen mix. The coils sit on a base with a powerful convection fan in it, under a sealed inner cover filled with the atmosphere. A heating bell, fired by gas burners or heated electrically, is lowered by crane over the inner cover and heats it, bringing the coils to about 650 to 720°C over many hours. The burner flue gas is drawn off the heating bell, often through a recuperator mounted on the bell that preheats the combustion air. After soaking, the heating bell is moved to another base and a cooling bell with fans, or water spray, cools the inner cover.

Where the FD fan sits

  1. Inlet
  2. Combustion air (FD) fan on bell
  3. Bell recuperator
  4. Air ring main
  5. Burners

The fan is mounted on the heating bell and delivers air through the recuperator to a ring main feeding the burners around the bell. Air pressure needed at the fan is typically 300 to 600 mmWC, covering the recuperator, ring main and burners. The fan works in the warm air around the bells and is disconnected and reconnected each time the bell moves to a new base.

Air at the FD fan

Air temperature at the fanAmbient, often warm near the bells, 35 to 50°C
Air after the recuperator250 to 450°C, downstream of the fan
DustShop dust
Pressure at the fan outletTypically 300 to 600 mmWC
MountingOn a crane-moved bell
Density at the design temperatureAbout 1.09 kg/m³ at 50°C, 91% of standard air. Pressure developed and power drawn scale with density, so the fan is selected at this condition and the motor is checked at the coldest operating or start-up condition.

FD Fan selection for bell annealing furnaces

Blade formBackward curved, compact
Material of constructionMild steel
Drive and arrangementDirect coupled, overhung, on a rigid frame
Bearings and coolingBearings rated for shock loads
Flow controlVariable speed or damper on air pressure
Also specifiedInlet filter and plug-in electrical connection

What this FD fan has to cope with

Shock loads

Bell handling shocks are transmitted straight into the fan bearings at every landing. Bearings with suitable clearance, a rigid frame tied into the bell structure and a balance check after any heavy landing prevent early bearing failure on fans that move several times a week.

Hot ambient

Air around the bells is warm, often 35 to 50°C, so it is lighter than standard air and a fan selected at 20°C delivers less mass flow and pressure than expected. Selecting at the actual inlet temperature, or ducting cooler air to the inlet, avoids a shortfall at full firing.

Uneven burner air

Burners around the bell are fed from a ring main. If the fan has little pressure margin, burners furthest from the fan run short of air and the bell heats unevenly, which affects coil properties. A correctly sized ring main and enough fan pressure keep all burners supplied.

Energy and control

Bell annealing cycles are long, with full firing at heat-up and low firing through the soak. A variable speed combustion air fan saves power during soak compared with a throttling damper. Correct air to fuel ratio, held through the whole cycle, saves the most fuel and keeps the bell recuperator clean.

ID fan and FD fan in bell annealing furnaces

ID fanFD fan
PositionOn the bell, after the recuperatorOn the bell, before the recuperator
What it handlesBurner flue gasAmbient air
Temperature at the fan250 to 350°CAmbient, warm
Main design concernShock loads and hot gasShock loads and even burner air
ControlBell suctionAir pressure

See also the Induced Draft (ID) Fan for bell annealing furnaces.

Questions buyers ask

What is the combustion air fan on a bell annealing furnace?

It is the forced draft fan mounted on the heating bell of a bell annealing furnace. It takes ambient air, pushes it through the bell recuperator and supplies it to the burners around the bell. It is separate from the base convection fan and from the fans on the cooling bell.

Does the bell furnace FD fan move with the bell?

In most designs, yes. The combustion air fan is mounted on the heating bell and travels with it from base to base, with a plug-in electrical connection. This keeps the air path short, but it means the fan must be compact and withstand crane handling shocks without losing balance.

What pressure does a bell annealing combustion air fan need?

The combustion air fan on a bell annealing furnace typically delivers 300 to 600 mmWC, covering the bell recuperator, ring main and burner pressure. The exact figure comes from the burner data and the recuperator air side pressure drop at full firing. Fan selection should use the warm air temperature around the bells.

Information needed to quote an FD fan for bell annealing furnaces

  1. Duty point. Combustion air quantity in m³/h or kg/h and the static pressure at the fan outlet, with the margins you want.
  2. Air condition. Site ambient temperature range and altitude, and whether the fan takes ambient air or air already heated.
  3. System. Boiler or furnace capacity and fuel, resistance of the air heater, windbox, grate or burner, and the existing fan curve or nameplate if this is a replacement.
  4. Mechanical. Drive arrangement, flow control (damper, inlet vanes or variable speed drive), noise limit, rotation and discharge orientation.
  5. Burners. Number of burners on the bell, firing rate and air pressure needed at each burner.
  6. Mounting and handling. Space on the bell, air temperature near the bells and the crane handling arrangement.

Built and tested in Chennai

Adroit Fantech Engineers has designed and manufactured industrial fans at Ayanambakkam, Chennai since 2004. Each impeller, casing and shaft is built for the gas and temperature it will see, performance tested as per IS 4894 or BS 848 Part I, and balanced to grade G 6.3 or G 2.5 as per ISO 21940-11, with the records supplied with the fan. We also replace rotors and retrofit existing fans of any make.

FD Fan for related applications

Industries

Services on this fan

FD Fan for bell annealing furnaces: send us your duty point

Flow, pressure, air temperature and the fuel are enough to start a selection.

Get a quote