Forced Draft (FD) Fan for Tobacco Redrying Plants

The FD fan on a tobacco redrying plant is the zone circulation fan, which pushes air through the steam coils and up through the leaf on the apron. It handles recirculated warm air at zone temperature, not ambient air, and its job is to give even air flow across the bed so that every leaf dries alike.

Send your duty pointCall +91 91766 67102
50 to 90°C, recirculated zone airAir temperature at the fan
1.00 kg/m³Air density at 80°C
Backward curved or backward inclinedBlade form

How tobacco redrying plants work

In a green leaf threshing and redrying plant, cured tobacco is conditioned with steam and water, threshed to separate lamina from stem, and then redried to a uniform moisture for storage and ageing. Lamina and stems pass on separate lines through apron redryers: long, multi-zone conveyor dryers in which zone fans blow heated air up through the bed. The drying zones run at about 60 to 100°C, heated by steam coils from the plant boiler. Cooling zones then bring the leaf down with ambient air, and a reordering zone adds steam and water spray to bring it back to about 11 to 13% moisture before packing. Each zone has its circulation fan, and exhaust fans remove the moist air from the drying and reordering zones.

Where the FD fan sits

  1. Zone return air
  2. Fresh air make-up damper
  3. FD (circulation) fan
  4. Steam coils
  5. Plenum under apron
  6. Leaf bed

Each drying zone has its own fan, mounted beside or above the zone, which draws air from above the bed, mixes in fresh make-up air, and pushes it through the steam coils into the plenum beneath the perforated apron. Most of the air is recirculated; the exhaust fan removes only part of it. The fan pressure covers the coils, the plenum, the apron and the leaf bed, typically 80 to 200 mmWC.

Air at the FD fan

Air temperature at the fan50 to 90°C, recirculated zone air
Air after the coils60 to 100°C, downstream of the fan
DustTobacco dust and fibre carried in the recirculated air
HumidityHigh; set by the exhaust rate of the zone
Cooling zonesSeparate fans on ambient air
Density at the design temperatureAbout 1.00 kg/m³ at 80°C, 83% of standard air. Pressure developed and power drawn scale with density, so the fan is selected at this condition and the motor is checked at the coldest operating or start-up condition.

FD Fan selection for tobacco redrying plants

Blade formBackward curved or backward inclined, for a flat flow across the bed
Material of constructionMild steel with heat-resistant coating; galvanised or stainless in humid zones
Drive and arrangementBelt driven or direct coupled with a variable speed drive
Bearings and coolingBearings outside the warm air stream, with high temperature grease
Flow controlVariable speed drive per zone
Also specifiedInspection door and access to the coil face for cleaning

What this FD fan has to cope with

Coil fouling reduces flow

Tobacco dust and fibre load the face of the steam coils, raising resistance so that a fixed-speed fan delivers less air and the zone dries less. Coil cleaning schedules and a speed-controlled fan that can hold the air flow keep drying even.

Uneven drying across the apron

Poor inlet conditions or a fan oversized and throttled can give uneven air distribution in the plenum, with wet and dry streaks in the lamina. Good plenum design and a fan selected near its best efficiency point give uniform flow.

Warm air on the bearings

The fan handles air at up to 90°C, so bearings close to the casing run warm and grease degrades. Bearings mounted clear of the casing, with a shaft guard and suitable grease, last the season.

Energy and control

Circulation fans run all the time the redryer runs, and a large line may have twenty or more of them, so they make up most of the redryer's electrical load. High efficiency wheels and variable speed drives, set by zone, pay back quickly over a long season. Running each zone only as hard as the leaf needs also saves steam.

ID fan and FD fan in tobacco redrying plants

ID fanFD fan
PositionOn the zone exhaust hoodsBeside each zone, before the steam coils
What it handlesHumid air with tobacco dustRecirculated warm zone air
Temperature at the fan50 to 80°C50 to 90°C
Main design concernDeposits, condensation and fire riskEven flow through the leaf bed
ControlZone humidityZone air flow

See also the Induced Draft (ID) Fan for tobacco redrying plants.

Questions buyers ask

Is the zone fan in a tobacco redryer an FD fan?

In practice it does the job of a forced draft fan for each zone: it pushes air through the heaters and the leaf bed. Unlike a boiler FD fan, it handles mostly recirculated warm air, at 50 to 90°C, rather than ambient air.

What pressure does a redryer zone fan need?

Usually 80 to 200 mmWC, to overcome the steam coils, the plenum, the perforated apron and the leaf bed. The value depends on bed depth and coil design, and allowance must be made for coil fouling.

Why do redryer zone fans need speed control?

Different zones need different air flows, and coil fouling and bed depth change during the season. A variable speed drive on each zone fan lets the operator set the flow for each zone without throttling.

Information needed to quote an FD fan for tobacco redrying plants

  1. Duty point. Combustion air quantity in m³/h or kg/h and the static pressure at the fan outlet, with the margins you want.
  2. Air condition. Site ambient temperature range and altitude, and whether the fan takes ambient air or air already heated.
  3. System. Boiler or furnace capacity and fuel, resistance of the air heater, windbox, grate or burner, and the existing fan curve or nameplate if this is a replacement.
  4. Mechanical. Drive arrangement, flow control (damper, inlet vanes or variable speed drive), noise limit, rotation and discharge orientation.
  5. Zone data. Zone air flow, temperature and the bed depth on the apron.
  6. Heater. Steam coil pressure drop clean and fouled.

Built and tested in Chennai

Adroit Fantech Engineers has designed and manufactured industrial fans at Ayanambakkam, Chennai since 2004. Each impeller, casing and shaft is built for the gas and temperature it will see, performance tested as per IS 4894 or BS 848 Part I, and balanced to grade G 6.3 or G 2.5 as per ISO 21940-11, with the records supplied with the fan. We also replace rotors and retrofit existing fans of any make.

FD Fan for related applications

Industries

Services on this fan

FD Fan for tobacco redrying plants: send us your duty point

Flow, pressure, air temperature and the fuel are enough to start a selection.

Get a quote