Forced Draft (FD) Fan for Supplementary Fired HRSGs

The FD fan on a supplementary fired HRSG is the fresh air fan. When the gas turbine is down, it supplies ambient combustion air to the duct burner so the HRSG keeps steaming as a fired boiler. It also supplies cooling air to the burner elements. It handles clean air, but it must take over within seconds when the turbine trips.

Send your duty pointCall +91 91766 67102
Ambient, 25 to 45°CAir temperature at the fan
1.13 kg/m³Air density at 40°C
Backward curvedBlade form

How supplementary fired hRSGs work

A supplementary fired HRSG adds a duct burner between the gas turbine exhaust and the heat transfer surfaces. Turbine exhaust still holds 13 to 15% oxygen, so the burner fires natural gas or liquid fuel into it without extra air, raising the gas to about 700 to 900°C and the steam output well above that of an unfired unit. Many process plants also need steam when the turbine is down. For that, a fresh air fan supplies ambient air to the burner and the HRSG runs as a conventional fired boiler, known as fresh air firing. In normal operation the turbine pushes the gas through the HRSG within its back pressure limit; during fresh air firing the fresh air fan does that job and the boiler is pressurised.

Where the FD fan sits

  1. Inlet filter and silencer
  2. FD (fresh air) fan
  3. Fresh air damper
  4. Turbine exhaust duct
  5. Duct burner
  6. HRSG

The fresh air fan sits beside the transition duct between the turbine and the HRSG, discharging through an isolating damper into the duct upstream of the duct burner. In turbine mode the damper is shut and the fan is either stopped, or running at low speed to supply burner cooling air. When the turbine trips, the damper opens and the fan provides the full combustion air for the burner, against the resistance of the burner grid and the whole HRSG.

Air at the FD fan

Air temperature at the fanAmbient, 25 to 45°C
Pressure at the fan outletBurner grid plus full HRSG gas-side resistance in fresh air mode
DustFiltered air
Changeover timeMust reach duty quickly after a turbine trip so the burner can stay lit or relight
IsolationDamper must seal against hot turbine exhaust in normal operation
Density at the design temperatureAbout 1.13 kg/m³ at 40°C, 94% of standard air. Pressure developed and power drawn scale with density, so the fan is selected at this condition and the motor is checked at the coldest operating or start-up condition.

FD Fan selection for supplementary fired hRSGs

Blade formBackward curved, for stable flow across the burner turndown
Material of constructionMild steel; heat shield on the discharge side near the hot duct
Drive and arrangementDirect coupled, with a motor and starter able to accelerate fast to duty
Bearings and coolingStandard pedestal bearings; no cooling needed for the fan, but the discharge damper must be tight against hot backflow
Flow controlVariable speed drive or inlet vanes, linked to burner firing rate in fresh air mode
Also specifiedInlet filter and silencer, tight isolation damper, and burner cooling air connection

What this FD fan has to cope with

Hot gas backflow into the fan

In turbine mode the fan discharge sees turbine exhaust at 450 to 600°C behind the isolating damper. If the damper leaks and the fan is stopped, hot gas flows back into the fan and can distort the impeller. A tight damper, a seal air or cooling air bleed, and running the fan at low speed prevent it.

Fast takeover on a turbine trip

Steam users in refineries and chemical plants cannot wait for a slow restart. The fan, damper and burner must reach fresh air firing in a short, defined sequence. The fan motor, starting method and acceleration time are selected so that the air arrives within the time the burner management system allows.

Wide range of air demand

In fresh air mode the burner may fire from low to full rate, and the air must follow. A fan selected for full fresh air firing operates far down its curve at low fire. Speed control, or inlet vanes, keeps the fan stable and the air-fuel ratio correct across the range.

Energy and control

The fresh air fan may run for only a few hundred hours a year, during turbine outages and trips, but at that time it carries the whole steam supply. Its efficiency matters less than its readiness. Where it runs continuously at low speed to provide burner cooling air and keep the damper cool, a variable speed drive keeps that standby power small.

ID fan and FD fan in supplementary fired hRSGs

ID fanFD fan
PositionAfter the economiser, before the stack, only where neededBeside the turbine transition duct, ahead of the duct burner
What it handlesClean exhaust and combustion gasFiltered ambient air
Temperature at the fan120 to 180°CAmbient
Main design concernTwo operating modes and turbine back pressureFast takeover and hot gas backflow
ControlTurbine exhaust or furnace pressure by modeBurner firing rate in fresh air mode

See also the Induced Draft (ID) Fan for supplementary fired hRSGs.

Questions buyers ask

What is fresh air firing on an HRSG?

Fresh air firing lets an HRSG with a duct burner raise steam when the gas turbine is not running. A fresh air fan supplies ambient air to the burner in place of the turbine exhaust, and the HRSG works as a conventional fired boiler. It keeps process steam available during turbine outages.

Does a supplementary fired HRSG always need a fresh air fan?

No. If the plant can do without HRSG steam when the turbine is down, or has auxiliary boilers, the duct burner simply uses turbine exhaust oxygen and no fresh air fan is fitted. The fan is added where steam must continue through turbine trips and outages.

How fast must the fresh air fan start after a turbine trip?

Fast enough for the burner management system to keep or re-establish the flame within its allowed sequence, often within tens of seconds. The fan, motor, starter and damper are selected and tested together to meet the time set by the HRSG and burner supplier. The changeover is proven at commissioning.

Information needed to quote an FD fan for supplementary fired hRSGs

  1. Duty point. Combustion air quantity in m³/h or kg/h and the static pressure at the fan outlet, with the margins you want.
  2. Air condition. Site ambient temperature range and altitude, and whether the fan takes ambient air or air already heated.
  3. System. Boiler or furnace capacity and fuel, resistance of the air heater, windbox, grate or burner, and the existing fan curve or nameplate if this is a replacement.
  4. Mechanical. Drive arrangement, flow control (damper, inlet vanes or variable speed drive), noise limit, rotation and discharge orientation.
  5. Fresh air mode. Maximum firing rate in fresh air mode and the air flow and pressure the burner needs.
  6. Changeover. Required time from turbine trip to full fresh air flow, and whether the fan runs on standby.

Built and tested in Chennai

Adroit Fantech Engineers has designed and manufactured industrial fans at Ayanambakkam, Chennai since 2004. Each impeller, casing and shaft is built for the gas and temperature it will see, performance tested as per IS 4894 or BS 848 Part I, and balanced to grade G 6.3 or G 2.5 as per ISO 21940-11, with the records supplied with the fan. We also replace rotors and retrofit existing fans of any make.

FD Fan for related applications

Industries

Services on this fan

FD Fan for supplementary fired hRSGs: send us your duty point

Flow, pressure, air temperature and the fuel are enough to start a selection.

Get a quote