13, Galaxy Road, Ponniamman Nagar, Ayanambakkam, Chennai 600 095 +91 91766 67102  |  +91 91766 67103  |  marketing@adroitfantech.com
Home › Applications › FD Fan › Carbon Black Tail Gas Fired Boilers

Forced Draft (FD) Fan · designed and built in Chennai

Forced Draft (FD) Fan for Carbon Black Tail Gas Fired Boilers

The FD fan on a carbon black tail gas boiler is the combustion air fan. It supplies ambient air to the tail gas and support fuel burners, and its selection is about holding a stable flame on a lean, variable fuel over a wide range of tail gas flow.

Send your duty pointCall +91 91766 67102
Ambient, 25 to 45°CAir temperature at the fan
1.13 kg/m³Air density at 40°C
Backward curved for efficiency on clean airBlade form

How carbon black tail gas fired boilers work

Carbon black is made by partial combustion of a heavy aromatic feedstock oil in a refractory reactor. After quenching and filtering out the black, the remaining tail gas is a lean fuel: mainly nitrogen and water vapour, with hydrogen and carbon monoxide, a calorific value of typically 500 to 900 kcal/Nm³, and sulphur compounds such as H₂S, COS and CS₂ from the feedstock. The tail gas is burned in a boiler with dedicated burners, usually with a support fuel. Because the fuel is so lean, the flue gas volume per tonne of steam is roughly twice that of an oil-fired boiler, and its moisture content is very high. An FD fan supplies combustion air and an ID fan draws the gas through the boiler and economiser to the stack.

Where the FD fan sits

  1. Inlet screen
  2. FD fan
  3. Air preheater where fitted
  4. Windbox
  5. Tail gas and support fuel burners
  6. Furnace

The fan sits at grade beside the boiler and delivers ambient air to the burner windbox, sometimes through an air preheater that raises the air temperature to help the lean tail gas burn. Air dampers at each burner split the air between tail gas and support fuel firing. The fan must supply the windbox pressure the burners need, typically 150 to 300 mmWC, both when tail gas is plentiful and when the boiler fires support fuel alone during reactor outages.

Air at the FD fan

Air temperature at the fanAmbient, 25 to 45°C
Air after the preheaterUp to about 200°C where an air preheater is fitted, downstream of the fan
DustCarbon black dust in the plant atmosphere; inlet screen or filter needed
Pressure at the fan outletTypically 150 to 300 mmWC
TurndownWide; from low tail gas flow to full flow plus support fuel
Density at the design temperatureAbout 1.13 kg/m³ at 40°C, 94% of standard air. Pressure developed and power drawn scale with density, so the fan is selected at this condition and the motor is checked at the coldest operating or start-up condition.

FD Fan selection for carbon black tail gas fired boilers

Blade formBackward curved for efficiency on clean air
Material of constructionMild steel
Drive and arrangementDirect coupled
Bearings and coolingStandard bearings, no cooling needed
Flow controlVariable speed drive on combustion control, with burner air dampers
Also specifiedInlet filter against carbon black dust, inlet silencer

What this FD fan has to cope with

Flame stability on lean fuel

Tail gas burns slowly and close to its flammability limit. If the air is excessive or poorly distributed, the flame lifts or goes out. A fan with steady pressure and fine flow control lets the combustion system keep excess air low.

Carbon black drawn into the fan

Carbon black plants have fine black dust in the air. It coats the impeller and enters the air preheater. An inlet filter and an intake located away from the packing area keep the fan clean.

Two firing modes

The fan must suit tail gas firing, which needs a large air flow at moderate pressure, and support fuel firing alone. The duty is checked at both points so the fan is not in an unstable part of its curve in either mode.

Energy and control

Combustion air demand follows tail gas availability, which changes with grade and reactor status. A variable speed drive on the combustion control loop replaces damper throttling and saves power for most of the year. Oxygen trim matters more on lean tail gas than on rich fuels because every extra percent of air adds to an already large flue gas volume.

ID fan and FD fan in carbon black tail gas fired boilers

ID fanFD fan
PositionAfter the economiser, before the stackAt the windbox, ahead of the burners
What it handlesWet flue gas with SO₂ and traces of carbonAmbient air
Temperature at the fan180 to 220°CAmbient
Main design concernLarge wet gas volume and acid dew pointStable flame on lean tail gas
ControlFurnace draftCombustion control and oxygen trim

See also the Induced Draft (ID) Fan for carbon black tail gas fired boilers.

Questions buyers ask

Is the FD fan on a tail gas boiler the combustion air fan?

Yes. On a carbon black tail gas boiler the forced draft fan supplies all the combustion air to the tail gas and support fuel burners. It handles ambient air only. The tail gas itself is delivered by the process, so the FD fan duty is the air needed for the lean gas plus the support fuel, at the windbox pressure the burners need.

Does the FD fan supply the tail gas itself?

No. The tail gas comes from the carbon black process, pushed by the process blowers or a dedicated tail gas booster blower. The FD fan supplies only air. Keeping the two separate means the combustion air fan can be a simple clean-air machine, while the tail gas booster, where fitted, is built for a wet, flammable and sulphur-bearing gas.

Why is excess air so important on a carbon black tail gas boiler?

The tail gas is lean and wet. Too little air and the CO and hydrogen do not burn out; too much and the flame becomes unstable and the flue gas volume, and ID fan load, rise sharply.

Information needed to quote an FD fan for carbon black tail gas fired boilers

  1. Duty point. Combustion air quantity in m³/h or kg/h and the static pressure at the fan outlet, with the margins you want.
  2. Air condition. Site ambient temperature range and altitude, and whether the fan takes ambient air or air already heated.
  3. System. Boiler or furnace capacity and fuel, resistance of the air heater, windbox, grate or burner, and the existing fan curve or nameplate if this is a replacement.
  4. Mechanical. Drive arrangement, flow control (damper, inlet vanes or variable speed drive), noise limit, rotation and discharge orientation.
  5. Burner data. Burner type and windbox pressure for tail gas and support fuel firing.
  6. Plant atmosphere. Location of the air intake and the level of carbon black dust nearby.

Built and tested in Chennai

Adroit Fantech Engineers has designed and manufactured industrial fans at Ayanambakkam, Chennai since 2004. Each impeller, casing and shaft is built for the gas and temperature it will see, performance tested as per IS 4894 or BS 848 Part I, and balanced to grade G 6.3 or G 2.5 as per ISO 21940-11, with the records supplied with the fan. We also replace rotors and retrofit existing fans of any make.

FD Fan for related applications

Industries

Services on this fan

FD Fan for carbon black tail gas fired boilers: send us your duty point

Flow, pressure, air temperature and the fuel are enough to start a selection.

Get a quote