13, Galaxy Road, Ponniamman Nagar, Ayanambakkam, Chennai 600 095 +91 91766 67102  |  +91 91766 67103  |  marketing@adroitfantech.com
Home › Applications › FD Fan › Groundnut and Peanut Roasters

Forced Draft (FD) Fan · designed and built in Chennai

Forced Draft (FD) Fan for Groundnut and Peanut Roasters

The FD fan on a groundnut or peanut roaster is the combustion air fan of the burner, or of the hot air generator that supplies the roasting air. It handles clean ambient air and must hold a steady air-fuel ratio as the burner modulates, because burner output controls kernel temperature and therefore roast colour.

Send your duty pointCall +91 91766 67102
Ambient, 25 to 45°CAir temperature at the fan
1.13 kg/m³Air density at 40°C
Backward curvedBlade form

How groundnut and peanut roasters work

Groundnut kernels are roasted to develop flavour and loosen the red skins, either in batch rotary drums or in continuous hot air roasters with a belt or rotating drum. Hot air at about 160 to 220°C, from a direct gas or diesel burner or an indirect hot air generator, passes through the kernels for roughly 10 to 40 minutes until they reach about 150 to 170°C and lose most of their 5 to 7% moisture. In continuous roasters most of the air is recirculated through the burner box, and a part is bled off as exhaust carrying moisture, oil vapour, loose skins and dust through a cyclone to the exhaust fan. The roasted kernels then pass to a cooler, where ambient air is drawn through the bed, before blanching or packing.

Where the FD fan sits

  1. Inlet filter
  2. FD fan
  3. Air-fuel ratio damper
  4. Burner
  5. Burner box
  6. Roasting chamber

On direct-fired roasters the combustion air fan is mounted on or beside the burner, feeding air through a modulating damper linked to the gas or oil valve. On roasters heated by a separate hot air generator, it sits on the generator and pushes air into the combustion chamber, from which hot gas passes a heat exchanger. The large fan moving roasting air round the loop is a separate recirculation fan, and the cooler has its own fan pulling ambient air through the roasted kernels.

Air at the FD fan

Air temperature at the fanAmbient, 25 to 45°C
DustPeanut dust and skin flakes in the roasting hall; inlet filter needed
Pressure at the fan outletTypically 100 to 300 mmWC at the burner
TurndownBurner modulates through each batch and with throughput changes
Density at the design temperatureAbout 1.13 kg/m³ at 40°C, 94% of standard air. Pressure developed and power drawn scale with density, so the fan is selected at this condition and the motor is checked at the coldest operating or start-up condition.

FD Fan selection for groundnut and peanut roasters

Blade formBackward curved, for a stable curve and quiet running
Material of constructionMild steel, painted
Drive and arrangementDirect mounted on the motor shaft
Bearings and coolingMotor bearings; no cooling needed
Flow controlCharacterised damper or variable speed drive linked to the fuel valve
Also specifiedInlet filter, air pressure switch for burner safety, and a low-noise inlet

What this FD fan has to cope with

Inlet filter clogging with skins

Skin flakes and peanut dust in the hall are drawn onto the inlet filter. As it loads, combustion air falls, and the flame turns rich and sooty, which can taint the roast. A filter sized for low face velocity, an air pressure switch and a fixed filter-changing routine keep the air flow where the burner needs it.

Air-fuel ratio drift at low fire

Roasters spend long periods at low fire between batches or at reduced throughput. A fan with a flat curve, or a damper with slack in its linkage, lets the ratio drift so the burner runs with too much or too little air. A variable speed drive or characterised damper tied to the fuel valve holds it.

Burner trips from low air pressure

A worn impeller, a dirty inlet or a slipping belt on older units reduces air pressure until the burner safety switch trips mid-batch and spoils the roast. A direct-drive fan with pressure margin over the burner requirement, and a filter gauge the operator can read, avoid nuisance trips.

Energy and control

The burner fan is small, but it runs every hour the roaster is hot. The larger energy lever is the excess air it delivers: surplus air is heated and then carried out with the exhaust bleed. Setting the fan, by speed or damper, to the burner maker's air-fuel curve and checking flue oxygen periodically cuts fuel use while keeping the flame clean.

ID fan and FD fan in groundnut and peanut roasters

ID fanFD fan
PositionAfter the skin cyclone, on the exhaust bleedOn the burner or hot air generator
What it handlesHot, moist air with skins and oil vapourClean ambient air
Temperature at the fan130 to 180°CAmbient, 25 to 45°C
Main design concernOily deposits and fireSteady air-fuel ratio
ControlChamber pressure or bleed rateBurner firing rate

See also the Induced Draft (ID) Fan for groundnut and peanut roasters.

Questions buyers ask

What does the FD fan do on a peanut roaster?

It supplies combustion air to the burner, either on the roaster itself or on the hot air generator feeding it. The burner then heats the roasting air that passes through the kernels. The fan handles clean ambient air, so it is a small backward curved unit whose job is a steady air supply as the burner modulates.

Why is the groundnut roaster burner flame sooty?

Usually the burner is short of air. A clogged inlet filter, a slipping belt, a worn impeller or a damper linkage that has moved all reduce combustion air. Restoring fan pressure and resetting the air-fuel ratio with a flue gas analyser clears the soot, which otherwise taints the roasted groundnuts and fouls the burner box.

Can one fan supply both burner air and roasting air?

On small batch roasters a single fan sometimes does both, but larger roasters separate them. The burner needs a modest, controlled flow of combustion air, while roasting air is a much larger recirculated flow. Separate fans let burner firing and air flow be controlled independently, which gives a more even roast.

Information needed to quote an FD fan for groundnut and peanut roasters

  1. Duty point. Combustion air quantity in m³/h or kg/h and the static pressure at the fan outlet, with the margins you want.
  2. Air condition. Site ambient temperature range and altitude, and whether the fan takes ambient air or air already heated.
  3. System. Boiler or furnace capacity and fuel, resistance of the air heater, windbox, grate or burner, and the existing fan curve or nameplate if this is a replacement.
  4. Mechanical. Drive arrangement, flow control (damper, inlet vanes or variable speed drive), noise limit, rotation and discharge orientation.
  5. Burner details. Fuel, burner rating and the air pressure the burner maker requires at full fire.
  6. Firing arrangement. Whether the burner fires direct into the roasting air or into a separate hot air generator.

Built and tested in Chennai

Adroit Fantech Engineers has designed and manufactured industrial fans at Ayanambakkam, Chennai since 2004. Each impeller, casing and shaft is built for the gas and temperature it will see, performance tested as per IS 4894 or BS 848 Part I, and balanced to grade G 6.3 or G 2.5 as per ISO 21940-11, with the records supplied with the fan. We also replace rotors and retrofit existing fans of any make.

FD Fan for related applications

Industries

Services on this fan

FD Fan for groundnut and peanut roasters: send us your duty point

Flow, pressure, air temperature and the fuel are enough to start a selection.

Get a quote