Forced Draft (FD) Fan for Gypsum Flash Dryers

The FD fan on a gypsum flash dryer is the combustion air fan for the hot gas generator. It handles ambient air. Where the hot gas generator also needs dilution air to bring the gas down to the flash duct inlet temperature, the same fan or a separate dilution fan supplies it.

Send your duty pointCall +91 91766 67102
Ambient, 25 to 45°CAir temperature at the fan
1.13 kg/m³Air density at 40°C
Backward curvedBlade form

How gypsum flash dryers work

Natural gypsum, phosphogypsum from phosphoric acid plants or FGD gypsum is dried and often calcined to plaster of Paris in a flash dryer or flash calciner. A hot gas generator burning coal, oil, gas or biomass supplies gas at typically 300 to 600°C. Wet gypsum, often 10 to 25% free moisture for phosphogypsum, is milled or dispersed into the gas, dried in the flash duct and, for calcination, heated further so that the outlet runs at about 140 to 170°C. Drying alone leaves the gas at about 90 to 120°C. The product is collected in cyclones and a bag filter, and the ID fan after the bag filter sends the gas to the stack. Combustion air for the hot gas generator comes from an FD fan.

Where the FD fan sits

  1. Inlet filter
  2. FD (combustion air) fan
  3. Burner or grate
  4. Hot gas generator
  5. Dilution air
  6. Flash duct

The fan sits beside the hot gas generator and supplies air to the burner or under the grate. The hot gas leaves the generator and is mixed with dilution air or recirculated gas to set the flash duct inlet temperature. The fan pressure covers the burner or fuel bed and the generator, typically 100 to 300 mmWC. On recirculating designs, part of the exhaust gas is returned to the mixing chamber instead of fresh dilution air.

Air at the FD fan

Air temperature at the fanAmbient, 25 to 45°C
Air after the fanUnheated
DustGypsum and plaster dust in the plant air; filtered intake needed
HumidityNo significant effect
Pressure at the fan outletTypically 100 to 300 mmWC
Density at the design temperatureAbout 1.13 kg/m³ at 40°C, 94% of standard air. Pressure developed and power drawn scale with density, so the fan is selected at this condition and the motor is checked at the coldest operating or start-up condition.

FD Fan selection for gypsum flash dryers

Blade formBackward curved
Material of constructionMild steel
Drive and arrangementDirect coupled or direct mounted
Bearings and coolingStandard bearings
Flow controlVariable speed drive on burner firing rate
Also specifiedInlet filter against plaster dust

What this FD fan has to cope with

Plaster dust on the fan

Gypsum plants are dusty, and plaster dust drawn into an unfiltered fan intake sets on the blades in humid air. A filtered intake from a clean area avoids this. The intake is placed upwind of the calciner and product handling, and the filter is checked often in dry weather.

Inlet temperature control

Gypsum calcination is sensitive to temperature. Poor combustion air control causes swings in flash duct inlet temperature and uneven product. Speed-controlled combustion and dilution air give steadier temperatures. Precise temperature control also limits overheating, which forms anhydrite and changes the setting time of the plaster.

Fuel changes

Switching between coal, oil and biomass changes the air needed. The fan is sized for the fuel needing the most air at full load. Coal and biomass on a grate also need undergrate and overfire air split, which affects the fan pressure. These are settled with the hot gas generator supplier.

Energy and control

The combustion air fan follows the hot gas generator load. Speed control holds the air-fuel ratio and limits excess air, which reduces both fuel and the gas volume that the ID fan must handle. Using recirculated exhaust gas instead of fresh dilution air further reduces fuel on some designs. Matching the dilution air to the actual flash duct temperature avoids overheating the product.

ID fan and FD fan in gypsum flash dryers

ID fanFD fan
PositionAfter the bag filterAt the hot gas generator
What it handlesHumid gas with fine gypsumAmbient combustion air
Temperature at the fan100 to 160°CAmbient
Main design concernPlaster setting and condensationInlet temperature control
ControlSystem suction or outlet temperatureBurner firing rate

See also the Induced Draft (ID) Fan for gypsum flash dryers.

Questions buyers ask

What does the FD fan do on a gypsum flash dryer?

It supplies combustion air to the hot gas generator, and in some designs dilution air that cools the hot gas to the flash duct inlet temperature. It handles clean ambient air, so it is mild steel and selected at ambient density. The intake is filtered against plaster dust.

Is a separate dilution air fan needed?

Not always. Some hot gas generators take dilution air from the same fan through a split duct; others use a separate fan or recirculated gas for finer temperature control. Recirculated gas saves fuel but adds moisture to the flash duct, which the ID fan and bag filter must then handle at a higher dew point.

Why does flash duct inlet temperature swing?

Often because combustion air and fuel are not well matched. Speed-controlled combustion air, tied to the burner and to the duct temperature, steadies it. Fouling in the hot gas generator, uneven fuel feed and a sticking dilution damper are other common causes worth checking during a site visit.

Information needed to quote an FD fan for gypsum flash dryers

  1. Duty point. Combustion air quantity in m³/h or kg/h and the static pressure at the fan outlet, with the margins you want.
  2. Air condition. Site ambient temperature range and altitude, and whether the fan takes ambient air or air already heated.
  3. System. Boiler or furnace capacity and fuel, resistance of the air heater, windbox, grate or burner, and the existing fan curve or nameplate if this is a replacement.
  4. Mechanical. Drive arrangement, flow control (damper, inlet vanes or variable speed drive), noise limit, rotation and discharge orientation.
  5. Hot gas generator. Fuel, firing rate and air pressure required.
  6. Dilution. Whether dilution air comes from the same fan or from recirculated exhaust.

Built and tested in Chennai

Adroit Fantech Engineers has designed and manufactured industrial fans at Ayanambakkam, Chennai since 2004. Each impeller, casing and shaft is built for the gas and temperature it will see, performance tested as per IS 4894 or BS 848 Part I, and balanced to grade G 6.3 or G 2.5 as per ISO 21940-11, with the records supplied with the fan. We also replace rotors and retrofit existing fans of any make.

FD Fan for related applications

Industries

Services on this fan

FD Fan for gypsum flash dryers: send us your duty point

Flow, pressure, air temperature and the fuel are enough to start a selection.

Get a quote