Forced Draft (FD) Fan · designed and built in Chennai

Forced Draft (FD) Fan for Guar Gum Flash Dryers

The FD fan on a guar gum flash dryer is the hot air supply fan, used on larger lines to push air through the thermic fluid or indirect air heater into the mill. It handles filtered ambient air before the heater. Its job is to share the high system pressure with the exhaust fan.

Send your duty pointCall +91 91766 67102
Ambient, 25 to 45°CAir temperature at the fan
1.13 kg/m³Air density at 40°C
Backward curvedBlade form

How guar gum flash dryers work

Guar splits, the endosperm separated from the husk and germ of the guar seed, are soaked to about 50 to 60% moisture, flaked, and then ground and dried at the same time in a mill-dryer. Hot air at typically 150 to 250°C, usually from a thermic fluid or indirect fired air heater, sweeps through the mill and lifts the ground powder up a flash duct, drying it to about 10 to 12% moisture. Cyclones and a bag filter collect the powder, which is then sieved and blended to the required mesh and viscosity grade. An exhaust fan after the bag filter pulls the air through the mill and collectors, and on larger lines a supply fan pushes air through the heater.

Where the FD fan sits

  1. Air filter
  2. FD (supply air) fan
  3. Thermic fluid air heater
  4. Hot air duct
  5. Mill-dryer inlet

The supply fan sits before the air heater, so it handles cool air and pushes it through the heater and into the mill. On smaller lines without a supply fan, the exhaust fan pulls air through the heater. A supply fan is added when the total system loss is too high for one fan or when the mill inlet must be held close to atmospheric pressure.

Air at the FD fan

Air temperature at the fanAmbient, 25 to 45°C
Air after the heater150 to 250°C, downstream of the fan
DustFiltered air; desert dust in summer loads filters quickly
HumidityLow humidity in dry seasons helps drying
Pressure at the fan outletSet by the heater and mill inlet, typically 150 to 300 mmWC
Density at the design temperatureAbout 1.13 kg/m³ at 40°C, 94% of standard air. Pressure developed and power drawn scale with density, so the fan is selected at this condition and the motor is checked at the coldest operating or start-up condition.

FD Fan selection for guar gum flash dryers

Blade formBackward curved
Material of constructionMild steel with food-grade coating, or stainless steel where specified
Drive and arrangementDirect coupled
Bearings and coolingStandard bearings
Flow controlVariable speed drive on air flow
Also specifiedFilter differential pressure gauge and inspection door

What this FD fan has to cope with

Dust-laden intake air

In dry, dusty regions the air filters load fast, and the supply fan loses flow. Speed control on measured air flow and regular filter changes keep the drying stable. An intake placed away from roads and yards also helps. A filter differential pressure gauge tells the operator when to change them.

Balancing with the exhaust fan

If the supply fan pushes harder than the exhaust fan pulls, powder escapes at the mill seals. The exhaust fan controls mill suction and the supply fan controls air flow. An interlock stops the supply fan if the exhaust fan trips. Both fans on speed control make this simple.

Heater fouling

Dust passing poor filters fouls the heater coils, raising resistance and lowering heat transfer. Good filtration protects both heater and fan duty. A thermic fluid coil that fouls also loses heat output, which forces the heater to run hotter and stresses the fluid. Pressure drop measurement across the coil shows when it needs cleaning.

Energy and control

The supply fan handles all the drying air across long campaigns. An efficient backward curved wheel with speed control is the standard choice. Keeping the filters and heater clean reduces the pressure and power needed. Heat recovery from the exhaust adds a coil pressure drop to the supply fan duty but reduces thermic fluid load across the campaign.

ID fan and FD fan in guar gum flash dryers

ID fanFD fan
PositionAfter the bag filterBefore the air heater
What it handlesHumid air with fine guar powderFiltered ambient air
Temperature at the fan60 to 85°CAmbient
Main design concernGel deposits and high mill suctionFilter loading and pressure balance
ControlMill suctionAir flow

See also the Induced Draft (ID) Fan for guar gum flash dryers.

Questions buyers ask

Does a guar gum dryer always have an FD fan?

No. Many lines use only an exhaust fan, pulling air through the heater and mill. A supply fan is added on larger lines or where the mill needs near-atmospheric inlet pressure. The supply fan is sized with the exhaust fan, so that each covers its share of the system resistance and the mill inlet stays close to atmospheric.

Should the supply fan be before or after the thermic fluid heater?

Before, so it handles cool, dense air and needs no high-temperature construction. The heater is then on the pressure side, and the fan bearings and casing stay at ambient temperature. A filter before the fan keeps desert dust off both the fan and the heater coil.

How is the supply fan controlled?

On drying air flow, with the exhaust fan controlling suction at the mill, both through variable speed drives. The two drives are interlocked so the supply fan cannot run alone, and each grade has its own air flow setting to suit mesh size and viscosity targets.

Information needed to quote an FD fan for guar gum flash dryers

  1. Duty point. Combustion air quantity in m³/h or kg/h and the static pressure at the fan outlet, with the margins you want.
  2. Air condition. Site ambient temperature range and altitude, and whether the fan takes ambient air or air already heated.
  3. System. Boiler or furnace capacity and fuel, resistance of the air heater, windbox, grate or burner, and the existing fan curve or nameplate if this is a replacement.
  4. Mechanical. Drive arrangement, flow control (damper, inlet vanes or variable speed drive), noise limit, rotation and discharge orientation.
  5. Heater. Thermic fluid or indirect heater type and its air-side pressure drop.
  6. Site conditions. Ambient dust and temperature range at the intake.

Built and tested in Chennai

Adroit Fantech Engineers has designed and manufactured industrial fans at Ayanambakkam, Chennai since 2004. Each impeller, casing and shaft is built for the gas and temperature it will see, performance tested as per IS 4894 or BS 848 Part I, and balanced to grade G 6.3 or G 2.5 as per ISO 21940-11, with the records supplied with the fan. We also replace rotors and retrofit existing fans of any make.

FD Fan for related applications

Industries

Services on this fan

FD Fan for guar gum flash dryers: send us your duty point

Flow, pressure, air temperature and the fuel are enough to start a selection.

Get a quote