Forced Draft (FD) Fan for Copper Shaft Melting Furnaces

The FD fan on a copper shaft furnace is the combustion air fan feeding the rows of burners around the base of the shaft. Each burner needs a precise air-gas ratio to keep the atmosphere slightly reducing, so stable air pressure at every burner matters more than anything else in the selection.

Send your duty pointCall +91 91766 67102
Ambient, 25 to 45°CAir temperature at the fan
1.13 kg/m³Air density at 40°C
Backward curvedBlade form

How copper shaft melting furnaces work

A copper shaft furnace melts cathode, and clean scrap or reverts, continuously. Charge is fed at the top of a vertical refractory shaft and descends against hot gas from several rows of natural gas or LPG burners around the base. Each burner is fired slightly fuel rich so that the molten copper does not pick up oxygen, which leaves CO and hydrogen in the gas. Molten copper at about 1,120 to 1,150°C runs to a holding furnace and on to a continuous caster or rod mill. Because the gas gives up its heat to the cold charge, it leaves the top at a modest 250 to 500°C. An afterburner or the charging hood burns the CO with air before the gas goes to a recuperator or stack, often through an ID fan.

Where the FD fan sits

  1. Inlet filter and silencer
  2. FD (combustion air) fan
  3. Recuperator (if fitted)
  4. Air ring main
  5. Burner ratio controls
  6. Burner rows

The fan sits at ground level and supplies a ring main around the shaft, from which each burner takes air through its own ratio control. Where a recuperator is fitted, the fan pushes cold air through it first. The pressure must cover the recuperator, the ring main, the ratio valves and premix or nozzle-mix burners, typically 400 to 800 mmWC.

Air at the FD fan

Air temperature at the fanAmbient, 25 to 45°C
Air after the recuperator200 to 350°C where fitted, downstream of the fan
DustFiltered air
Pressure at the fan outletTypically 400 to 800 mmWC
TurndownMelting rate varies with caster demand; individual burner rows are switched in and out
Density at the design temperatureAbout 1.13 kg/m³ at 40°C, 94% of standard air. Pressure developed and power drawn scale with density, so the fan is selected at this condition and the motor is checked at the coldest operating or start-up condition.

FD Fan selection for copper shaft melting furnaces

Blade formBackward curved, with a steep pressure curve for stable header pressure
Material of constructionMild steel throughout
Drive and arrangementDirect coupled at two-pole speed for the higher pressures
Bearings and coolingStandard bearings; no cooling needed
Flow controlVariable speed drive holding ring main pressure
Also specifiedInlet filter, inlet silencer and often a standby fan, since loss of air stops melting

What this FD fan has to cope with

Ratio drift as burners switch

Shaft furnaces change melting rate by switching burners or whole rows on and off. When a row is switched off, ring main pressure rises and the remaining burners receive more air than their gas valves expect, so they run lean and oxidise the copper. A drive holding constant header pressure keeps each burner's ratio where it was set.

Burner backfire on air loss

Premix burners can flash back into the mixer if air pressure falls while gas is still flowing. Low air pressure switches on the ring main, a gas shut-off interlocked to them, and a fan curve with no unstable region at low flow protect the burners when several rows are turned down together.

Noise at the charging floor

Combustion air fans at 400 to 800 mmWC run at two-pole speed and are loud at the inlet, and the fan is often close to the charging platform where operators work all shift. An inlet silencer, a lagged casing and flexible connections to stop duct-borne noise keep levels acceptable.

Energy and control

The combustion air fan runs as long as the furnace melts, often around the clock. Matching fan speed to the active burner rows, instead of throttling with a damper, saves power during reduced melting and holding. The larger saving usually comes from correct air-fuel ratio, which also governs copper quality, so control stability is worth more than a small gain in fan efficiency.

ID fan and FD fan in copper shaft melting furnaces

ID fanFD fan
PositionAfter the afterburner and recuperatorAt the base, feeding the burner ring main
What it handlesBurned-out shaft gas with little dustClean ambient air
Temperature at the fan250 to 350°C, up to 500°C upsetAmbient
Main design concernCO safety and fine hood controlStable ratio at every burner
ControlCharging hood pressureRing main pressure

See also the Induced Draft (ID) Fan for copper shaft melting furnaces.

Questions buyers ask

What does the FD fan supply on a copper shaft furnace?

It supplies combustion air to the burners around the base of the shaft. On this furnace the FD fan is the combustion air blower, sized for all burner rows firing at full rate plus the losses of any recuperator, the ring main and the ratio valves. It handles only clean ambient air.

Why do shaft furnace burners need such stable air pressure?

The burners run slightly fuel rich to keep oxygen out of the copper. A small change in air pressure shifts the air-gas ratio at every burner, either oxidising the melt or wasting fuel and raising CO. Holding header pressure constant with a speed-controlled fan keeps the ratio steady as burner rows switch.

Is a standby combustion air fan needed on a shaft furnace?

On a furnace that feeds a continuous caster or rod line, many plants fit a standby fan with automatic changeover, because loss of combustion air stops melting within minutes and can freeze metal in the launder and holding furnace. On smaller batch-fed operations a spare impeller and motor may be enough.

Information needed to quote an FD fan for copper shaft melting furnaces

  1. Duty point. Combustion air quantity in m³/h or kg/h and the static pressure at the fan outlet, with the margins you want.
  2. Air condition. Site ambient temperature range and altitude, and whether the fan takes ambient air or air already heated.
  3. System. Boiler or furnace capacity and fuel, resistance of the air heater, windbox, grate or burner, and the existing fan curve or nameplate if this is a replacement.
  4. Mechanical. Drive arrangement, flow control (damper, inlet vanes or variable speed drive), noise limit, rotation and discharge orientation.
  5. Burner arrangement. Number of burner rows and burners, and the air pressure each burner needs.
  6. Ratio control. Type of ratio control and whether air is preheated.

Built and tested in Chennai

Adroit Fantech Engineers has designed and manufactured industrial fans at Ayanambakkam, Chennai since 2004. Each impeller, casing and shaft is built for the gas and temperature it will see, performance tested as per IS 4894 or BS 848 Part I, and balanced to grade G 6.3 or G 2.5 as per ISO 21940-11, with the records supplied with the fan. We also replace rotors and retrofit existing fans of any make.