Forced Draft (FD) Fan · designed and built in Chennai

Forced Draft (FD) Fan for High Pressure Bagasse Cogeneration Boilers

The FD fan on a high pressure bagasse cogeneration boiler supplies undergrate air through a large air heater, usually as two fans in parallel. Like the ID fans it is a major auxiliary load, so its efficiency at the real operating point and its coordination with secondary and distributor air fans matter as much as its capacity.

Send your duty pointCall +91 91766 67102
Ambient, 25 to 45°CAir temperature at the fan
1.13 kg/m³Air density at 40°C
Aerofoil backward curvedBlade form

How high pressure bagasse cogeneration boilers work

High pressure bagasse cogeneration boilers raise steam at about 65 to 110 bar and 485 to 540°C for back-pressure or extraction-condensing turbines that supply the sugar mill and export power to the grid. Units of 80 to 250 TPH, usually on travelling or dumping grates with pneumatic spreaders, are typical. Because exported power is sold, auxiliary power is closely watched and efficiency equipment such as large economisers and air heaters is used, bringing exit gas down to about 140 to 160°C. An ESP cleans the gas before the ID fans. Many plants run through the off-season on stored bagasse, cane trash or other biomass, and some on coal where permitted.

Where the FD fan sits

  1. Inlet silencer
  2. FD fans
  3. Air heater
  4. Undergrate air duct
  5. Grate zones
  6. Furnace

Two FD fans, each sized for about 55 to 60% of full flow, draw ambient air through silencers and push it through a large tubular air heater into the zoned undergrate plenum. Air leaves the air heater at about 220 to 280°C. Secondary air fans supply high-velocity overfire nozzles, and distributor air fans power the pneumatic spreaders, so the FD fans carry only part of the total combustion air.

Air at the FD fan

Air temperature at the fanAmbient, 25 to 45°C
Air after the air heater220 to 280°C, downstream of the fans
Pressure at the fan outletAbout 200 to 300 mmWC
ArrangementTwo fans in parallel, each about 55 to 60%
Duty variationSeason and off-season fuels, varying load
Density at the design temperatureAbout 1.13 kg/m³ at 40°C, 94% of standard air. Pressure developed and power drawn scale with density, so the fan is selected at this condition and the motor is checked at the coldest operating or start-up condition.

FD Fan selection for high pressure bagasse cogeneration boilers

Blade formAerofoil backward curved, for high efficiency on clean air
Material of constructionMild steel
Drive and arrangementDirect coupled with pedestal bearings
Bearings and coolingTemperature and vibration monitoring
Flow controlVariable speed drives with oxygen trim
Also specifiedInlet silencers, isolation dampers, non-return dampers on parallel fans

What this FD fan has to cope with

Auxiliary power

Large FD fans running throttled at part load waste power that could otherwise be exported, and over a long season the loss is substantial. Aerofoil impellers with variable speed drives, selected for the normal operating point, recover most of it. On older plants, re-rating the impeller to the real measured duty is often cost-effective.

Off-season fuels need different air

Off-season biomass or coal needs a different air quantity and a different split between undergrate and secondary air than bagasse does, usually less total air because the fuel is drier. The FD fans must handle both cases without running far from best efficiency. We check both duty points at selection and confirm motor rating at the higher one.

Parallel fan sharing

Two FD fans on a common duct must share flow evenly and avoid stall at low load, and a stopped fan must not let air flow backwards through it. Matched fan curves, coordinated speed control from one controller, and non-return or isolation dampers on each fan make parallel operation and single-fan running stable.

Energy and control

As with the ID fans, FD fan power is judged against exported electricity. Variable speed drives with oxygen trim, efficient aerofoil impellers, low air heater leakage and correct air split between undergrate and secondary air give the lowest consumption. Where loads drop in the off-season, operating a single FD fan near its best point is usually more efficient than two at low output.

ID fan and FD fan in high pressure bagasse cogeneration boilers

ID fanFD fan
PositionAfter ESP, two fans in parallelBefore air heater, two fans in parallel
What it handlesWet flue gas, low dustAmbient air
Temperature at the fan140 to 160°CAmbient, 25 to 45°C
Main design concernEfficiency and reliability for export powerEfficiency and air split
ControlVFDs on furnace draftVFDs with oxygen trim

See also the Induced Draft (ID) Fan for high pressure bagasse cogeneration boilers.

Questions buyers ask

How many FD fans does a 150 TPH bagasse cogeneration boiler need?

Usually two FD fans in parallel, each about 55 to 60% of full flow. This keeps the boiler running at reduced load if one fan is out of service and keeps each fan to a practical size. Exact sizing comes from the boiler air system design.

Why are aerofoil fans used for FD duty on cogeneration boilers?

The FD fans handle clean ambient air, so aerofoil blades can be used without erosion risk. They give the highest efficiency, which matters where every kilowatt saved can be exported, and they have a stable curve suitable for parallel operation. The extra cost over a plain backward curved wheel is usually recovered quickly.

What is the FD fan temperature on a high pressure bagasse boiler?

The fan itself handles ambient air at about 25 to 45°C, because it sits ahead of the air heater. The air is heated to about 220 to 280°C in the air heater downstream of the fan. This keeps the fan smaller, cooler and simpler than one placed in hot air, and lets it work at ambient density.

Information needed to quote an FD fan for high pressure bagasse cogeneration boilers

  1. Duty point. Combustion air quantity in m³/h or kg/h and the static pressure at the fan outlet, with the margins you want.
  2. Air condition. Site ambient temperature range and altitude, and whether the fan takes ambient air or air already heated.
  3. System. Boiler or furnace capacity and fuel, resistance of the air heater, windbox, grate or burner, and the existing fan curve or nameplate if this is a replacement.
  4. Mechanical. Drive arrangement, flow control (damper, inlet vanes or variable speed drive), noise limit, rotation and discharge orientation.
  5. Air split. Shares of undergrate, secondary and distributor air for each fuel.
  6. Redundancy. Required capacity of one fan running alone.

Built and tested in Chennai

Adroit Fantech Engineers has designed and manufactured industrial fans at Ayanambakkam, Chennai since 2004. Each impeller, casing and shaft is built for the gas and temperature it will see, performance tested as per IS 4894 or BS 848 Part I, and balanced to grade G 6.3 or G 2.5 as per ISO 21940-11, with the records supplied with the fan. We also replace rotors and retrofit existing fans of any make.

FD Fan for related applications

Industries

Services on this fan

FD Fan for high pressure bagasse cogeneration boilers: send us your duty point

Flow, pressure, air temperature and the fuel are enough to start a selection.

Get a quote