Forced Draft (FD) Fan · designed and built in Chennai

Forced Draft (FD) Fan for Bagasse Travelling Grate Boilers

The FD fan on a bagasse travelling grate boiler supplies undergrate air through the air heater to the zoned plenums beneath the moving grate. Because most bagasse burns in suspension, it carries only part of the combustion air; its design is set by steady zone pressure across a wide grate and close coordination with the secondary and distributor air fans.

Send your duty pointCall +91 91766 67102
Ambient, 25 to 45°CAir temperature at the fan
1.13 kg/m³Air density at 40°C
Backward curved or aerofoilBlade form

How bagasse travelling grate boilers work

Travelling grate bagasse boilers, typically 40 to 150 TPH, spread bagasse pneumatically across a slowly moving grate that carries ash continuously to the front of the furnace. Most of the fine bagasse burns in suspension; the coarser fibre lands on the grate and burns out as it travels. Continuous ash discharge gives steady furnace conditions without the cycles of a dumping grate. Bagasse at about 50% moisture produces a large, wet flue gas flow, which passes the superheater, boiler bank, economiser and a large air heater before an ESP. Two ID fans in parallel are common, with FD, secondary air and distributor air fans on the air side.

Where the FD fan sits

  1. Inlet screen
  2. FD fan
  3. Air heater
  4. Undergrate duct
  5. Zone dampers
  6. Travelling grate

The FD fan, or two fans in parallel on larger units, pushes ambient air through the tubular air heater into a duct that feeds several compartments under the grate. Each compartment damper sets air along the grate length. A separate secondary air fan supplies overfire nozzles, and a distributor air fan powers the pneumatic bagasse spreaders. Undergrate air is typically 40 to 60% of the total, with the rest above the grate.

Air at the FD fan

Air temperature at the fanAmbient, 25 to 45°C
Air after the air heater200 to 250°C, downstream of the fan
Pressure at the fan outletAbout 150 to 250 mmWC
Share of total airAbout 40 to 60% as undergrate air
DustBagasse pith around the intake
Density at the design temperatureAbout 1.13 kg/m³ at 40°C, 94% of standard air. Pressure developed and power drawn scale with density, so the fan is selected at this condition and the motor is checked at the coldest operating or start-up condition.

FD Fan selection for bagasse travelling grate boilers

Blade formBackward curved or aerofoil, for efficiency on clean air
Material of constructionMild steel
Drive and arrangementDirect coupled with pedestal bearings
Bearings and coolingStandard bearings, vibration monitoring on larger fans
Flow controlVariable speed drive on steam pressure with oxygen trim
Also specifiedInlet screen and silencer; outlet isolation damper where two fans run in parallel

What this FD fan has to cope with

Uneven air across a wide grate

Wide travelling grates need even air along and across their length. If plenum pressure sags at part load, the edge zones and the rear of the grate starve, and bagasse piles there and burns poorly. A fan with a steadily rising pressure curve, controlled to plenum pressure rather than by a single damper, keeps air distribution even.

Air heater erosion and leakage

Sand in the flue gas erodes the inlet ends of air heater tubes, and leaking tubes pass FD air directly to the gas side. FD flow and pressure must include this leakage, which grows over the season, otherwise the grate runs short of air in the last months before the overhaul. The same leakage adds to ID fan load.

Coordination with secondary air

If the FD fan supplies too much of the total air, overfire turbulence weakens and unburnt fibre carries over to the air heater and ESP, where it can catch fire. The FD and secondary air fans are sized and controlled together, so that both the total air and the split between them can be held.

Energy and control

The FD fan on a travelling grate bagasse boiler runs at high load for months. A variable speed drive with oxygen trim keeps excess air low as bagasse moisture changes, which saves power on the FD fan and, more importantly, reduces wet gas volume through the ID fans. Clean inlet screens and tight air heater tubes add further savings.

ID fan and FD fan in bagasse travelling grate boilers

ID fanFD fan
PositionAfter ESP, two fans in parallelBefore the air heater and grate zones
What it handlesLarge wet flue gas flow, low dustAmbient air
Temperature at the fan140 to 170°CAmbient, 25 to 45°C
Main design concernEfficiency and parallel operationEven air along a wide grate
ControlFurnace draft, VFDs on both fansSteam pressure with oxygen trim

See also the Induced Draft (ID) Fan for bagasse travelling grate boilers.

Questions buyers ask

How much air does the FD fan supply on a bagasse travelling grate boiler?

Typically 40 to 60% of the total combustion air is supplied under the grate by the FD fan. The rest is overfire or secondary air and distributor air, from separate fans at higher pressure. The split depends on the grate design, bagasse fineness and how much of the fuel burns in suspension before reaching the grate.

Does the FD fan on a bagasse boiler need two fans?

Larger boilers, typically above about 60 to 80 TPH, often use two FD fans in parallel so the boiler can continue at reduced load if one is out of service. Smaller boilers commonly use a single fan with a robust motor and a well-maintained bearing arrangement. The choice depends on how much a boiler trip costs the mill.

Why does undergrate air pressure drop at part load?

With a fixed speed fan and damper control, plenum pressure falls as dampers close and the fan moves along its curve. Air then favours the zones nearest the duct inlet. Controlling FD fan speed to hold plenum pressure keeps air even along the grate at all loads, and the zone dampers then only set the split.

Information needed to quote an FD fan for bagasse travelling grate boilers

  1. Duty point. Combustion air quantity in m³/h or kg/h and the static pressure at the fan outlet, with the margins you want.
  2. Air condition. Site ambient temperature range and altitude, and whether the fan takes ambient air or air already heated.
  3. System. Boiler or furnace capacity and fuel, resistance of the air heater, windbox, grate or burner, and the existing fan curve or nameplate if this is a replacement.
  4. Mechanical. Drive arrangement, flow control (damper, inlet vanes or variable speed drive), noise limit, rotation and discharge orientation.
  5. Air split. Shares of undergrate, secondary and distributor air in the design.
  6. Grate zones. Number of undergrate compartments and design plenum pressure.

Built and tested in Chennai

Adroit Fantech Engineers has designed and manufactured industrial fans at Ayanambakkam, Chennai since 2004. Each impeller, casing and shaft is built for the gas and temperature it will see, performance tested as per IS 4894 or BS 848 Part I, and balanced to grade G 6.3 or G 2.5 as per ISO 21940-11, with the records supplied with the fan. We also replace rotors and retrofit existing fans of any make.

FD Fan for related applications

Industries

Services on this fan

FD Fan for bagasse travelling grate boilers: send us your duty point

Flow, pressure, air temperature and the fuel are enough to start a selection.

Get a quote