The process
Hot blast stoves heat the blast air for the furnace, burning cleaned blast furnace gas with combustion air from dedicated fans. The duty is clean, steady and critical, with dampers switching stoves between heating and blowing.
The gas at the fan
Clean air to the hot blast stoves at steady pressure. A combustion air duty where reliability over long runs is the requirement.
Selection for this duty
| Blade form | Backward curved or aerofoil for the best efficiency on clean gas |
| Material of construction | Mild steel |
| Drive and bearings | Direct coupled or belt driven; belt drive where the duty point may need tuning at site |
| Density at the fan | At about 40°C the gas density is close to 1.13 kg/m³, 94% of standard air. Pressure developed and power drawn fall in the same ratio, so the selection is made at this density and the motor is checked at cold start. |
The fan behind a bag filter, cyclone or multiclone on a dust extraction system. Placed on the clean side where possible so the blade can be chosen for efficiency. Client-stated blade types for the Dust Collector Fan in general: Backward inclined and radial tipped.
Industries
Other fans in blast furnace hot blast stoves
Dust Collector Fan in other processes
Services on this fan
Information needed to select or quote
- Duty point. Volume flow and static pressure at the fan inlet, with the gas density and temperature or the conditions to derive it.
- Operating conditions. Site altitude, normal operating temperature and continuous or intermittent duty.
- Gas stream. Dust loading and particle size, corrosive species, moisture, upset temperature and any tendency of the material to deposit on the impeller.
- Mechanical. Rotation viewed from the drive end, discharge orientation and motor power.