13, Galaxy Road, Ponniamman Nagar, Ayanambakkam, Chennai 600 095 +91 91766 67102  |  +91 91766 67103  |  marketing@adroitfantech.com
Home › Fans by Process › Effluent Treatment and Zero Liquid Discharge Plants

Fans and Air Pollution Control for Effluent Treatment and Zero Liquid Discharge Plants

Zero liquid discharge plants concentrate effluent in MVR evaporators and dry the salt in a dryer.

The process

Zero liquid discharge plants concentrate effluent in MVR evaporators and dry the salt in a dryer. The MVR blower is the heart of the evaporator, the dryer needs a hot air fan, and the odour from the treatment tanks goes to a scrubber.

The gas

Saturated vapour, often with dissolved solids and a low pH. Wetted parts in stainless steel, a shaft seal rated for the vapour, drain points and a casing designed for condensate.

Fans in this process

DutyWhat it does hereType usually selected
MVR BlowerRecompresses the vapour leaving an evaporator so it can be reused as the heating medium.Backward curved
Fume Exhaust SystemHoods, ducting and an exhaust fan that capture fume at source and deliver it to a scrubber, bag filter or stack.Backward inclined and radial tipped
Mist EliminatorSeparates entrained liquid droplets from a vapour or gas stream, ahead of a compressor, a fan or a stack..Demister Knockdown Vessel
Ventilation FanMoves air through a plant or building for fresh air supply, heat removal and fume dilution where the system is ducted.Backward inclined and forward curved
Hot Air FanCirculates or supplies air at elevated temperature to a dryer, oven or kiln.Backward curved and backward inclined

Air pollution control

Industries

Related processes

Send us your duty point

Flow, pressure, gas condition and temperature are enough to start a selection.

Get a quote