Home › Applications › ID Fan › Municipal Solid Waste to Energy Plants

Induced Draft (ID) Fan · designed and built in Chennai

Induced Draft (ID) Fan for Municipal Solid Waste to Energy Plants

The ID fan on an MSW waste to energy plant draws the flue gas through the boiler, scrubber and bag filter and holds the furnace at negative pressure so that no gas escapes the grate. The gas carries HCl and SO₂, so corrosion at low temperature, not dust, decides its design.

Send your duty pointCall +91 91766 67102
140 to 160°C after the scrubber and bag filterGas temperature, normal
0.84 kg/m³Gas density at 150°C
Backward curvedBlade form

How municipal solid waste to energy plants work

A municipal solid waste to energy plant burns mixed household waste, usually on a reciprocating or moving grate, to raise steam for a turbine. Indian MSW is wet and low in heating value, typically 40 to 55% moisture and 1,200 to 2,000 kcal/kg as received, so it is aged in the bunker to drain leachate before firing. The furnace holds the gas above 850°C for at least two seconds. The gas then passes the boiler, often with SNCR for NOx, a semi-dry or dry scrubber using lime and activated carbon for acid gases and dioxins, and a bag filter before the ID fan and stack. Primary air is drawn from the waste bunker hall, which keeps the bunker under suction and controls odour.

Where the ID fan sits

  1. Grate furnace
  2. Boiler and economiser
  3. Semi-dry scrubber
  4. Lime and carbon injection
  5. Bag filter
  6. ID fan
  7. Stack

The fan is the last item before the stack, after the bag filter, so the dust it sees is low. The suction at its inlet covers the furnace draft, the boiler, the scrubber and the bag filter, typically 350 to 550 mmWC. The scrubber cools the gas to 140 to 160°C to make its chemistry work, which leaves the gas only a margin above the acid dew point of HCl and SO₃. Some plants use a wet scrubber after the bag filter, and in that case the fan is placed either before it, on hot dry gas, or after it on saturated gas.

Gas at the ID fan

Gas temperature, normal140 to 160°C after the scrubber and bag filter
Maximum or upsetUp to 220°C on scrubber water failure; 60 to 70°C saturated if after a wet scrubber
Dust at the fanLow, typically below 10 mg/Nm³ of fine salts and lime after the bag filter
Moisture and dew pointWet waste gives 15 to 25% water vapour; acid dew point often 120 to 140°C
Corrosive speciesHCl, SO₂, residual chlorides and hygroscopic calcium chloride from the scrubber
Density at the design temperatureAbout 0.84 kg/m³ at 150°C, 70% of standard air. Pressure developed and power drawn scale with density, so the fan is selected at this condition and the motor is checked at the coldest operating or start-up condition.

ID Fan selection for municipal solid waste to energy plants

Blade formBackward curved, for efficiency on clean, low-dust gas
Material of constructionMild steel with corrosion allowance and an insulated casing on dry duty; SS 316L or duplex stainless after a wet scrubber
Drive and arrangementDirect coupled, arrangement 8, with a gas-tight shaft seal
Bearings and coolingPedestal bearings outside the gas path with a cooling disc
Flow controlVariable speed drive on furnace pressure, with an inlet damper for isolation
Also specifiedFull insulation and cladding, casing drain, and a warm air or recirculation connection to keep the fan dry during shutdown

What this ID fan has to cope with

Acid condensation during shutdown

When the plant stops, the casing cools below the acid dew point and residual gas condenses as dilute hydrochloric and sulphuric acid. Insulation, purging the fan with warm dry air, and a drain at the casing low point stop corrosion pitting between runs.

Hygroscopic deposits

Calcium chloride from the scrubber absorbs moisture and forms a sticky, corrosive paste on blades and inside the casing if the gas temperature drops. Keeping the gas above its dew point and cleaning doors for inspection avoid both imbalance and corrosion under deposits.

Variable waste and furnace pressure

Waste calorific value changes hour by hour, and wet loads cause sudden steam and gas volume changes. The fan responds quickly through speed control to hold the furnace negative and prevent fugitive emissions at the feed chute. The fan is sized for the wettest and the richest waste in the design range.

Energy and control

MSW plants run continuously at a set steam output, but gas volume varies with waste moisture and excess air. An ID fan on variable speed control follows furnace pressure directly and avoids the losses of a throttled damper. Since auxiliary power is a large share of gross output on small MSW units, a fan selected close to the real duty point noticeably improves net export.

ID fan and FD fan in municipal solid waste to energy plants

ID fanFD fan
PositionAfter the bag filter, before the stackBunker hall intake, ahead of the air preheater
What it handlesCleaned flue gas with HCl and SO₂Humid, odorous bunker air
Temperature at the fan140 to 160°C30 to 45°C
Main design concernAcid corrosion below dew pointFouling by light waste and moisture
ControlFurnace pressurePrimary air flow by grate zone

See also the Forced Draft (FD) Fan for municipal solid waste to energy plants.

Questions buyers ask

What material is used for an ID fan in a waste to energy plant?

On dry duty after a bag filter at 140 to 160°C, mild steel with corrosion allowance and good insulation is common. Where the fan follows a wet scrubber and handles saturated gas, SS 316L or duplex stainless is used. The inlet box, which runs coldest, is often upgraded first.

Why does the ID fan corrode in an MSW incineration plant?

Mostly during shutdowns. The gas contains HCl and SO₂, and when the fan cools below the acid dew point the condensate is strongly acidic. Calcium chloride deposits also attract moisture. Keeping the fan warm and dry when stopped is the main protection. Water washing must be followed by thorough drying.

Where is the ID fan placed in an MSW plant?

Normally after the bag filter and before the stack, so it handles cleaned gas and keeps the whole system under suction. Where a wet scrubber is added, the fan may be before or after it, which changes the material choice. It is the last item in the gas cleaning train.

Information needed to quote an ID fan for municipal solid waste to energy plants

  1. Duty point. Gas volume in m³/h or Am³/h at the fan inlet and the static pressure the fan must develop, with the margin you want on each.
  2. Gas condition. Normal and maximum gas temperature at the fan, dust loading after the collector, moisture and any acid gases such as SO₂ or HCl.
  3. System. Boiler or furnace capacity and fuel, collector type and its pressure drop, and the existing fan curve or nameplate if this is a replacement.
  4. Mechanical. Drive arrangement, flow control (damper, inlet vanes or variable speed drive), rotation and discharge orientation, and a layout drawing or site photograph.
  5. Gas cleaning train. Scrubber type, sorbents used, and whether the fan is before or after any wet stage.
  6. Acid gas loading. Raw gas HCl and SO₂ concentrations and the gas temperature leaving the scrubber.

Built and tested in Chennai

Adroit Fantech Engineers has designed and manufactured industrial fans at Ayanambakkam, Chennai since 2004. Each impeller, casing and shaft is built for the gas and temperature it will see, performance tested as per IS 4894 or BS 848 Part I, and balanced to grade G 6.3 or G 2.5 as per ISO 21940-11, with the records supplied with the fan. We also replace rotors and retrofit existing fans of any make.

ID Fan for related applications

Industries

Services on this fan

ID Fan for municipal solid waste to energy plants: send us your duty point

Flow, pressure, gas temperature and the fuel are enough to start a selection.

Get a quote