Induced Draft (ID) Fan · designed and built in Chennai

Induced Draft (ID) Fan for Khandsari Sugar Plant Furnaces

The ID fan on a khandsari sugar plant furnace draws flue gas under a long train of open pans and delivers it to the chimney. The long flue, the wet bagasse and round-the-clock running make draft reliability, fly ash and moisture the main concerns, rather than the high temperatures of a jaggery unit.

Send your duty pointCall +91 91766 67102
180 to 280°C after the last panGas temperature, normal
0.69 kg/m³Gas density at 240°C
Radial or backward inclinedBlade form

How khandsari sugar plant furnaces work

A khandsari unit makes open-pan sugar on a larger scale than jaggery, typically from 100 to 500 tonnes of cane a day. Juice is clarified, often by sulphitation or with hydros and lime, and concentrated in a train of five to seven open pans set in series over a long furnace fired with bagasse straight from the mill. The concentrated syrup is crystallised in coolers and spun in centrifugals. The flue gas passes under each pan in turn, so it leaves cooler than in a jaggery unit, typically 180 to 280°C. The bagasse is burnt wet, about 45 to 50% moisture, on a step or inclined grate, and the units run around the clock through the crushing season.

Where the ID fan sits

  1. Step grate
  2. Under the pan train
  3. Last pan flue
  4. Settling chamber or cyclone
  5. ID fan
  6. Chimney

The fan sits at the end of the long flue under the pan train, after a settling chamber or cyclone. The flue is often 20 to 40 metres long, with several bends, so the resistance is higher than in a jaggery unit and the suction at the fan is typically 50 to 120 mmWC. The fan replaces or supplements a tall brick chimney.

Gas at the ID fan

Gas temperature, normal180 to 280°C after the last pan
Maximum or upsetAbout 350°C if a pan is out of service
Dust at the fanBagasse fly ash and unburnt fibre; higher with wet bagasse
Moisture and dew pointHigh from wet bagasse; water vapour 15 to 25% by volume
Corrosive speciesLow; condensation possible at start-up
Density at the design temperatureAbout 0.69 kg/m³ at 240°C, 58% of standard air. Pressure developed and power drawn scale with density, so the fan is selected at this condition and the motor is checked at the coldest operating or start-up condition.

ID Fan selection for khandsari sugar plant furnaces

Blade formRadial or backward inclined, robust for fly ash
Material of constructionMild steel with wear plate at blade tips
Drive and arrangementBelt driven or direct coupled with a cooling disc
Bearings and coolingBearings away from the casing with a cooling disc
Flow controlVariable speed drive or damper on furnace draft
Also specifiedSettling chamber or cyclone before the fan, and an inspection door

What this ID fan has to cope with

Wet bagasse and fly ash

Burning wet bagasse produces more fly ash and unburnt fibre, carried a long way through the flue. Without a settling chamber or cyclone, the fan erodes and the chimney emits heavy smoke. A collector before the fan and wear plate on the blades extend fan life.

Draft in a long flue

The long flue under the pan train has many bends and leaks, and natural draft varies with weather. A fan with enough suction margin, and good sealing of the flue, keep every pan boiling steadily.

Continuous running

Khandsari units run round the clock through the season, and a fan failure stops the pans and spoils the batch. Robust bearings, monitoring and a spare rotor or standby fan reduce the risk.

Energy and control

Khandsari units run for 100 to 150 days a year, continuously. A variable speed drive on the ID fan, set on furnace draft, saves power when the crushing rate is lower. Reducing air leaks into the long flue reduces the gas volume the fan handles and improves the heat available to the pans.

ID fan and FD fan in khandsari sugar plant furnaces

ID fanFD fan
PositionEnd of the long flue, before the chimneyBeside the furnace, under the step grate
What it handlesMoist gas with bagasse fly ashAmbient air
Temperature at the fan180 to 280°CAmbient
Main design concernSteady draft, fly ash and continuous dutyAir through a deep wet bed
ControlFurnace draftCrushing rate

See also the Forced Draft (FD) Fan for khandsari sugar plant furnaces.

Questions buyers ask

How is a khandsari furnace different from a jaggery furnace?

A khandsari unit is larger, runs continuously, and has a longer train of pans, so the flue is longer and the gas leaves cooler. It often burns wet bagasse straight from the mill, which gives more fly ash and moisture.

Does a khandsari unit need an ID fan?

Many use a tall chimney, but an ID fan gives steady draft through the long flue regardless of weather, and allows better control of the firing. It is common in larger and modernised units.

What temperature is the flue gas in a khandsari furnace?

Typically 180 to 280°C after the last pan. It can reach about 350°C if a pan is out of service or the flue is short-circuited.

Information needed to quote an ID fan for khandsari sugar plant furnaces

  1. Duty point. Gas volume in m³/h or Am³/h at the fan inlet and the static pressure the fan must develop, with the margin you want on each.
  2. Gas condition. Normal and maximum gas temperature at the fan, dust loading after the collector, moisture and any acid gases such as SO₂ or HCl.
  3. System. Boiler or furnace capacity and fuel, collector type and its pressure drop, and the existing fan curve or nameplate if this is a replacement.
  4. Mechanical. Drive arrangement, flow control (damper, inlet vanes or variable speed drive), rotation and discharge orientation, and a layout drawing or site photograph.
  5. Unit size. Cane crushed per day, number of pans and the flue length.
  6. Bagasse. Bagasse moisture and quantity burnt per hour.

Built and tested in Chennai

Adroit Fantech Engineers has designed and manufactured industrial fans at Ayanambakkam, Chennai since 2004. Each impeller, casing and shaft is built for the gas and temperature it will see, performance tested as per IS 4894 or BS 848 Part I, and balanced to grade G 6.3 or G 2.5 as per ISO 21940-11, with the records supplied with the fan. We also replace rotors and retrofit existing fans of any make.

ID Fan for related applications

Industries

Services on this fan

ID Fan for khandsari sugar plant furnaces: send us your duty point

Flow, pressure, gas temperature and the fuel are enough to start a selection.

Get a quote